Cryoballoon vs. radiofrequency lesions as detected by late-enhancement cardiac magnetic resonance after ablation of paroxysmal atrial fibrillation: a case-control study.
Atrial fibrillation
Cryoballoon ablation
Delayed-enhancement magnetic resonance imaging
Gaps
Radiofrequency ablation
Journal
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649
Informations de publication
Date de publication:
01 03 2020
01 03 2020
Historique:
received:
22
02
2019
accepted:
17
10
2019
pubmed:
11
12
2019
medline:
29
6
2021
entrez:
11
12
2019
Statut:
ppublish
Résumé
Cryoballoon (CB) ablation has emerged as a reliable modality to isolate pulmonary veins (PVs) in atrial fibrillation. Ablation lesions and the long-term effects of energy delivery can be assessed by delayed-enhancement cardiac magnetic resonance (DE-CMR). The aim of the study was to compare the number, extension, and localization of gaps in CB and radiofrequency (RF) techniques in pulmonary vein isolation (PVI). Consecutive patients submitted to PVI with CB in whom DE-CMR images were available (n = 30) were matched (1:1) to patients who underwent PVI with RF (n = 30), considering age, sex, hypertension, and diabetes. Delayed-enhancement cardiac magnetic resonance was obtained at 3 months post-procedure, and images were processed to assess the mean number of gaps around PV ostia, their localization, and the normalized gap length (NGL), calculated as the difference between total gap length and total PV perimeter. Patients were followed up for 12 months. The CB and RF procedures did not differ in the mean number of gaps per patient (4.40 vs. 5.13 gaps, respectively; P = 0.21) nor NGL (0.35 vs. 0.32, P = 0.59). For both techniques, a higher mean number of gaps were detected in right vs. left PVs (3.18 vs. 1.58, respectively; P = 0.01). The incidence of recurrences did not differ between techniques (odds ratio 1.87, 95% confidence interval 0.66-4.97; P = 0.29). Location and extension of ablation gaps in PVI did not differ between CB and RF groups in DE-CMR image analysis.
Identifiants
pubmed: 31821484
pii: 5671763
doi: 10.1093/europace/euz309
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
382-387Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.