Comparative assessment of von Willebrand factor multimers vs activity for von Willebrand disease using modern contemporary methodologies.

VWF activity VWF multimers von Willebrand disease von Willebrand factor

Journal

Haemophilia : the official journal of the World Federation of Hemophilia
ISSN: 1365-2516
Titre abrégé: Haemophilia
Pays: England
ID NLM: 9442916

Informations de publication

Date de publication:
May 2020
Historique:
received: 06 01 2020
revised: 02 02 2020
accepted: 24 02 2020
pubmed: 12 3 2020
medline: 15 12 2020
entrez: 12 3 2020
Statut: ppublish

Résumé

Diagnosis of von Willebrand disease (VWD) is challenging due to heterogeneity of VWD and test limitations. Many von Willebrand factor (VWF) assays are utilized, including antigen (Ag), activity and multimer analysis. Activity assays include ristocetin cofactor using platelets (VWF:RCo) or other particles incorporating recombinant glycoprotein I ('VWF:GPIbR'), or other GPI binding assays using gain-of-function mutations ('VWF:GPIbM'), or collagen binding (VWF:CB). To comparatively evaluate modern contemporary VWF activity assays vs VWF multimer analysis using modern contemporary methods. Several VWF activity assays (VWF:RCo, VWF:GPIbR, VWF:GPIbM, VWF:CB) assessed (typically as a ratio against VWF:Ag) against a new semi-automated procedure for different types of VWD (1, 3, 2A, 2B, 2M), plus control material (n = 580). The evaluation also focussed on relative loss of high and very high molecular weight multimers (HMWM and VHMWM) by densitometric scanning. All evaluated VWF activity/Ag ratios showed high correlation to the presence/absence of HMWM and VHMWM, although VWF:CB/Ag and VWF:GPIbR/Ag ratios using an automated chemiluminescence method yielded highest correlation coefficients (r = .909 and .874, respectively, for HMWM). Use of the investigative procedure (VHMWM) identified fewer false positives for 'loss' in type 1 VWD. This comparative investigation identified that new automated chemiluminescence VWF activity assays best identified relative loss or presence of HMWM and VHMWM according to activity to Ag ratios and an alternative investigative method for identifying VHMWM in multimer testing for a new commercial multimer method may lead to fewer false identifications of HMW loss in type 1 VWD.

Identifiants

pubmed: 32159272
doi: 10.1111/hae.13957
doi:

Substances chimiques

von Willebrand Factor 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

503-512

Informations de copyright

© 2020 John Wiley & Sons Ltd.

