Medical radiological procedures: which information would be chosen for the report?
Adult
Age Factors
Child
European Union
Humans
Medical Records
/ legislation & jurisprudence
Patient Education as Topic
/ legislation & jurisprudence
Radiation Dosage
Radiation Exposure
/ legislation & jurisprudence
Radiation, Ionizing
Radiology
/ legislation & jurisprudence
Radiometry
Reference Values
Relative Biological Effectiveness
Risk Management
/ legislation & jurisprudence
Dose index
EU Directive 2013/59 transposition
Patient exposure information
Radiological equipment
Radiological report
Journal
La Radiologia medica
ISSN: 1826-6983
Titre abrégé: Radiol Med
Pays: Italy
ID NLM: 0177625
Informations de publication
Date de publication:
Aug 2019
Aug 2019
Historique:
received:
23
11
2018
accepted:
26
03
2019
pubmed:
12
4
2019
medline:
26
9
2019
entrez:
12
4
2019
Statut:
ppublish
Résumé
The aim of this study was to properly define the information regarding patient exposure to Ionizing Radiations in the radiological report, according to the European Directive 2013/59/EURATOM (EU 2013/59 art.58(b)). For this purpose, we evaluated the results from other Member States EU 2013/59 transpositions and from Guidelines recommendation published by International Organizations involved in diagnostic radiology. A practical way for implementing art.58 is also traced. Dosimetric quantities, such as exposure, absorbed dose and effective dose which may be included in radiological report, were first analyzed; then, in order to define international state of art of Member States EU 2013/59 transposition, a Web research using French, English, Spanish and German key words was performed. EU 2013/59 transposition for 5 Member States was reported. Especially regarding art.58, a European project reports that few European countries (11 of 28) have identified the dose metrics to be used in radiological report. Scientific organizations supporting clinical radiologists and medical physicists have published Guidelines reporting parameters useful to quantify the radiation output and to assess patient dose. Our research revealed that there is not a shared interpretation of patient exposure information to be included in radiological report. Nevertheless, according to scientific community, authors believe that the exposure is the most appropriate information that could be included in radiological report. Alternatively, but with more expensiveness, a risk index based on effective dose could be used. Moreover, the systematic exposure information recorded could be useful for dose estimates of population from medical exposure.
Identifiants
pubmed: 30972532
doi: 10.1007/s11547-019-01032-w
pii: 10.1007/s11547-019-01032-w
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
783-793Références
OECD Obs. 1985 Sep;(136):9-12
pubmed: 12267642
Rofo. 2002 Dec;174(12):1570-6
pubmed: 12471531
Ann ICRP. 2007;37(2-4):1-332
pubmed: 18082557
Ann ICRP. 1991;21(1-3):1-201
pubmed: 2053748
Radiol Med. 2012 Mar;117(2):312-21
pubmed: 22228133
Radiol Med. 2014 Oct;119(10):803-10
pubmed: 24599754
Radiol Med. 2016 Feb;121(2):144-52
pubmed: 26387096
J Korean Med Sci. 2016 Feb;31 Suppl 1:S45-54
pubmed: 26908988
J Appl Clin Med Phys. 2017 Jul;18(4):12-22
pubmed: 28497529
Radiol Med. 2018 Oct;123(10):788-798
pubmed: 29856001