A Real-Time Vital-Sign Monitoring in the Physical Domain on a Mixed-Signal Reconfigurable Platform.


Journal

IEEE transactions on biomedical circuits and systems
ISSN: 1940-9990
Titre abrégé: IEEE Trans Biomed Circuits Syst
Pays: United States
ID NLM: 101312520

Informations de publication

Date de publication:
12 2019
Historique:
pubmed: 2 11 2019
medline: 19 5 2020
entrez: 1 11 2019
Statut: ppublish

Résumé

This work presents a mixed-signal physical-compu-tation-electronics for monitoring three vital signs; namely heart rate, blood pressure, and blood oxygen saturation; from electrocardiography, arterial blood pressure, and photoplethysmography signals in real-time. The computational circuits are implemented on a reconfigurable and programmable signal-processing platform, namely field-programmable analog array (FPAA). The design leverages the core enabling technology of FPAA, namely floating-gate CMOS devices, and an on-chip low-power microcontroller to achieve energy-efficiency while not compromising accuracy. The custom physical-computation-electronics operating in CMOS subthreshold region, performs low-level (i.e., physiologically-relevant feature extraction) and high-level (i.e., detecting arrhythmia) signal processing in an energy-efficient manner. The on-chip microcontroller is used (1) in the programming mode for controlling the charge storage at the analog-memory elements to introduce patient-dependency into the system and (2) in the run mode to quantify the vital signs. The system has been validated against digital computation results from MATLAB using datasets collected from three healthy subjects and datasets from the MIT/BIH open source database. Based on all recordings in the MIT/BIH database, ECG R-peak detection sensitivity is 94.2%. The processor detects arrhythmia in three MIT/BIH recordings with an average sensitivity of 96.2%. The cardiac processor achieves an average percentage mean error bounded by 3.75%, 6.27%, and 7.3% for R-R duration, systolic blood pressure, and oxygen saturation level calculations; respectively. The power consumption of the ECG, blood-pressure and photo-plethysmography processing circuitry are 126 nW, 251 nW and 1.44 μW respectively in a 350 nm process. Overall, the cardiac processor consumes 1.82 μW.

Identifiants

pubmed: 31670678
doi: 10.1109/TBCAS.2019.2949778
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1690-1699

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH