Evaluation of placental alpha microglobulin-1(PAMG1) accuracy for prediction of preterm delivery in women with the symptoms of spontaneous preterm labor; a comparison with cervical length and number of contractions.
Placental alpha microglobulin-1
cervical length
prematurity
preterm birth
preterm labor (PAMG-1)
Journal
The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
ISSN: 1476-4954
Titre abrégé: J Matern Fetal Neonatal Med
Pays: England
ID NLM: 101136916
Informations de publication
Date de publication:
Feb 2022
Feb 2022
Historique:
pubmed:
19
2
2020
medline:
27
1
2022
entrez:
19
2
2020
Statut:
ppublish
Résumé
Since the capacity of tertiary centers is limited, identifying women with the risk of preterm delivery is crucial amongst women who refer to hospitals with threatened preterm labor. The purpose of the present study was to evaluate the accuracy of the placental alpha microglobulin-1 (PAMG-1) test for identifying women who referred to hospitals with signs of spontaneous preterm labor and ultimately delivered within ≤48 h and ≤7 of testing and ≤37 weeks of gestation and its comparison with cervical length of <25 mm and number of contractions. A prospective observational study was performed on women with the signs of spontaneous preterm labor. Placental alpha microglobulin-1 (PAMG-1) was evaluated in vaginal secretion. Cervical length (CL) and number of contractions were evaluated and recorded. The test to- spontaneous- delivery interval was documented. Sensitivity (SN), specificity (SP), accuracy rate of the PAMG-1, cervical length of <25 mm and number of contractions in prediction of spontaneous preterm delivery within ≤48 h, ≤7 days and preterm delivery (≤37 weeks of gestation) were calculated. One hundred eighty women finished the study. 44 women had positive PAMG-1 test and 58 women had cervical length of <25 mm. Women with a positive PAMG-1 were more likely to deliver within ≤48 h ( PAMG-1 test showed a higher accuracy rate for prediction of delivery within ≤48 and ≤7 days in comparison with cervical length of <25 mm and number of contractions. Also, PAMG-1 test had a higher positive likelihood ratio for deliveries at ≤37 weeks. PPV for deliveries within ≤48 h and ≤7 days for PAMG-1 was greater than cervical length of <25 mm and number of contractions, however, NPV did not show a significant difference.
Identifiants
pubmed: 32068450
doi: 10.1080/14767058.2020.1728246
doi:
Substances chimiques
Insulin-Like Growth Factor Binding Protein 1
0
Types de publication
Journal Article
Observational Study
Langues
eng
Sous-ensembles de citation
IM