A direct metal laser sintering (DMLS) root analogue implant placed in the anterior maxilla. Case report.
Computer-Aided Design
/ instrumentation
Cone-Beam Computed Tomography
Dental Implant-Abutment Design
Dental Implants, Single-Tooth
Dental Prosthesis Design
/ instrumentation
Esthetics
Humans
Imaging, Three-Dimensional
Immediate Dental Implant Loading
Incisor
/ injuries
Lasers
Male
Maxilla
Metallurgy
/ instrumentation
Middle Aged
Titanium
Tooth Fractures
/ surgery
Tooth Root
/ injuries
Journal
Annali italiani di chirurgia
ISSN: 2239-253X
Titre abrégé: Ann Ital Chir
Pays: Italy
ID NLM: 0372343
Informations de publication
Date de publication:
05 Mar 2019
05 Mar 2019
Historique:
entrez:
19
9
2019
pubmed:
19
9
2019
medline:
12
3
2020
Statut:
epublish
Résumé
Modern cone beam computed tomography (CBCT) acquisition and three-dimensional (3D) image processing, combined with direct metal laser sintering (DMLS), allows custom-made, root-analogue implants (RAIs). To demonstrate how DMLS permits customized titanium RAI production, with immediate insertion and restoration in a fresh extraction socket of the anterior maxilla. A titanium RAI perfect copy of the radicular unit needed for replacement was created by customized DMLS, and inserted into a fresh extraction socket of the esthetic area of the anterior maxilla. Follow-up after 1 year: the DMLS RAI implant showed a satisfactory functional and esthetic integration, with no bone resorption or soft tissue recessions. The production of customized DMLS RAIs opens new interesting perspectives for immediate implantation. Direct metal laser sintering, Root analogue implant. L’acquisizione della tomografia computerizzata a fascio conico (CBCT) moderna e l’elaborazione tridimensionale (3D) delle immagini, combinata con la sinterizzazione laser diretta (DMLS), consente di realizzare impianti su misura per gli impianti root-analogue (RAI). Lo scopo di questo articolo è quello di dimostrare come la DMLS consente la produzione personalizzata di RAI in titanio, con inserimento e ripristino immediati in un alveolo di recente estrazione dentale del mascellare anteriore. Viene creata da un DMLS personalizzato una copia perfetta RAI in titanio dell’unità radicolare necessaria per la sostituzione, e viene inserita in un alveolo di recente estrazione dentale dall’area estetica del mascellare anteriore. Ad un follow-up di un anno l’impianto DMLS RAI ha mostrato una soddisfacente integrazione funzionale ed estetica, senza riassorbimento osseo o regressione dei tessuti molli. In conclusione la produzione di RAI DMLS personalizzate apre nuove interessanti prospettive per l’impianto dentale immediato.
Sections du résumé
BACKGROUND
BACKGROUND
Modern cone beam computed tomography (CBCT) acquisition and three-dimensional (3D) image processing, combined with direct metal laser sintering (DMLS), allows custom-made, root-analogue implants (RAIs).
PURPOSE
OBJECTIVE
To demonstrate how DMLS permits customized titanium RAI production, with immediate insertion and restoration in a fresh extraction socket of the anterior maxilla.
MATERIALS AND METHODS
METHODS
A titanium RAI perfect copy of the radicular unit needed for replacement was created by customized DMLS, and inserted into a fresh extraction socket of the esthetic area of the anterior maxilla.
RESULTS
RESULTS
Follow-up after 1 year: the DMLS RAI implant showed a satisfactory functional and esthetic integration, with no bone resorption or soft tissue recessions.
CONCLUSIONS
CONCLUSIONS
The production of customized DMLS RAIs opens new interesting perspectives for immediate implantation.
KEY WORDS
BACKGROUND
Direct metal laser sintering, Root analogue implant.
L’acquisizione della tomografia computerizzata a fascio conico (CBCT) moderna e l’elaborazione tridimensionale (3D) delle immagini, combinata con la sinterizzazione laser diretta (DMLS), consente di realizzare impianti su misura per gli impianti root-analogue (RAI). Lo scopo di questo articolo è quello di dimostrare come la DMLS consente la produzione personalizzata di RAI in titanio, con inserimento e ripristino immediati in un alveolo di recente estrazione dentale del mascellare anteriore. Viene creata da un DMLS personalizzato una copia perfetta RAI in titanio dell’unità radicolare necessaria per la sostituzione, e viene inserita in un alveolo di recente estrazione dentale dall’area estetica del mascellare anteriore. Ad un follow-up di un anno l’impianto DMLS RAI ha mostrato una soddisfacente integrazione funzionale ed estetica, senza riassorbimento osseo o regressione dei tessuti molli. In conclusione la produzione di RAI DMLS personalizzate apre nuove interessanti prospettive per l’impianto dentale immediato.
Autres résumés
Type: Publisher
(ita)
L’acquisizione della tomografia computerizzata a fascio conico (CBCT) moderna e l’elaborazione tridimensionale (3D) delle immagini, combinata con la sinterizzazione laser diretta (DMLS), consente di realizzare impianti su misura per gli impianti root-analogue (RAI). Lo scopo di questo articolo è quello di dimostrare come la DMLS consente la produzione personalizzata di RAI in titanio, con inserimento e ripristino immediati in un alveolo di recente estrazione dentale del mascellare anteriore. Viene creata da un DMLS personalizzato una copia perfetta RAI in titanio dell’unità radicolare necessaria per la sostituzione, e viene inserita in un alveolo di recente estrazione dentale dall’area estetica del mascellare anteriore. Ad un follow-up di un anno l’impianto DMLS RAI ha mostrato una soddisfacente integrazione funzionale ed estetica, senza riassorbimento osseo o regressione dei tessuti molli. In conclusione la produzione di RAI DMLS personalizzate apre nuove interessanti prospettive per l’impianto dentale immediato.
Substances chimiques
Titanium
D1JT611TNE
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM