CCMod: a GATE module for Compton camera imaging simulation.


Journal

Physics in medicine and biology
ISSN: 1361-6560
Titre abrégé: Phys Med Biol
Pays: England
ID NLM: 0401220

Informations de publication

Date de publication:
28 02 2020
Historique:
pubmed: 24 12 2019
medline: 20 9 2020
entrez: 24 12 2019
Statut: epublish

Résumé

Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13°. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared.

Identifiants

pubmed: 31869822
doi: 10.1088/1361-6560/ab6529
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

055004

Commentaires et corrections

Type : ErratumIn

Auteurs

A Etxebeste (A)

Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, France.

D Dauvergne (D)

LPSC, Université Grenoble-Alpes, CNRS/IN2P3 UMR 5821, Grenoble, France.

M Fontana (M)

Univ. Lyon, Univ. Claude Bernard Lyon 1, CNRS/IN2P3, IP2I Lyon, F-69622 Villeurbanne, France.

J M Létang (JM)

Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, France.

G Llosá (G)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

E Munoz (E)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

J F Oliver (JF)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

É Testa (É)

Univ. Lyon, Univ. Claude Bernard Lyon 1, CNRS/IN2P3, IP2I Lyon, F-69622 Villeurbanne, France.

D Sarrut (D)

Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, France.

Articles similaires

Failed radial head arthroplasty treated by removal of the implant.

Juan Ameztoy Gallego, Blanca Diez Sanchez, Afonso Vaquero-Picado et al.
1.00
Humans Male Female Middle Aged Range of Motion, Articular
Humans Meta-Analysis as Topic Sample Size Models, Statistical Computer Simulation
Humans Algorithms Software Artificial Intelligence Computer Simulation
Humans Shoulder Fractures Tomography, X-Ray Computed Neural Networks, Computer Female

Classifications MeSH