Assessment of deep inspiration breath hold technique setup reproducibility using mega voltage imaging for left breast cancer radiation therapy-integrated network study.
DIBH
Left breast cancer
MV imaging
Set up reproducibility
Visual feedback
Journal
Medical dosimetry : official journal of the American Association of Medical Dosimetrists
ISSN: 1873-4022
Titre abrégé: Med Dosim
Pays: United States
ID NLM: 8908862
Informations de publication
Date de publication:
Historique:
received:
10
09
2018
revised:
20
01
2019
accepted:
29
04
2019
pubmed:
4
6
2019
medline:
15
12
2020
entrez:
3
6
2019
Statut:
ppublish
Résumé
We evaluated daily setup reproducibility of deep inspiration breath hold (DIBH) using mega voltage (MV) imaging for left breast cancer radiation therapy. Analysis of 109 left breast cancer patients across UPMC Hillman Cancer Center network treated using DIBH technique with daily MV imaging was done. Patient characteristics, MV imaging procedure used and inter-fraction directional shifts were collected. For the statistical analyses, we separated all patients into 2 groups in each of the following 3 categories; (1) obese (BMI ≥ 30) vs nonobese, (2) mastectomy vs lumpectomy, (3) internal mammary node (IMN) treatment vs no IMN treatment. The group mean inter-fraction directional shifts were as following: (1) 0.7 mm (superior), 0.8 mm (inferior); (2) 0.65 mm (left), 0.64 mm (right); (3) 0.89 mm (anterior), 0.83 mm (posterior). Also, any directional shift ≥ 2 mm, ≥ 3 mm, ≥ 4 mm, ≥ 5 mm, ≥ 10 mm was found to be 52.9%, 37.6%, 30.9%, 21.9%, 3.7% of total fractions, respectively. In the stratified analysis, obese patients had larger directional shifts (p < 0.05) and highly associated with number of fractions for ≥ 5 mm in any directional shift compared to nonobese patients (29% vs 17%; p = 0.04). DIBH setup for left breast cancer treatment at our large cancer center network was reproducible with any mean directional shifts less than 1.0 mm using MV imaging. Daily imaging would be more beneficial for obese patients compared to nonobese patients.
Identifiants
pubmed: 31153678
pii: S0958-3947(19)30059-7
doi: 10.1016/j.meddos.2019.04.006
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
28-33Informations de copyright
Copyright © 2019 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Conflicts of interest The authors declare no conflicts of interest.