Positive expiratory pressure physiotherapy for airway clearance in people with cystic fibrosis.
Journal
The Cochrane database of systematic reviews
ISSN: 1469-493X
Titre abrégé: Cochrane Database Syst Rev
Pays: England
ID NLM: 100909747
Informations de publication
Date de publication:
27 11 2019
27 11 2019
Historique:
entrez:
28
11
2019
pubmed:
28
11
2019
medline:
24
4
2020
Statut:
epublish
Résumé
Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis (CF). Positive expiratory pressure (PEP) devices provide back pressure to the airways during expiration. This may improve clearance by building up gas behind mucus via collateral ventilation and by temporarily increasing functional residual capacity. The developers of the PEP technique recommend using PEP with a mask in order to avoid air leaks via the upper airways and mouth. In addition, increasing forced residual capacity (FRC) has not been demonstrated using mouthpiece PEP. Given the widespread use of PEP devices, there is a need to determine the evidence for their effect. This is an update of a previously published review. To determine the effectiveness and acceptability of PEP devices compared to other forms of physiotherapy as a means of improving mucus clearance and other outcomes in people with CF. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising of references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings. The electronic database CINAHL was also searched from 1982 to 2017. Most recent search of the Group's CF Trials Register: 20 February 2019. Randomised controlled studies in which PEP was compared with any other form of physiotherapy in people with CF. This included, postural drainage and percussion (PDPV), active cycle of breathing techniques (ACBT), oscillating PEP devices, thoracic oscillating devices, bilevel positive airway pressure (BiPaP) and exercise. Three authors independently applied the inclusion and exclusion criteria to publications, assessed the risk of bias of the included studies and assessed the quality of the evidence using the GRADE recommendations. A total of 28 studies (involving 788 children and adults) were included in the review; 18 studies involving 296 participants were cross-over in design. Data were not published in sufficient detail in most of these studies to perform any meta-analysis. In 22 of the 28 studies the PEP technique was performed using a mask, in three of the studies a mouthpiece was used with nose clips and in three studies it was unclear whether a mask or mouthpiece was used. These studies compared PEP to ACBT, autogenic drainage (AD), oral oscillating PEP devices, high-frequency chest wall oscillation (HFCWO) and BiPaP and exercise. Forced expiratory volume in one second was the review's primary outcome and the most frequently reported outcome in the studies (24 studies, 716 participants). Single interventions or series of treatments that continued for up to three months demonstrated little or no difference in effect between PEP and other methods of airway clearance on this outcome (low- to moderate-quality evidence). However, long-term studies had equivocal or conflicting results regarding the effect on this outcome (low- to moderate-quality evidence). A second primary outcome was the number of respiratory exacerbations. There was a lower exacerbation rate in participants using PEP compared to other techniques when used with a mask for at least one year (five studies, 232 participants; moderate- to high-quality evidence). In one of the included studies which used PEP with a mouthpiece, it was reported (personal communication) that there was no difference in the number of respiratory exacerbations (66 participants, low-quality evidence). Participant preference was reported in 10 studies; and in all studies with an intervention period of at least one month, this was in favour of PEP. The results for the remaining outcome measures (including our third primary outcome of mucus clearance) were not examined or reported in sufficient detail to provide any high-quality evidence; only very low- to moderate-quality evidence was available for other outcomes. There was limited evidence reported on adverse events; these were measured in five studies, two of which found no events. In a study where infants performing either PEP or PDPV experienced some gastro-oesophageal reflux , this was more severe in the PDPV group (26 infants, low-quality evidence). In PEP versus oscillating PEP, adverse events were only reported in the flutter group (five participants complained of dizziness, which improved after further instructions on device use was provided) (22 participants, low-quality evidence). In PEP versus HFCWO, from one long-term high-quality study (107 participants) there was little or no difference in terms of number of adverse events; however, those in the PEP group had fewer adverse events related to the lower airways when compared to HFCWO (high-certainty evidence). Many studies had a risk of bias as they did not report how the randomisation sequence was either generated or concealed. Most studies reported the number of dropouts and also reported on all planned outcome measures. The evidence provided by this review is of variable quality, but suggests that all techniques and devices described may have a place in the clinical treatment of people with CF. Following meta-analyses of the effects of PEP versus other airway clearance techniques on lung function and patient preference, this Cochrane Review demonstrated that there was high-quality evidence that showed a significant reduction in pulmonary exacerbations when PEP using a mask was compared with HFCWO. It is important to note that airway clearance techniques should be individualised throughout life according to developmental stages, patient preferences, pulmonary symptoms and lung function. This also applies as conditions vary between baseline function and pulmonary exacerbations.
Sections du résumé
BACKGROUND
Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis (CF). Positive expiratory pressure (PEP) devices provide back pressure to the airways during expiration. This may improve clearance by building up gas behind mucus via collateral ventilation and by temporarily increasing functional residual capacity. The developers of the PEP technique recommend using PEP with a mask in order to avoid air leaks via the upper airways and mouth. In addition, increasing forced residual capacity (FRC) has not been demonstrated using mouthpiece PEP. Given the widespread use of PEP devices, there is a need to determine the evidence for their effect. This is an update of a previously published review.
