An Energy Efficient Multi-User Asynchronous Wireless Transmitter for Biomedical Signal Acquisition.


Journal

IEEE transactions on biomedical circuits and systems
ISSN: 1940-9990
Titre abrégé: IEEE Trans Biomed Circuits Syst
Pays: United States
ID NLM: 101312520

Informations de publication

Date de publication:
08 2019
Historique:
pubmed: 21 5 2019
medline: 17 1 2020
entrez: 21 5 2019
Statut: ppublish

Résumé

The paper presents a novel transmitter architecture for short-range asynchronous wireless communication, applicable to simultaneous multi-user wireless acquisition of biological signals. The analog signal, provided from an analog biosensor, is transformed to time information using an Integral Pulse Frequency Modulator (IPFM) as a Time-Encoding Machine. The IPFM generates a time-encoded unipolar pulse train, maintaining the linear dependence of the output pulse distance on analog input voltage. The system enables continuous acquisition of the signals from multiple sensors in which each transmitter has unique feedback loop delay used for multi-user coding. IPFM pulses trigger the Impulse Radio Ultra-Wideband pulse generator directly, providing two ultra-wideband (UWB) pulses per each IPFM pulse. Due to the lack of internal clock signal and microprocessor-free multi-user coding, the circuitry satisfies the requirements of multi-user coding energy efficiency and size reduction, which are crucial demands in biomedical applications. The proposed Time-Encoded UWB (TE-UWB) transmitter is implemented in 0.18 [Formula: see text] CMOS technology. Measurement results of the IPFM transfer function for input voltage ranging from 0.15 to 1.5 V are presented, providing the dependence of the IPFM pulse time distance on analog input voltage and power consumption dependence on the input voltage level. For continuous monitoring operation, total power consumption of the transmitter circuitry for the maximum input voltage is 10.8 [Formula: see text], while for the lowest input voltage it increases to 40.48 [Formula: see text]. The circuit occupies 0.14 [Formula: see text].

Identifiants

pubmed: 31107660
doi: 10.1109/TBCAS.2019.2917690
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

619-630

Auteurs

Articles similaires

Humans Meta-Analysis as Topic Sample Size Models, Statistical Computer Simulation
Humans Algorithms Software Artificial Intelligence Computer Simulation
Humans Robotic Surgical Procedures Clinical Competence Male Female

A computational model for bacteriophage ϕX174 gene expression.

Alexis M Hill, Tanvi A Ingle, Claus O Wilke
1.00
Gene Expression Regulation, Viral Promoter Regions, Genetic Bacteriophage phi X 174 Computer Simulation Models, Genetic

Classifications MeSH