Near-infrared spectroscopy in evaluating psychogenic pseudosyncope-a novel diagnostic approach.


Journal

QJM : monthly journal of the Association of Physicians
ISSN: 1460-2393
Titre abrégé: QJM
Pays: England
ID NLM: 9438285

Informations de publication

Date de publication:
01 Apr 2020
Historique:
received: 13 08 2019
revised: 11 09 2019
pubmed: 10 10 2019
medline: 11 4 2020
entrez: 10 10 2019
Statut: ppublish

Résumé

Psychogenic pseudosyncope (PPS), a conversion disorder and syncope mimic, accounts for a large proportion of 'unexplained syncope'. PPS is diagnosed by reproduction of patients' symptoms during head-up tilt (HUT). Electroencephalogram (EEG), a time consuming and resource intensive technology, is used during HUT to demonstrate absence of cerebral hypoperfusion during transient loss of consciousness (TLOC). Near-infrared spectroscopy (NIRS) is a simple, non-invasive technology for continuous monitoring of cerebral perfusion. We present a series of patients for whom PPS diagnosis was supported by NIRS during HUT. Eight consecutive patients with suspected PPS referred to a syncope unit underwent evaluation. During HUT, continuous beat-to-beat blood pressure (BP), heart rate (HR) and NIRS-derived tissue saturation index (TSI) were measured. BP, HR and TSI at baseline, time of first symptom, presyncope and apparent TLOC were measured. Patients were given feedback and followed for symptom recurrence. Eight predominantly female patients (6/8, 75%) aged 31 years (16-54) were studied with (5/8, 63%) having comorbid psychiatric diagnoses, and (5/8, 63%) presenting with frequent episodes of prolonged TLOC with eyes closed (6/8, 75%). All patients experienced reproduction of typical events during HUT. Systolic BP (mmHg) increased from baseline (129.7 (interquartile range [IQR] 124.9-133.4)) at TLOC (153.0 (IQR 146.7-159.0)) (P-value = 0.012). HR (bpm) increased from baseline 78 (IQR 68.6-90.0) to 115.7 (IQR 93.5-127.9) (P-value = 0.012). TSI (%) remained stable throughout, 71.4 (IQR 67.5-72.9) at baseline vs. 71.0 (IQR 68.2-73.0) at TLOC (P-value = 0.484). NIRS provides a non-invasive surrogate of cerebral perfusion during HUT. We propose HUT incorporating NIRS monitoring in the diagnostic algorithm for patients with suspected PPS.

Sections du résumé

BACKGROUND BACKGROUND
Psychogenic pseudosyncope (PPS), a conversion disorder and syncope mimic, accounts for a large proportion of 'unexplained syncope'. PPS is diagnosed by reproduction of patients' symptoms during head-up tilt (HUT). Electroencephalogram (EEG), a time consuming and resource intensive technology, is used during HUT to demonstrate absence of cerebral hypoperfusion during transient loss of consciousness (TLOC). Near-infrared spectroscopy (NIRS) is a simple, non-invasive technology for continuous monitoring of cerebral perfusion. We present a series of patients for whom PPS diagnosis was supported by NIRS during HUT.
METHODS METHODS
Eight consecutive patients with suspected PPS referred to a syncope unit underwent evaluation. During HUT, continuous beat-to-beat blood pressure (BP), heart rate (HR) and NIRS-derived tissue saturation index (TSI) were measured. BP, HR and TSI at baseline, time of first symptom, presyncope and apparent TLOC were measured. Patients were given feedback and followed for symptom recurrence.
RESULTS RESULTS
Eight predominantly female patients (6/8, 75%) aged 31 years (16-54) were studied with (5/8, 63%) having comorbid psychiatric diagnoses, and (5/8, 63%) presenting with frequent episodes of prolonged TLOC with eyes closed (6/8, 75%). All patients experienced reproduction of typical events during HUT. Systolic BP (mmHg) increased from baseline (129.7 (interquartile range [IQR] 124.9-133.4)) at TLOC (153.0 (IQR 146.7-159.0)) (P-value = 0.012). HR (bpm) increased from baseline 78 (IQR 68.6-90.0) to 115.7 (IQR 93.5-127.9) (P-value = 0.012). TSI (%) remained stable throughout, 71.4 (IQR 67.5-72.9) at baseline vs. 71.0 (IQR 68.2-73.0) at TLOC (P-value = 0.484).
CONCLUSIONS CONCLUSIONS
NIRS provides a non-invasive surrogate of cerebral perfusion during HUT. We propose HUT incorporating NIRS monitoring in the diagnostic algorithm for patients with suspected PPS.

Identifiants

pubmed: 31596496
pii: 5584263
doi: 10.1093/qjmed/hcz257
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

239-244

Informations de copyright

© The Author(s) 2019. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Auteurs

P Claffey (P)

Department of Medical Gerontology, Trinity College Dublin, Dublin, Ireland.
Falls and Syncope Unit, Dublin, Ireland.

L Pérez-Denia (L)

Department of Medical Gerontology, Trinity College Dublin, Dublin, Ireland.
Falls and Syncope Unit, Dublin, Ireland.
Department of Medical Physics and Bioengineering, Mercer's Institute for Successful Ageing, St James's Hospital, Dublin, Ireland.

G Rivasi (G)

Syncope Unit, Geriatric Intensive Care Medicine, University of Florence and Azienda Ospedaliero Universitaria Careggi, Florence, Italy.

C Finucane (C)

Department of Medical Gerontology, Trinity College Dublin, Dublin, Ireland.
Falls and Syncope Unit, Dublin, Ireland.
Department of Medical Physics and Bioengineering, Mercer's Institute for Successful Ageing, St James's Hospital, Dublin, Ireland.

R A Kenny (RA)

Department of Medical Gerontology, Trinity College Dublin, Dublin, Ireland.
Falls and Syncope Unit, Dublin, Ireland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH