Best Tourniquet Holding and Strap Pulling Technique.


Journal

Journal of special operations medicine : a peer reviewed journal for SOF medical professionals
ISSN: 1553-9768
Titre abrégé: J Spec Oper Med
Pays: United States
ID NLM: 101158402

Informations de publication

Date de publication:
2019
Historique:
accepted: 01 06 2019
entrez: 16 6 2019
pubmed: 16 6 2019
medline: 28 8 2019
Statut: ppublish

Résumé

Appropriate strap pressure before tightening-system use is an important aspect of nonelastic, limb tourniquet application. Using different two-handed techniques, the strap of the Generation 7 Combat Application Tourniquet (C-A-T7), Tactical Ratcheting Medical Tourniquet (Tac RMT), Tactical Mechanical Tourniquet (TMT), Parabelt, and Generation 3 SOF® Tactical Tourniquet-Wide (SOFTTW) was secured mid-thigh by 20 appliers blinded to pressure data and around a thigh-sized ballistic gel cylinder by gravity and 23.06kg. Pulling only outward (90° to strap entering buckle) achieved the lowest secured pressures on thighs and gel. For appliers, the best holding location was above the buckle, and the best strap-pulling direction was tangential to the thigh or gel (0° to strap entering buckle). Preceding tangential pulling with outward pulling resulted in higher secured pressures on the gel but did not aid appliers. Appliers generally did not reach secured pressures achievable for their strength. Of 80 thigh applications per tourniquet, 77 C-A-T7, 41 Tac RMT, 35 TMT, 16 Parabelt, and 10 SOFTTW applications had secured pressures greater than 100mmHg. The default for best tourniquet strap-application technique is to hold above the buckle and pull the strap tangential to the limb at the buckle. Additionally, neither strength nor experience guarantees desirable strap pressures in the absence of pressure knowledge.

Sections du résumé

BACKGROUND BACKGROUND
Appropriate strap pressure before tightening-system use is an important aspect of nonelastic, limb tourniquet application.
METHODS METHODS
Using different two-handed techniques, the strap of the Generation 7 Combat Application Tourniquet (C-A-T7), Tactical Ratcheting Medical Tourniquet (Tac RMT), Tactical Mechanical Tourniquet (TMT), Parabelt, and Generation 3 SOF® Tactical Tourniquet-Wide (SOFTTW) was secured mid-thigh by 20 appliers blinded to pressure data and around a thigh-sized ballistic gel cylinder by gravity and 23.06kg.
RESULTS RESULTS
Pulling only outward (90° to strap entering buckle) achieved the lowest secured pressures on thighs and gel. For appliers, the best holding location was above the buckle, and the best strap-pulling direction was tangential to the thigh or gel (0° to strap entering buckle). Preceding tangential pulling with outward pulling resulted in higher secured pressures on the gel but did not aid appliers. Appliers generally did not reach secured pressures achievable for their strength. Of 80 thigh applications per tourniquet, 77 C-A-T7, 41 Tac RMT, 35 TMT, 16 Parabelt, and 10 SOFTTW applications had secured pressures greater than 100mmHg.
CONCLUSIONS CONCLUSIONS
The default for best tourniquet strap-application technique is to hold above the buckle and pull the strap tangential to the limb at the buckle. Additionally, neither strength nor experience guarantees desirable strap pressures in the absence of pressure knowledge.

Identifiants

pubmed: 31201751
doi: 10.55460/H9GT-Q602
doi:
pii:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

48-56

Informations de copyright

2019.

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH