T2w-MRI signal normalization affects radiomics features reproducibility.

MRI intensity normalization prostate cancer radiomics reproducibility assessment

Journal

Medical physics
ISSN: 2473-4209
Titre abrégé: Med Phys
Pays: United States
ID NLM: 0425746

Informations de publication

Date de publication:
Apr 2020
Historique:
received: 08 08 2019
revised: 13 01 2020
accepted: 14 01 2020
pubmed: 24 1 2020
medline: 27 1 2021
entrez: 24 1 2020
Statut: ppublish

Résumé

Despite its increasing application, radiomics has not yet demonstrated a solid reliability, due to the difficulty in replicating analyses. The extraction of radiomic features from clinical MRI (T1w/T2w) presents even more challenges because of the absence of well-defined units (e.g. HU). Some preprocessing steps are required before the estimation of radiomic features and one of this is the intensity normalization, that can be performed using different methods. The aim of this work was to evaluate the effect of three different normalization techniques, applied on T2w-MRI images of the pelvic region, on radiomic features reproducibility. T2w-MRI acquired before (MRI1) and 12 months after radiotherapy (MRI2) from 14 patients treated for prostate cancer were considered. Four different conditions were analyzed: (a) the original MRI (No_Norm); (b) MRI normalized by the mean image value (Norm_Mean); (c) MRI normalized by the mean value of the urine in the bladder (Norm_ROI); (d) MRI normalized by the histogram-matching method (Norm_HM). Ninety-one radiomic features were extracted from three organs of interest (prostate, internal obturator muscles and bulb) at both time-points and on each image discretized using a fixed bin-width approach and the difference between the two time-points was calculated (Δfeature). To estimate the effect of normalization methods on the reproducibility of radiomic features, ICC was calculated in three analyses: (a) considering the features extracted on MRI2 in the four conditions together and considering the influence of each method separately, with respect to No_Norm; (b) considering the features extracted on MRI2 in the four conditions with respect to the inter-observer variability in region of interest (ROI) contouring, considering also the effect of the discretization approach; (c) considering Δfeature to evaluate if some indices can recover some consistency when differences are calculated. Nearly 60% of the features have shown poor reproducibility (ICC < 0.5) on MRI2 and the method that most affected features reliability was Norm_ROI (average ICC of 0.45). The other two methods were similar, except for first-order features, where Norm_HM outperformed Norm_Mean (average ICC = 0.33 and 0.76 for Norm_Mean and Norm_HM, respectively). In the inter-observer setting, the number of reproducible features varied in the three structures, being higher in the prostate than in the penile bulb and in the obturators. The analysis on Δfeature highlighted that more than 60% of the features were not consistent with respect to the normalization method and confirmed the high reproducibility of the features between Norm_Mean and Norm_HM, whereas Norm_ROI was the less reproducible method. The normalization process impacts the reproducibility of radiomic features, both in terms of changes in the image information content and in the inter-observer setting. Among the considered methods, Norm_Mean and Norm_HM seem to provide the most reproducible features with respect to the original image and also between themselves, whereas Norm_ROI generates less reproducible features. Only a very small subset of feature remained reproducible and independent in any tested condition, regardless the ROI and the adopted algorithm: skewness or kurtosis, correlation and one among Imc2, Idmn and Idn from GLCM group.

Identifiants

pubmed: 31971614
doi: 10.1002/mp.14038
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1680-1691

Subventions

Organisme : Italo Monzino Foundation
Organisme : Italian Ministry of Health (MoH) and MIUR

Informations de copyright

© 2020 American Association of Physicists in Medicine.

Références

Aerts HJWL, Velazquez ER, Leijenaar RTH, et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nat Commun. 2014;5:4006.
Al-Kadi OS, Watson D. Texture analysis of aggressive and nonaggressive lung tumor CE CT images. IEEE Trans Biomed Eng. 2008;55:1822-1830.
Wibmer A, Hricak H, Gondo T, et al. Haralick texture analysis of prostate MRI: utility for differentiating non-cancerous prostate from prostate cancer and differentiating prostate cancers with different Gleason scores. Eur Radiol. 2015;25:2840-2850.
Tixier F, Le Rest CC, Hatt M, et al. Intratumor heterogeneity characterized by textural features on baseline 18F-FDG PET images predicts response to concomitant radiochemotherapy in esophageal cancer. J Nucl Med. 2011;52:369-378.
Scalco E, Fiorino C, Cattaneo GM, Sanguineti G, Rizzo G. Texture analysis for the assessment of structural changes in parotid glands induced by radiotherapy. Radiother Oncol. 2013;109:384-387.
Scalco E, Rizzo G. Texture analysis of medical images for radiotherapy applications. Br J Radiol. 2017;90:20160642.
Schwier M, van Griethuysen J, Vangel MG, et al. Repeatability of multiparametric prostate MRI radiomics features. Sci Rep. 2019;9:9441.
Traverso A, Wee L, Dekker A, Gillies R. Repeatability and reproducibility of radiomic features: a systematic review. Int J Radiat Oncol. 2018;102:1143-1158.
Yan J, Chu-Shern JL, Loi HY, et al. Impact of image reconstruction settings on texture features in 18F-FDG PET. J Nucl Med. 2015;56:1667-73.
van Velden FHP, Kramer GM, Frings V, et al. Repeatability of Radiomic Features in Non-Small-Cell Lung Cancer [(18)F]FDG-PET/CT Studies: Impact of Reconstruction and Delineation. Mol Imaging Biol. 2016;18:788-795.
Hatt M, Majdoub M, Vallières M, et al. 18F-FDG PET Uptake Characterization Through Texture Analysis: Investigating the Complementary Nature of Heterogeneity and Functional Tumor Volume in a Multi-Cancer Site Patient Cohort. J Nucl Med. 2015;56:38-44.
Parmar C, Velazquez ER, Leijenaar R, et al. Robust radiomics feature quantification using semiautomatic volumetric segmentation. PLoS ONE. 2014;9:1-8.
Hatt M, Tixier F, Pierce L, Kinahan PE, Le Rest CC, Visvikis D. Characterization of PET/CT images using texture analysis: the past, the present… any future? Eur J Nucl Med Mol Imaging. 2017;44:151-165.
Zwanenburg A, Leger S, Vallières M, Löck S.and for the I.B.S. Initiative, “Image biomarker standardisation initiative”, (July), (2016).
Lemaitre G, Martì R, Freixenet J, Vilanova JC, Walker PM, Meriaudeau F. Computer-Aided Detection and diagnosis for prostate cancer based on mono and multi-parametric MRI: a review. Comput Biol Med. 2015;60:8-31.
Collewet G, Strzelecki M, Mariette F. Influence of MRI acquisition protocols and image intensity normalization methods on texture classification. Magn Reson Imaging. 2004;22:81-91.
Niaf E, Rouvière O, Mège-Lechevallier F, Bratan F, Lartizien C. Computer-aided diagnosis of prostate cancer in the peripheral zone using multiparametric MRI. Phys Med Biol. 2012;57:3833-3851.
Xiao D-D, Yan P-F, Wang Y-X, Osman MS, Zhao H-Y. Glioblastoma and primary central nervous system lymphoma: preoperative differentiation by using MRI-based 3D texture analysis. Clin Neurol Neurosurg. 2018;173:84-90.
Scalco E, Marzi S, Sanguineti G, Farneti A, Rizzo G, Vidiri A. Evaluation of CT-based features and ADC values to assess tumor control on cervical lymph nodes treated with chemo-radiotherapy. Phys Medica. 2016;32:61.
Chirra P, Leo P, Yim M, et al. Multisite evaluation of radiomic feature reproducibility and discriminability for identifying peripheral zone prostate tumors on MRI. J Med Imaging. 2019;6:024502.
Ginsburg SB, Algohary A, Pahwa S, et al. Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: preliminary findings from a multi-institutional study. J Magn Reson Imaging. 2017;46:184-193.
Gnep K, Fargeas A, Gutiérrez-Carvajal RE, et al. Haralick textural features on T2 -weighted MRI are associated with biochemical recurrence following radiotherapy for peripheral zone prostate cancer. J Magn Reson Imaging. 2017;45:103-117.
Scalco E, Rancati T, Pirovano I, et al. Texture analysis of T1-w and T2-w MR images allows a quantitative evaluation of radiation-induced changes of internal obturator muscles after radiotherapy for prostate cancer. Med Phys. 2018;45:1518-1528.
Chirra P, Bloch NB, Rastinehead A, et al. Empirical evaluation of cross-site reproducibility in radiomic features for characterizing prostate MRI. Med Imaging 2018 Comput Diagnosis. 2018;10575:10.
Fiset S, Welch ML, Weiss J, et al. Repeatability and reproducibility of MRI-based radiomic features in cervical cancer. Radiother Oncol. 2019;135:107-114.
Duron L, Balvay D, Vande Perre S, et al. Gray-level discretization impacts reproducible MRI radiomics texture features. PLoS ONE. 2019;14:e0213459.
Fedorov A, Beichel R, Kalpathy-Cramer J, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012;30:1323-1341.
Broggi S, Scalco E, Belli ML, et al. A comparative evaluation of 3 different free-form deformable image registration and contour propagation methods for head and neck MRI. Technol Cancer Res Treat. 2017;16:373-381.
Tustison NJ, Avants BB, Cook PA, et al. N4ITK: improved N3 bias correction. IEEE Trans Med Imaging. 2010;29:1310-1320.
van Griethuysen JJM, Fedorov A, Parmar C, et al. Computational radiomics system to decode the radiographic phenotype. Cancer Res. 2017;77:e104-e107.
Nyul LG, Udupa JK, Zhang X. New variants of a method of MRI scale standardization. IEEE Trans Med Imaging. 2000;19:143-150.
Dice L. Measures of the amount of ecologic association between species. Ecology. 1945;26:297-302.
McGraw K, Wong S. Forming inferences about some intraclass correlation coefficients. American Psychological Association; 1996.
Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155-163.
Welch ML, McIntosh C, Haibe-Kains B, et al. Vulnerabilities of radiomic signature development: the need for safeguards. Radiother. Oncol. 2019;130:2-9.
Hou Z, Li S, Ren W, Liu J, Yan J, Wan S. Radiomic analysis in T2W and SPAIR T2W MRI: predict treatment response to chemoradiotherapy in esophageal squamous cell carcinoma. J Thorac Dis. 2018;10:2256-2267.
Nketiah G, Elschot M, Kim E, et al. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results. Eur Radiol. 2017;27:3050-3059.
Wang HYC, Donovan EM, Nisbet A, et al. The stability of imaging biomarkers in radiomics: a framework for evaluation. Phys Med Biol. 2019;64:165012.
Balagurunathan Y, Gu Y, Wang H, et al. Reproducibility and prognosis of quantitative features extracted from CT images. Transl Oncol. 2014;7:72-87.
Buch K, Kuno H, Qureshi MM, Li B, Sakai O. Quantitative variations in texture analysis features dependent on MRI scanning parameters: a phantom model. J Appl Clin Med Phys (June). 2018;16:253-264.

