Long-term clinical outcome and performance of transcatheter aortic valve replacement with a self-expandable bioprosthesis.
Aortic stenosis
Durability
Transcatheter aortic valve replacement
Valve deterioration
Journal
European heart journal
ISSN: 1522-9645
Titre abrégé: Eur Heart J
Pays: England
ID NLM: 8006263
Informations de publication
Date de publication:
21 05 2020
21 05 2020
Historique:
received:
03
04
2019
revised:
28
06
2019
accepted:
06
12
2019
pubmed:
7
1
2020
medline:
15
5
2021
entrez:
7
1
2020
Statut:
ppublish
Résumé
In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.
Identifiants
pubmed: 31904800
pii: 5697056
doi: 10.1093/eurheartj/ehz925
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1876-1886Commentaires et corrections
Type : CommentIn
Informations de copyright
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.