Examination of a dose evaluation method for floor-mounted kV X-ray image-guided radiation therapy systems.


Journal

Radiological physics and technology
ISSN: 1865-0341
Titre abrégé: Radiol Phys Technol
Pays: Japan
ID NLM: 101467995

Informations de publication

Date de publication:
Sep 2020
Historique:
received: 08 10 2019
accepted: 09 04 2020
revised: 07 04 2020
pubmed: 10 6 2020
medline: 29 6 2021
entrez: 10 6 2020
Statut: ppublish

Résumé

Floor-mounted kV X-ray image-guided radiation therapy systems (such as ExacTrac) are used to treat tumors in movable body regions such as the head and neck. ExacTrac requires exposure dose control based on image acquisition. However, placement of the aluminum plate perpendicular to the dosimeter is difficult due to the oblique X-ray beam path. This study provides an evaluation of the entrance surface, organ, and effective doses delivered to the head and neck during image-guided radiation therapy. A semiconductor detector (Unfors Xi) and radiophotoluminescent glass dosimeter (RPLD) were used as dosimeters with entrance surface dose calculation (Sdec) and exposure estimation (PCXMC) software. When the Unfors Xi was placed in front of the flat panel detector (FPD), an accurate entrance surface dose was obtained by considering the X-ray attenuation due to the influence of the distance from X-ray tube to FPD.The couch absorption was 32% and incident air kerma at the patient entrance point was 0.094 mGy for Unfors Xi. The entrance surface doses were 0.12 and 0.122 mGy for the Sdec and RPLD, respectively. The thyroid organ doses were 0.044 and 0.058 mGy for the RPLD and PCXMC, respectively. The effective doses of PCXMC for ExacTrac and cone-beam computed tomography were 0.0068 and 0.31 mSv, respectively. The exposure dose of ExacTrac was approximately 2% of that of cone-beam computed tomography. The results demonstrated that the proposed software-based method is effective for the assessment and management of ExacTrac exposure.

Identifiants

pubmed: 32514938
doi: 10.1007/s12194-020-00570-7
pii: 10.1007/s12194-020-00570-7
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

288-295

Auteurs

Keisuke Hamada (K)

Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1 Notame Minami-ku, Fukuoka-City, Fukuoka, 811-1395, Japan. hamada.keisuke.we@mail.hosp.go.jp.

Toshioh Fujibuchi (T)

Department of Health Sciences, Faculty of Medical Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 811-8582, Japan.

Naoki Yoshida (N)

Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1 Notame Minami-ku, Fukuoka-City, Fukuoka, 811-1395, Japan.

Hiroki Ohura (H)

Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1 Notame Minami-ku, Fukuoka-City, Fukuoka, 811-1395, Japan.

Articles similaires

Selecting optimal software code descriptors-The case of Java.

Yegor Bugayenko, Zamira Kholmatova, Artem Kruglov et al.
1.00
Software Algorithms Programming Languages

Exploring blood-brain barrier passage using atomic weighted vector and machine learning.

Yoan Martínez-López, Paulina Phoobane, Yanaima Jauriga et al.
1.00
Blood-Brain Barrier Machine Learning Humans Support Vector Machine Software
Semiconductors Photosynthesis Polymers Carbon Dioxide Bacteria
Cephalometry Humans Anatomic Landmarks Software Internet

Classifications MeSH