OBJECTIVES
To determine the effectiveness and acceptability of PEP devices compared to other forms of physiotherapy as a means of improving mucus clearance and other outcomes in people with CF.
SEARCH METHODS
We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising of references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings. The electronic database CINAHL was also searched from 1982 to 2017. Most recent search of the Group's CF Trials Register: 20 February 2019.
SELECTION CRITERIA
Randomised controlled studies in which PEP was compared with any other form of physiotherapy in people with CF. This included, postural drainage and percussion (PDPV), active cycle of breathing techniques (ACBT), oscillating PEP devices, thoracic oscillating devices, bilevel positive airway pressure (BiPaP) and exercise.
DATA COLLECTION AND ANALYSIS
Three authors independently applied the inclusion and exclusion criteria to publications, assessed the risk of bias of the included studies and assessed the quality of the evidence using the GRADE recommendations.
MAIN RESULTS
A total of 28 studies (involving 788 children and adults) were included in the review; 18 studies involving 296 participants were cross-over in design. Data were not published in sufficient detail in most of these studies to perform any meta-analysis. In 22 of the 28 studies the PEP technique was performed using a mask, in three of the studies a mouthpiece was used with nose clips and in three studies it was unclear whether a mask or mouthpiece was used. These studies compared PEP to ACBT, autogenic drainage (AD), oral oscillating PEP devices, high-frequency chest wall oscillation (HFCWO) and BiPaP and exercise. Forced expiratory volume in one second was the review's primary outcome and the most frequently reported outcome in the studies (24 studies, 716 participants). Single interventions or series of treatments that continued for up to three months demonstrated little or no difference in effect between PEP and other methods of airway clearance on this outcome (low- to moderate-quality evidence). However, long-term studies had equivocal or conflicting results regarding the effect on this outcome (low- to moderate-quality evidence). A second primary outcome was the number of respiratory exacerbations. There was a lower exacerbation rate in participants using PEP compared to other techniques when used with a mask for at least one year (five studies, 232 participants; moderate- to high-quality evidence). In one of the included studies which used PEP with a mouthpiece, it was reported (personal communication) that there was no difference in the number of respiratory exacerbations (66 participants, low-quality evidence). Participant preference was reported in 10 studies; and in all studies with an intervention period of at least one month, this was in favour of PEP. The results for the remaining outcome measures (including our third primary outcome of mucus clearance) were not examined or reported in sufficient detail to provide any high-quality evidence; only very low- to moderate-quality evidence was available for other outcomes. There was limited evidence reported on adverse events; these were measured in five studies, two of which found no events. In a study where infants performing either PEP or PDPV experienced some gastro-oesophageal reflux , this was more severe in the PDPV group (26 infants, low-quality evidence). In PEP versus oscillating PEP, adverse events were only reported in the flutter group (five participants complained of dizziness, which improved after further instructions on device use was provided) (22 participants, low-quality evidence). In PEP versus HFCWO, from one long-term high-quality study (107 participants) there was little or no difference in terms of number of adverse events; however, those in the PEP group had fewer adverse events related to the lower airways when compared to HFCWO (high-certainty evidence). Many studies had a risk of bias as they did not report how the randomisation sequence was either generated or concealed. Most studies reported the number of dropouts and also reported on all planned outcome measures.
AUTHORS' CONCLUSIONS
The evidence provided by this review is of variable quality, but suggests that all techniques and devices described may have a place in the clinical treatment of people with CF. Following meta-analyses of the effects of PEP versus other airway clearance techniques on lung function and patient preference, this Cochrane Review demonstrated that there was high-quality evidence that showed a significant reduction in pulmonary exacerbations when PEP using a mask was compared with HFCWO. It is important to note that airway clearance techniques should be individualised throughout life according to developmental stages, patient preferences, pulmonary symptoms and lung function. This also applies as conditions vary between baseline function and pulmonary exacerbations.
