Field-amplified sample injection and sweeping micellar electrokinetic chromatography in analysis of glyphosate and aminomethylphosphonic acid in wheat.


Journal

Journal of chromatography. A
ISSN: 1873-3778
Titre abrégé: J Chromatogr A
Pays: Netherlands
ID NLM: 9318488

Informations de publication

Date de publication:
13 Sep 2019
Historique:
received: 12 03 2019
revised: 23 04 2019
accepted: 10 05 2019
pubmed: 21 5 2019
medline: 26 7 2019
entrez: 21 5 2019
Statut: ppublish

Résumé

Glyphosate, a widely used herbicide, has been classified as probably carcinogenic to humans by the International Agency for Research on Cancer (IARC). In the present study a method based on Field-Amplified Sample Injection and Sweeping Micellar Electrokinetic Chromatography (FASI sweep-MEKC) has been developed and validated for determination of glyphosate and its microbial metabolite aminomethylphosphonic acid (AMPA) in wheat flour. The method involved a preliminary solid phase extraction for cleanup of the aqueous extracts from wheat flour, based sequentially on C18 and strong anion exchange cartridges, followed by derivatization using 9-fluorenylmethylchloroformate. Optimization of sample cleanup and derivatization procedure was carried out by a HPLC-UV method, whereas FASI sweep-MEKC was applied for achieving the sensitivity necessary for analysis of real samples. To this regard, optimum conditions involved the use of an extended path fused-silica capillary (80 cm total length, 50 μm, i.d.) filled with a high concentration buffer (sodium phosphate 100 mM, pH 2.2). Electrokinetic sampling was carried out at -10 kV with injection time of 700 s and the separation of the loaded analytes was performed under MEKC conditions using sodium phosphate buffer 50 mM at pH 2.2, supplemented with sodium dodecyl sulfate, 100 mM. The method was validated for linearity, precision, accuracy and sensitivity, showing that using conventional UV detection (210 nm) the achieved limit of quantitation (LOQ) values for both the analytes were widely lower than those set by Authorities. In particular, LOQ for glyphosate and AMPA were found to be 5 and 2.5 ng/mL, respectively, corresponding to 0.1 and 0.05 mg/kg, in wheat flour. The method, applied to commercially available real samples (wheat flour from different manufacturers) and to an experimental sample obtained by cv. Svevo wheat, can be considered as a convenient alternative to the existing approaches in analysis of complex matrices.

Identifiants

pubmed: 31104848
pii: S0021-9673(19)30519-9
doi: 10.1016/j.chroma.2019.05.013
pii:
doi:

Substances chimiques

Isoxazoles 0
Organophosphorus Compounds 0
Tetrazoles 0
Water 059QF0KO0R
1-aminomethylphosphonic acid 1066-51-9
Sodium Dodecyl Sulfate 368GB5141J
2-amino-3-(3-hydrox-5(2-methyl-2H-tetrazol-5-yl)isoxazol-4-yl)propionic acid J090588E6X
Glycine TE7660XO1C

Types de publication

Journal Article

Langues

eng

Pagination

357-364

Informations de copyright

Copyright © 2019 Elsevier B.V. All rights reserved.

Auteurs

Roberto Gotti (R)

Department of Pharmacy and Biotechnology, University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy. Electronic address: roberto.gotti@unibo.it.

Jessica Fiori (J)

Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.

Sara Bosi (S)

Department of Agricultural and Food Sciences, University of Bologna, Viale Fanin 44, 40127 Bologna, Italy.

Giovanni Dinelli (G)

Department of Agricultural and Food Sciences, University of Bologna, Viale Fanin 44, 40127 Bologna, Italy.

Articles similaires

Animals Dietary Fiber Dextran Sulfate Mice Disease Models, Animal
Silicon Dioxide Water Hot Temperature Compressive Strength X-Ray Diffraction
Triticum Transcription Factors Gene Expression Regulation, Plant Plant Proteins Salt Stress
1.00
Oryza Agricultural Irrigation Potassium Sodium Soil

Classifications MeSH