Auteurs

Elisa Scalco (E)

CNR, Institute of Biomedical Technologies (ITB), Segrate, Italy.
CNR, Institute of Molecular Bioimaging and Physiology (IBFM), Segrate, Italy.

Antonella Belfatto (A)

CNR, Institute of Molecular Bioimaging and Physiology (IBFM), Segrate, Italy.

Alfonso Mastropietro (A)

CNR, Institute of Biomedical Technologies (ITB), Segrate, Italy.
CNR, Institute of Molecular Bioimaging and Physiology (IBFM), Segrate, Italy.

Tiziana Rancati (T)

Fondazione IRCCS Istituto Nazionale dei Tumori, Prostate Cancer Program, Milano, Italy.

Barbara Avuzzi (B)

Radiation Oncology 1, Fondazione IRCCS Istituto Nazionale dei Tumori, Milano, Italy.

Antonella Messina (A)

Radiology, Fondazione IRCCS Istituto Nazionale dei Tumori, Milano, Italy.

Riccardo Valdagni (R)

Fondazione IRCCS Istituto Nazionale dei Tumori, Prostate Cancer Program, Milano, Italy.
Radiation Oncology 1, Fondazione IRCCS Istituto Nazionale dei Tumori, Milano, Italy.
Department of Oncology and Hemato-oncology, Università degli Studi di Milano, Milano, Italy.

Giovanna Rizzo (G)

CNR, Institute of Biomedical Technologies (ITB), Segrate, Italy.
CNR, Institute of Molecular Bioimaging and Physiology (IBFM), Segrate, Italy.

Articles similaires

Humans Ketamine Propofol Pulmonary Atelectasis Female
Humans Magnetic Resonance Imaging Phantoms, Imaging Infant, Newborn Signal-To-Noise Ratio
1.00
Humans Magnetic Resonance Imaging Brain Infant, Newborn Infant, Premature
Cephalometry Humans Anatomic Landmarks Software Internet

Classifications MeSH