Analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience Database for Patient- and Circuit-Related Adverse Events Involving Extracorporeal Membrane Oxygenation.
Databases, Factual
Device Approval
Equipment Failure
Extracorporeal Membrane Oxygenation
/ adverse effects
Heart Diseases
/ diagnosis
Hemodynamics
Humans
Oxygenators, Membrane
/ adverse effects
Patient Safety
Product Surveillance, Postmarketing
Respiratory Insufficiency
/ diagnosis
Risk Assessment
Risk Factors
Treatment Failure
United States
United States Food and Drug Administration
Extracorporeal membrane oxygenation
Food and Drug Administration
Manufacturer and user facility device experience
Veno-arterial
Veno-venous
Journal
Cardiovascular revascularization medicine : including molecular interventions
ISSN: 1878-0938
Titre abrégé: Cardiovasc Revasc Med
Pays: United States
ID NLM: 101238551
Informations de publication
Date de publication:
02 2020
02 2020
Historique:
received:
15
11
2019
accepted:
18
11
2019
pubmed:
27
11
2019
medline:
23
9
2020
entrez:
27
11
2019
Statut:
ppublish
Résumé
We assessed commonly reported patient- and circuit-related adverse events involving extracorporeal membrane oxygenation (ECMO) devices by analyzing post-marketing surveillance data from the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. ECMO is a rescue therapy for critically ill patients requiring oxygenation and cardiopulmonary support. Key configurations include veno-venous (VV) ECMO for respiratory support and veno-arterial (VA) ECMO for cardio-respiratory support. Robust data on the most commonly reported complications associated with ECMO therapy are limited. The MAUDE database was queried from January 1, 2009, through March 31, 2019, yielding 93 reports. After excluding duplicate reports, 82 reports were included in the final analysis. Percentages represent the proportion of total submitted MAUDE reports on ECMO. Of the reported cases, 24 were VV-ECMO, 8 were VA-ECMO, and the remainder were unspecified. The most commonly reported patient-related adverse events included hemodynamic decompensation of patients (12.2%), death (12.2%), atrial perforation (7.3%), and bleeding (7.3%). The most commonly reported failure modes were in the following circuit components: mechanical pump (19.5%, mostly due to technical failure or clots), membrane oxygenator (19.5%, mostly due to tear in the membrane or temperature probe), and access cannulae (18.3%, mostly due to structural damage). Analysis of the MAUDE database demonstrates that in real-world practice, ECMO devices are associated with important complications. With broadened global utilization of ECMO devices, standard complication and failure reporting policies may improve patient selection, operator proficiency, and existing device technology. An analysis of the Food and Drug Administration's Manufacturer and User Facility Device Experience database demonstrates that in real-world practice, extracorporeal membrane oxygenation devices are associated with serious complications. The most commonly reported patient-related adverse events were hemodynamic decompensation of patients and death, and the most commonly reported failure modes were in the device's mechanical pump and membrane oxygenator.
Sections du résumé
BACKGROUND/PURPOSE
We assessed commonly reported patient- and circuit-related adverse events involving extracorporeal membrane oxygenation (ECMO) devices by analyzing post-marketing surveillance data from the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. ECMO is a rescue therapy for critically ill patients requiring oxygenation and cardiopulmonary support. Key configurations include veno-venous (VV) ECMO for respiratory support and veno-arterial (VA) ECMO for cardio-respiratory support. Robust data on the most commonly reported complications associated with ECMO therapy are limited.
METHODS/MATERIALS
The MAUDE database was queried from January 1, 2009, through March 31, 2019, yielding 93 reports. After excluding duplicate reports, 82 reports were included in the final analysis.
RESULTS
Percentages represent the proportion of total submitted MAUDE reports on ECMO. Of the reported cases, 24 were VV-ECMO, 8 were VA-ECMO, and the remainder were unspecified. The most commonly reported patient-related adverse events included hemodynamic decompensation of patients (12.2%), death (12.2%), atrial perforation (7.3%), and bleeding (7.3%). The most commonly reported failure modes were in the following circuit components: mechanical pump (19.5%, mostly due to technical failure or clots), membrane oxygenator (19.5%, mostly due to tear in the membrane or temperature probe), and access cannulae (18.3%, mostly due to structural damage).
CONCLUSIONS
Analysis of the MAUDE database demonstrates that in real-world practice, ECMO devices are associated with important complications. With broadened global utilization of ECMO devices, standard complication and failure reporting policies may improve patient selection, operator proficiency, and existing device technology.
SUMMARY
An analysis of the Food and Drug Administration's Manufacturer and User Facility Device Experience database demonstrates that in real-world practice, extracorporeal membrane oxygenation devices are associated with serious complications. The most commonly reported patient-related adverse events were hemodynamic decompensation of patients and death, and the most commonly reported failure modes were in the device's mechanical pump and membrane oxygenator.
Identifiants
pubmed: 31767523
pii: S1553-8389(19)30757-2
doi: 10.1016/j.carrev.2019.11.011
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
230-234Informations de copyright
Copyright © 2019 Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest Ron Waksman: Advisory Board: Medtronic; Consultant: Medtronic. Toby Rogers: Consultant: Medtronic. All other authors: None.