Analytical validation of an Enzyme Immunoassay for the measurement of urinary oxytocin in dogs and wolves.
Analytical validation
Canis lupus
Canis lupus familiaris
Degradation
Immunogram
Repeatability
Storage
Journal
General and comparative endocrinology
ISSN: 1095-6840
Titre abrégé: Gen Comp Endocrinol
Pays: United States
ID NLM: 0370735
Informations de publication
Date de publication:
15 09 2019
15 09 2019
Historique:
received:
14
08
2018
revised:
23
04
2019
accepted:
18
05
2019
pubmed:
24
5
2019
medline:
18
12
2019
entrez:
24
5
2019
Statut:
ppublish
Résumé
Assessing changes in oxytocin (OT) levels in response to a variety of social stimuli has become of major interest in the field of behavioral endocrinology. OT is involved in the regulation of various aspects of social behavior such as tolerance, and the formation and maintenance of social bonds but also the regulation of stress. All of these aspects have been identified as potential targets of selection during the domestication process. Therefore, comparing the role of the oxytocinergic system in various aspects of dog and wolf social behavior, might help to understand whether this system was involved in the domestication process. Studies assessing OT levels in dogs and wolves have used invasively collected plasma and serum samples and non-invasively collected urine samples. However, when using an assay system on a new species a careful and complete validation of the method is of crucial importance, and to date no proper validation, to assess urinary OT levels in dogs and wolves, has been reported. We therefore conducted an analytical validation of an Enzyme Immunoassay (EIA) for the measurement of OT in urine of dogs and wolves, using a commercially available EIA. Stability tests revealed that OT levels degrade over time when stored at 4 °C, but are little affected by repeated thawing. In addition, our results indicate that the variance in OT levels is slightly lower when phosphoric acid is added following collection to prevent OT degradation. Long term storage tests revealed that urinary OT levels are least variable when stored as extracts in ethanol at -20 °C, rather than as unextracted urine samples. Validation results were acceptable with regard to parallelism, but values for accuracy and extraction efficiency were not meeting the standard criteria usually applied to steroid EIAs, especially when assessed for the lower range of the assay. The results of this study highlight the importance of an analytical assay validation, since even if validation parameters are not optimal, if published, they allow readers to estimate the relevance of studies using the validated method.
Identifiants
pubmed: 31121163
pii: S0016-6480(18)30447-7
doi: 10.1016/j.ygcen.2019.05.015
pii:
doi:
Substances chimiques
Oxytocin
50-56-6
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Validation Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
73-82Informations de copyright
Copyright © 2019 Elsevier Inc. All rights reserved.