Adaptive step size algorithm to increase efficiency of proton macro Monte Carlo dose calculation.
Dose calculation
Macro Monte Carlo
Proton therapy
Journal
Radiation oncology (London, England)
ISSN: 1748-717X
Titre abrégé: Radiat Oncol
Pays: England
ID NLM: 101265111
Informations de publication
Date de publication:
09 Sep 2019
09 Sep 2019
Historique:
received:
01
05
2019
accepted:
21
08
2019
entrez:
11
9
2019
pubmed:
11
9
2019
medline:
15
2
2020
Statut:
epublish
Résumé
To provide fast and accurate dose calculation in voxelized geometries for proton radiation therapy by implementing an adaptive step size algorithm in the proton macro Monte Carlo (pMMC) method. The in-house developed local-to-global MMC method for proton dose calculation is extended with an adaptive step size algorithm for efficient proton transport through a voxelized geometry by sampling transport parameters from a pre-simulated database. Adaptive choice of an adequate slab size in dependence of material interfaces in the proton's longitudinal and lateral vicinity is investigated. The dose calculation algorithm is validated against the non-adaptive pMMC and full MC simulation for pencil and broad beams with various energies impinging on academic phantoms as well as a head and neck patient CT. For material interfaces perpendicular to a proton's direction, choice of nearest neighbor slab thickness shows best trade-off between dosimetric accuracy and calculation efficiency. Adaptive reduction of chosen slab size is shown to be required for material interfaces closer than 0.5 mm in lateral direction. For the academic phantoms, dose differences of within 1% or 1 mm compared to full Geant4 MC simulation are found, while achieving an efficiency gain of up to a factor of 5.6 compared to the non-adaptive algorithm and 284 compared to Geant4. For the head and neck patient CT, dose differences are within 1% or 1 mm with an efficiency gain factor of up to 3.4 compared to the non-adaptive algorithm and 145 compared to Geant4. An adaptive step size algorithm for proton macro Monte Carlo was implemented and evaluated. The dose calculation provides the accuracy of full MC simulations, while achieving an efficiency gain factor of three compared to the non-adaptive algorithm and two orders of magnitude compared to full MC for a complex patient CT.
Identifiants
pubmed: 31500647
doi: 10.1186/s13014-019-1362-5
pii: 10.1186/s13014-019-1362-5
pmc: PMC6734301
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
165Références
Phys Med Biol. 2000 Feb;45(2):459-78
pubmed: 10701515
Phys Med Biol. 2005 Mar 7;50(5):1001-10
pubmed: 15798272
Med Phys. 2007 Apr;34(4):1506-13
pubmed: 17500481
Phys Med Biol. 2008 Sep 7;53(17):4825-53
pubmed: 18701772
Phys Med Biol. 2009 Jan 7;54(1):N21-8
pubmed: 19075361
Phys Med Biol. 2010 Aug 21;55(16):4577-88
pubmed: 20668339
Phys Med Biol. 2012 Jun 7;57(11):R99-117
pubmed: 22571913
Phys Med Biol. 2012 Jun 7;57(11):3281-93
pubmed: 22572154
J Med Signals Sens. 2011 Jan;1(1):73-86
pubmed: 22606661
Med Phys. 2012 Nov;39(11):6818-37
pubmed: 23127075
Phys Med Biol. 2012 Dec 7;57(23):7783-97
pubmed: 23128424
Phys Med Biol. 2013 Apr 7;58(7):2027-44
pubmed: 23458969
Phys Med Biol. 2014 Aug 7;59(15):4007-31
pubmed: 24990623
Med Phys. 2015 Jan;42(1):479-90
pubmed: 25563287
Med Phys. 2015 Jun;42(6):2967-78
pubmed: 26127050
Phys Med Biol. 2017 Sep 12;62(19):7598-7616
pubmed: 28809759
Phys Med Biol. 1995 Apr;40(4):543-74
pubmed: 7610114
Med Phys. 1998 May;25(5):656-61
pubmed: 9608475