Résumé
We aim to evaluate the use of silver (PorAg In total, 68 patients were retrospectively evaluated. Median age was 30 years (range 14-83). In total, 29 patients were re-implanted with PorAg At 3-year follow-up, estimated reinfection rate in the silver group was slightly lower than in uncoated EPR (10.3% vs. 17.5%, p = 0.104). Among reinfected patients, only one out of three patients (33%) in the silver group required an amputation compared to 80% in the nonsilver group (p = 0.047). Our results show the efficacy of PorAg