Références

Bowman M, Hopman WM, Rapson D, Lillicrap D, James P. The prevalence of symptomatic von Willebrand disease in primary care practice. J Thromb Haemost. 2010;8(1):213-216.
Sadler JE, Budde U, Eikenboom JCJ, et al. Update on the pathophysiology and classification of von Willebrand disease: a report of the Subcommittee on von Willebrand Factor. J Thromb Haemost. 2006;4(10):2103-2114.
Laffan MA, Lester W, O'Donnell JS, et al. The diagnosis and management of von Willebrand disease: a United Kingdom Haemophilia Centre Doctors Organization guideline approved by the British Committee for Standards in Haematology. Br J Haematol. 2014;167(4):453-465.
Favaloro EJ, Pasalic L, Curnow J. Laboratory tests used to help diagnose von Willebrand disease: an update. Pathology. 2016;48(4):303-318.
Favaloro EJ, Mohammed S, Patzke J. Laboratory testing for von Willebrand factor antigen (VWF:Ag). Methods Mol Biol. 2017;1646:403-416.
Favaloro EJ, Mohammed S. Evaluation of a von Willebrand factor three test panel and chemiluminescent-based assay system for identification of, and therapy monitoring in, von Willebrand disease. Thromb Res. 2016;141:202-211.
Bodo I, Eikenboom J, Montgomery R, et al. Platelet-dependent von Willebrand factor activity. Nomenclature and methodology: communication from the SSC of the ISTH. J Thromb Haemost. 2015;13:1345-1350.
Just S. Laboratory testing for von Willebrand disease: the past, present, and future state of play for von Willebrand factor assays that measure platelet binding activity, with or without ristocetin. Semin Thromb Hemost. 2017;43(1):75-91.
Mohammed S, Favaloro EJ. Laboratory testing for von Willebrand factor ristocetin cofactor (VWF:RCo). Methods Mol Biol. 2017;1646:435-451.
Patzke J, Favaloro EJ. Laboratory testing for von Willebrand factor activity by glycoprotein Ib binding assays (VWF:GPIb). Methods Mol Biol. 2017;1646:453-460.
Favaloro EJ, Mohammed S. Towards improved diagnosis of von Willebrand disease: comparative evaluations of several automated von Willebrand factor antigen and activity assays. Thromb Res. 2014;134:1292-1300.
Favaloro EJ, Mohammed S. Laboratory testing for von Willebrand factor collagen binding (VWF:CB). Methods Mol Biol. 2017;1646:417-433.
Chandler W, Peerschke E, Castellone D, Meijer P. von Willebrand factor assay proficiency testing: the North American specialized coagulation laboratory association experience. Am J Clin Pathol. 2011;135(6):862-869.
Meijer P, Haverkate F. An external quality assessment program for von Willebrand factor laboratory analysis: an overview from the European Concerted Action on Thrombosis and Disabilities Foundation. Semin Thromb Hemost. 2006;32(05):485-491.
Favaloro EJ. Utility of the platelet function analyser (PFA-100/200) for exclusion or detection of von Willebrand disease: a study 22 years in the making. Thromb Res. 2020;88:17-24.
Frontroth JP, Favaloro EJ. Ristocetin-induced platelet aggregation (RIPA) and RIPA mixing studies. Methods Mol Biol. 2017;1646:473-494.
Favaloro EJ, Oliver S. Evaluation of a new commercial von Willebrand factor multimer assay. Haemophilia. 2017;23(4):e373.
Oliver S, Lau KKE, Chapman K, Favaloro EJ. Laboratory testing for von Willebrand factor multimers. Methods Mol Biol. 2017;1646:495-511.
Oliver S, Vanniasinkam T, Mohammed S, Vong R, Favaloro EJ. Semi-automated von Willebrand factor multimer assay for von Willebrand disease: further validation, benefits and limitations. Int J Lab Hematol. 2019;41(6):762-771.
Pikta M, Zemtsovskaja G, Bautista H, et al. Preclinical evaluation of a semi-automated and rapid commercial electrophoresis assay for von Willebrand factor multimers. J Clin Lab Anal. 2018;32(6):e22416.
Bowyer AE, Goodfellow KJ, Seidel H, et al. Evaluation of a semi-automated von Willebrand factor multimer assay, the Hydragel 5 von Willebrand multimer, by two European Centers. Res Practice Thromb Haemost. 2018;2(4):790-799.
Crist RA, Heikal NM, Rodgers GM, Grenache DG, Smock KJ. Evaluation of a new commercial method for von Willebrand factor multimeric analysis. Int J Lab Hematol. 2018;40(5):586-591.
Casonato A, Daidone V, Galletta E, Bertomoro A. Type 2B von Willebrand disease with or without large multimers: a distinction of the two sides of the disorder is long overdue. PLoS ONE. 2017;12(6):e0179566.
Castaman G, Federici AB. Type 2B von Willebrand disease: a matter of plasma plus platelet abnormality. Semin Thromb Hemost. 2016;42(5):478-482.
Favaloro EJ, Pasalic L, Curnow J. Type 2M and Type 2A von Willebrand disease: similar but different. Semin Thromb Hemost. 2016;42(5):483-497.
Favaloro EJ, Bonar RA, Mohammed S, et al. Type 2M von Willebrand disease - more often misidentified than correctly identified. Haemophilia. 2016;22(3):e145-e155.
Favaloro EJ. Detailed von Willebrand factor multimer analysis in patients with von Willebrand disease in the European study, molecular and clinical markers for the diagnosis and management of type 1 von Willebrand disease (MCMDM-1VWD) - a rebuttal. J Thromb Haemost. 2008;6:1999-2001.
Favaloro EJ, Soltani S, McDonald J. Potential laboratory misdiagnosis of haemophilia and von Willebrand Disorder due to cold activation of blood samples for testing. Am J Clin Pathol. 2004;122:686-692.
Favaloro EJ, Oliver S, Mohammed S, et al. Potential misdiagnosis of von Willebrand disease and haemophilia caused by ineffective mixing of thawed plasma. Haemophilia. 2017;23(5):e436-e443.
Ledford-Kraemer MR. Analysis of von Willebrand factor structure by multimer analysis. Am J Hematol. 2010;85:510-514.
Pruthi RK, Daniels TM, Heit JA, Chen D, Owen WG, Nichols WL. Plasma von Willebrand factor multimer quantitative analysis by in-gel immunostaining and infrared fluorescent imaging. Thromb Res. 2010;126:543-549.
Budde U, Schneppenheim R, Eikenboom J, et al. Detailed von Willebrand factor multimer analysis in patients with von Willebrand disease in the European study, molecular and clinical markers for the diagnosis and management of type 1 von Willebrand disease (MCMDM-1VWD). J Thromb Haemost. 2008;6:762-771.

Auteurs

Emmanuel J Favaloro (EJ)

Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia.
Sydney Centres for Thrombosis and Haemostasis, Westmead Hospital, Westmead, NSW, Australia.

Susan Oliver (S)

Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia.

Soma Mohammed (S)

Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia.

Ronny Vong (R)

Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH