Artificial Intelligence Algorithm Detecting Lung Infection in Supine Chest Radiographs of Critically Ill Patients With a Diagnostic Accuracy Similar to Board-Certified Radiologists.


Journal

Critical care medicine
ISSN: 1530-0293
Titre abrégé: Crit Care Med
Pays: United States
ID NLM: 0355501

Informations de publication

Date de publication:
07 2020
Historique:
pubmed: 21 5 2020
medline: 19 5 2021
entrez: 21 5 2020
Statut: ppublish

Résumé

Interpretation of lung opacities in ICU supine chest radiographs remains challenging. We evaluated a prototype artificial intelligence algorithm to classify basal lung opacities according to underlying pathologies. Retrospective study. The deep neural network was trained on two publicly available datasets including 297,541 images of 86,876 patients. One hundred sixty-six patients received both supine chest radiograph and CT scans (reference standard) within 90 minutes without any intervention in between. Algorithm accuracy was referenced to board-certified radiologists who evaluated supine chest radiographs according to side-separate reading scores for pneumonia and effusion (0 = absent, 1 = possible, and 2 = highly suspected). Radiologists were blinded to the supine chest radiograph findings during CT interpretation. Performances of radiologists and the artificial intelligence algorithm were quantified by receiver-operating characteristic curve analysis. Diagnostic metrics (sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) were calculated based on different receiver-operating characteristic operating points. Regarding pneumonia detection, radiologists achieved a maximum diagnostic accuracy of up to 0.87 (95% CI, 0.78-0.93) when considering only the supine chest radiograph reading score 2 as positive for pneumonia. Radiologist's maximum sensitivity up to 0.87 (95% CI, 0.76-0.94) was achieved by additionally rating the supine chest radiograph reading score 1 as positive for pneumonia and taking previous examinations into account. Radiologic assessment essentially achieved nonsignificantly higher results compared with the artificial intelligence algorithm: artificial intelligence-area under the receiver-operating characteristic curve of 0.737 (0.659-0.815) versus radiologist's area under the receiver-operating characteristic curve of 0.779 (0.723-0.836), diagnostic metrics of receiver-operating characteristic operating points did not significantly differ. Regarding the detection of pleural effusions, there was no significant performance difference between radiologist's and artificial intelligence algorithm: artificial intelligence-area under the receiver-operating characteristic curve of 0.740 (0.662-0.817) versus radiologist's area under the receiver-operating characteristic curve of 0.698 (0.646-0.749) with similar diagnostic metrics for receiver-operating characteristic operating points. Considering the minor level of performance differences between the algorithm and radiologists, we regard artificial intelligence as a promising clinical decision support tool for supine chest radiograph examinations in the clinical routine with high potential to reduce the number of missed findings in an artificial intelligence-assisted reading setting.

Identifiants

pubmed: 32433121
doi: 10.1097/CCM.0000000000004397
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e574-e583

Auteurs

Johannes Rueckel (J)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Wolfgang G Kunz (WG)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Boj F Hoppe (BF)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Maximilian Patzig (M)

Institute of Diagnostic and Interventional Neuroradiology, University Hospital, LMU Munich, Munich, Germany.

Mike Notohamiprodjo (M)

Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany.
DIE RADIOLOGIE, Munich, Germany.

Felix G Meinel (FG)

Department of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Rostock, Germany.

Clemens C Cyran (CC)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.
DIE RADIOLOGIE, Munich, Germany.

Michael Ingrisch (M)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Jens Ricke (J)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Bastian O Sabel (BO)

Department of Radiology, University Hospital, LMU Munich, Munich, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH