Antibiotic-loaded ceramic sternum for sternal replacement in a patient with deep sternal wound infection.
Alumina
Antibiotic loaded
Deep sternal wound infection
Mediastinitis
Pulmonary function tests
Sternum
Journal
Interactive cardiovascular and thoracic surgery
ISSN: 1569-9285
Titre abrégé: Interact Cardiovasc Thorac Surg
Pays: England
ID NLM: 101158399
Informations de publication
Date de publication:
01 12 2019
01 12 2019
Historique:
received:
24
04
2019
revised:
27
06
2019
accepted:
30
06
2019
pubmed:
1
8
2019
medline:
14
4
2020
entrez:
1
8
2019
Statut:
ppublish
Résumé
A 68-year-old man presented with destruction of his sternum after cardiac surgery. Classical management with multiple debridements, vacuum dressings and antibiotics failed. A replacement of his sternum was performed using an antibiotic-loaded porous alumina ceramic sternum. Despite the infected wound, the ceramic sternum did not get infected due to the high antibiotic concentration obtained locally. Two years after the surgery, no relapse occurred and the pulmonary function tests improved.
Identifiants
pubmed: 31365090
pii: 5542086
doi: 10.1093/icvts/ivz182
doi:
Substances chimiques
Anti-Bacterial Agents
0
Coated Materials, Biocompatible
0
Types de publication
Case Reports
Journal Article
Validation Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
973-975Informations de copyright