CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND.
Aged
Aortic Valve
/ surgery
Atrioventricular Node
/ pathology
Cardiology
/ methods
Coronary Angiography
Electrophysiology
Female
Finland
Fluoroscopy
Humans
Male
Middle Aged
Percutaneous Coronary Intervention
Radiation Dosage
Radiography, Interventional
/ methods
Radiology, Interventional
/ methods
Radiometry
Reference Values
Tachycardia
/ pathology
Journal
Radiation protection dosimetry
ISSN: 1742-3406
Titre abrégé: Radiat Prot Dosimetry
Pays: England
ID NLM: 8109958
Informations de publication
Date de publication:
31 Dec 2019
31 Dec 2019
Historique:
received:
21
12
2018
revised:
01
02
2019
accepted:
26
03
2019
pubmed:
17
4
2019
medline:
29
7
2020
entrez:
17
4
2019
Statut:
ppublish
Résumé
The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm2) and PCIs (KAP 75 cm2), and novel levels for PIs (KAP 3.5 Gycm2), atrial fibrillation ablation procedures (KAP 25 Gycm2) and TAVI (KAP 90 Gycm2). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm2), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm2) and atrial flutter procedures (KAP 16 Gycm2). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.
Identifiants
pubmed: 30989216
pii: 5466141
doi: 10.1093/rpd/ncz041
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
483-493Informations de copyright
© The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.