Identifiants
pubmed: 31774149
doi: 10.1002/14651858.CD003147.pub5
pmc: PMC6953327
doi:
Types de publication
Journal Article
Meta-Analysis
Research Support, Non-U.S. Gov't
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Commentaires et corrections
Type : UpdateOf
Type : CommentIn
Informations de copyright
Copyright © 2019 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
Références
Scand J Respir Dis. 1979 Oct;60(5):260-6
pubmed: 392747
Curr Opin Pulm Med. 1996 Nov;2(6):447-51
pubmed: 9363183
J Clin Med Res. 2011 Dec;3(6):279-84
pubmed: 22393338
Arch Dis Child. 1986 Jun;61(6):598-600
pubmed: 3524474
Dev Period Med. 2015 Jan-Mar;19(1):50-9
pubmed: 26003070
Cochrane Database Syst Rev. 2005 Jan 25;(1):CD002011
pubmed: 15674888
PLoS One. 2014 Sep 15;9(9):e106591
pubmed: 25222606
Arch Bronconeumol. 1999 Jun;35(6):275-9
pubmed: 10410207
Infection. 1987;15(5):381-4
pubmed: 3319913
Aust Paediatr J. 1987 Oct;23(5):283-4
pubmed: 3326574
Arch Dis Child. 2019 Jan;104(1):37-42
pubmed: 29794108
Am J Respir Crit Care Med. 1995 Apr;151(4):939-41
pubmed: 7697269
Respir Physiol Neurobiol. 2018 Aug;254:36-39
pubmed: 29684501
Thorax. 2013 Aug;68(8):746-51
pubmed: 23407019
Cochrane Database Syst Rev. 2006 Apr 19;(2):CD003147
pubmed: 16625571
Del Med J. 1999 Jan;71(1):13-8
pubmed: 10024754
Eur Respir J. 1998 Jul;12(1):143-7
pubmed: 9701429
Pediatr Pulmonol. 1986 Nov-Dec;2(6):358-67
pubmed: 3543830
Ugeskr Laeger. 1982 May 24;144(21):1532-6
pubmed: 6753285
Rev Mal Respir. 2015 May;32(5):493-9
pubmed: 25725980
Bull Eur Physiopathol Respir. 1985 Jul-Aug;21(4):339-43
pubmed: 3899222
J R Soc Med. 2000;93 Suppl 38:27-36
pubmed: 10911816
Thorax. 1986 Dec;41(12):951-4
pubmed: 3296295
Eur J Respir Dis. 1984 Aug;65(6):423-32
pubmed: 6381081
Cochrane Database Syst Rev. 2013 Sep 04;(9):CD001401
pubmed: 24006212
J Pediatr. 1997 Oct;131(4):570-4
pubmed: 9386661
Chest. 1994 Dec;106(6):1872-82
pubmed: 7988215
Pediatr Pulmonol. 1995 Jan;19(1):16-22
pubmed: 7675553
Int J Epidemiol. 2002 Feb;31(1):140-9
pubmed: 11914310
Chest. 1991 Nov;100(5):1350-7
pubmed: 1935294
Am J Epidemiol. 2001 Feb 15;153(4):345-52
pubmed: 11207152
J R Soc Med. 1993;86 Suppl 20:23-9
pubmed: 8501759
Phys Ther. 2005 Dec;85(12):1278-89
pubmed: 16305267
Acta Physiol Hung. 2012 Sep;99(3):324-31
pubmed: 22982720
Respir Med. 2018 Sep;142:23-28
pubmed: 30170797
Eur Respir J. 2006 Jun;27(6):1204-9
pubmed: 16455834
Med Wieku Rozwoj. 2000 Jul-Sep;4(3):247-59
pubmed: 11093342
Pediatr Pulmonol. 1997 Aug;24(2):137-42; discussion 159-61
pubmed: 9292910
J Cyst Fibros. 2010 May;9(3):187-92
pubmed: 20153269
Physiother Theory Pract. 2010 Apr 22;26(3):143-9
pubmed: 20331370
Phys Ther. 2004 Jun;84(6):524-37
pubmed: 15161418
Pediatrics. 2005 Oct;116(4):e549-54
pubmed: 16147970
Acta Paediatr Scand. 1991 Jan;80(1):51-6
pubmed: 2028789
Pediatr Pulmonol. 1990;8(3):188-202
pubmed: 2190148
Lung. 1992;170(6):323-30
pubmed: 1434782
Respir Care. 2012 Nov;57(11):1914-9
pubmed: 22417659
Physiother Res Int. 2017 Jul;22(3):
pubmed: 26929396
Respir Care. 2006 Oct;51(10):1154-61
pubmed: 17005061
Respir Care. 2005 Nov;50(11):1438-44
pubmed: 16253150
Cochrane Database Syst Rev. 2004;(1):CD003147
pubmed: 14974007
Lancet. 2003 Jan 25;361(9354):349-50; aurhor reply 350
pubmed: 12559892
Eur Respir J. 1992 Jun;5(6):748-53
pubmed: 1628733
Cochrane Database Syst Rev. 2015 Jun 17;(6):CD003147
pubmed: 26083308
Respir Care. 2006 Oct;51(10):1145-53
pubmed: 17005060
Pediatr Pulmonol. 2001 Nov;32(5):372-7
pubmed: 11596162
Thorax. 1991 Apr;46(4):252-6
pubmed: 2038733
J Pediatr. 2001 Jun;138(6):845-50
pubmed: 11391327
BMJ. 2003 Sep 6;327(7414):557-60
pubmed: 12958120
Can Respir J. 2003 Mar;10(2):94-8
pubmed: 12687028
BMC Pulm Med. 2018 Jun 14;18(1):99
pubmed: 29898704