Résumé
The purpose of this study was to identify a cut-off value to predict the resolution of incomplete-stent-apposition (ISA) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation at early follow-up. To date, appropriate stent apposition at the acute period using intracoronary imaging has been recommended because persistent ISA is considered to be a risk factor for stent thrombosis. We examined the indices for resolving acute ISA. In particular, we determined the cut-off value for strut vessel distance (SV-distance) as visualized by optical coherence tomography (OCT) at 8 months after CoCr-EES implantation. However, the cut-off value of SV-distance for the earlier resolution of ISA is unclear. A total of 95 cases and 103 stents were registered in the MECHANISM Elective substudy. The SV-distance was measured at the deepest site of the target malapposition and every 1 mm from the proximal edge to the distal edge of the mal-apposed area using OCT. Cut-off values for ISA resolution at 1 and 3 months were estimated by SV-distance using receiver operating characteristic analysis. The total number of analyzed struts was 14,418 at the 1-month follow-up and 11,986 at the 3-month follow-up. The optimal SV-distance cut-off values just after stent implantation to predict ISA resolution were 185 µm at the 1-month follow-up and 195 μm at the 3-month follow-up. For resolution of ISA, SV-distance cut-off values of 185 µm at 1 month postimplantation and 195 μm at 3 months postimplantation can be used as the index of endpoint of the percutaneous coronary intervention.
Sections du résumé
OBJECTIVE
The purpose of this study was to identify a cut-off value to predict the resolution of incomplete-stent-apposition (ISA) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation at early follow-up.
BACKGROUND
To date, appropriate stent apposition at the acute period using intracoronary imaging has been recommended because persistent ISA is considered to be a risk factor for stent thrombosis. We examined the indices for resolving acute ISA. In particular, we determined the cut-off value for strut vessel distance (SV-distance) as visualized by optical coherence tomography (OCT) at 8 months after CoCr-EES implantation. However, the cut-off value of SV-distance for the earlier resolution of ISA is unclear.
METHODS
A total of 95 cases and 103 stents were registered in the MECHANISM Elective substudy. The SV-distance was measured at the deepest site of the target malapposition and every 1 mm from the proximal edge to the distal edge of the mal-apposed area using OCT. Cut-off values for ISA resolution at 1 and 3 months were estimated by SV-distance using receiver operating characteristic analysis.
RESULTS
The total number of analyzed struts was 14,418 at the 1-month follow-up and 11,986 at the 3-month follow-up. The optimal SV-distance cut-off values just after stent implantation to predict ISA resolution were 185 µm at the 1-month follow-up and 195 μm at the 3-month follow-up.
CONCLUSION
For resolution of ISA, SV-distance cut-off values of 185 µm at 1 month postimplantation and 195 μm at 3 months postimplantation can be used as the index of endpoint of the percutaneous coronary intervention.
Identifiants
pubmed: 31924410
pii: S0914-5087(19)30380-6
doi: 10.1016/j.jjcc.2019.12.006
pii:
doi:
Substances chimiques
Chromium Alloys
0
Immunosuppressive Agents
0
Everolimus
9HW64Q8G6G
Types de publication
Clinical Trial
Journal Article
Multicenter Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
641-647Informations de copyright
Copyright © 2019 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.