Assessment of left ventricular diastolic function by three-dimensional transthoracic echocardiography.

diastolic dysfunction diastolic function left atrial volume left ventricular filling pressures myocardial strain three-dimensional transthoracic echocardiography

Journal

Echocardiography (Mount Kisco, N.Y.)
ISSN: 1540-8175
Titre abrégé: Echocardiography
Pays: United States
ID NLM: 8511187

Informations de publication

Date de publication:
11 2020
Historique:
received: 20 05 2020
revised: 07 06 2020
accepted: 08 06 2020
pubmed: 1 7 2020
medline: 24 6 2021
entrez: 30 6 2020
Statut: ppublish

Résumé

Doppler echocardiography assessment of left ventricular (LV) filling pressures at rest and during exercise is the most widely used imaging technique to assess LV diastolic function in clinical practice. However, a sizable number of patients evaluated for suspected LV diastolic function show an inconsistency between the various parameters included in the flowchart recommended by current Doppler echocardiography guidelines and results in an undetermined LV diastolic function. Current three-dimensional echocardiography technology allows obtaining accurate measurements of the left atrial volumes and functions that have been shown to improve the diagnostic accuracy and prognostic value of the algorithms recommended for assessing both LV diastolic dysfunction and heart failure with preserved ejection fraction. Moreover, current software packages used to quantify LV size and function provide also volume-time curves showing the dynamic LV volume change throughout the cardiac cycle. Examining the diastolic part of these curves allows the measurement of several indices of LV filling that have been reported to be useful to differentiate patients with normal LV diastolic function from patients with different degrees of diastolic dysfunction. Finally, several software packages allow to obtain also myocardial deformation parameters from the three-dimensional datasets of both the left atrium and the LV providing additional functional parameters that may be useful to improve the diagnostic yield of three-dimensional echocardiography for the LV diastolic dysfunction. This review summarizes the current applications of three-dimensional echocardiography to assess LV diastolic function.

Identifiants

pubmed: 32596833
doi: 10.1111/echo.14782
doi:

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

1951-1956

Informations de copyright

© 2020 Wiley Periodicals LLC.

Références

Pieske B, Tschope C, de Boer RA, et al. How to diagnose heart failure with preserved ejection fraction: the HFA-PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC). Eur Heart J. 2019;40:3297-3317.
Flachskampf FA, Biering-Sorensen T, Solomon SD, Duvernoy O, Bjerner T, Smiseth OA. Cardiac imaging to evaluate left ventricular diastolic function. JACC Cardiovasc Imaging. 2015;8:1071-1093.
Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2016;17:1321-1360.
Singh A, Addetia K, Maffessanti F, Mor-Avi V, Lang RM. LA strain for categorization of LV Diastolic dysfunction. JACC Cardiovasc Imaging. 2017;10:735-743.
Morris DA, Belyavskiy E, Aravind-Kumar R, et al. Potential usefulness and clinical relevance of adding left atrial strain to left atrial volume index in the detection of left ventricular diastolic dysfunction. JACC Cardiovasc Imaging. 2018;11:1405-1415.
Thomas L, Marwick TH, Popescu BA, Donal E, Badano LP. Left atrial structure and function, and left ventricular diastolic dysfunction: JACC state-of-the-art review. J Am Coll Cardiol. 2019;73:1961-1977.
Badano LP, Miglioranza MH, Left MS, et al. Atrial volumes and function by three-dimensional echocardiography: reference values, accuracy, reproducibility, and comparison with two-dimensional echocardiographic measurements. Circulation Cardiovasc Imaging. 2016;9(7):e004229.
Guta AC, Badano LP, Ochoa-Jimenez RC, et al. Three-dimensional echocardiography to assess left ventricular geometry and function. Expert Rev Cardiovasc Ther. 2019;17:801-815.
Jenkins C, Bricknell K, Marwick TH. Use of real-time three-dimensional echocardiography to measure left atrial volume: comparison with other echocardiographic techniques. J Am Soc Echocardiogr. 2005;18:991-997.
Muller H, Reverdin S, Burri H, Shah D, Lerch R. Measurement of left and right atrial volume in patients undergoing ablation for atrial arrhythmias: comparison of a manual versus semiautomatic algorithm of real time 3D echocardiography. Echocardiography. 2014;31:499-507.
Wu VC, Takeuchi M, Kuwaki H, et al. Prognostic value of LA volumes assessed by transthoracic 3D echocardiography: comparison with 2D echocardiography. JACC Cardiovasc Imaging. 2013;6:1025-1035.
Mor-Avi V, Yodwut C, Jenkins C, et al. Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR. JACC Cardiovasc Imaging. 2012;5:769-777.
Iwataki M, Takeuchi M, Otani K, et al. Measurement of left atrial volume from transthoracic three-dimensional echocardiographic datasets using the biplane Simpson's technique. J Am Soc Echocardiogr. 2012;25:1319-1326.
Nemes A, Domsik P, Kalapos A, Lengyel C, Orosz A, Forster T. Comparison of three-dimensional speckle tracking echocardiography and two-dimensional echocardiography for evaluation of left atrial size and function in healthy volunteers (results from the MAGYAR-Healthy study). Echocardiography. 2014;31:865-871.
Perez de Isla L, Feltes G, Moreno J, et al. Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance. Eur Heart J Cardiovasc Imaging. 2014;15:793-799.
Buechel RR, Stephan FP, Sommer G, Bremerich J, Zellweger MJ, Kaufmann BA. Head-to-head comparison of two-dimensional and three-dimensional echocardiographic methods for left atrial chamber quantification with magnetic resonance imaging. J Am Soc Echocardiogr. 2013;26:428-435.
Sugimoto T, Robinet S, Dulgheru R, et al. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study. Eur Heart J Cardiovasc Imaging. 2018;19:630-638.
Roeh A, Schuster T, Jung P, Schneider J, Halle M, Scherr J. Two dimensional and real-time three dimensional ultrasound measurements of left ventricular diastolic function after marathon running: results from a substudy of the BeMaGIC trial. Int J Cardiovasc Imaging. 2019;35:1861-1869.
Zile MR, Brutsaert DL. New concepts in diastolic dysfunction and diastolic heart failure: Part I: diagnosis, prognosis, and measurements of diastolic function. Circulation. 2002;105:1387-1393.
Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16:233-270.
Zeidan Z, Erbel R, Barkhausen J, Hunold P, Bartel T, Buck T. Analysis of global systolic and diastolic left ventricular performance using volume-time curves by real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2003;16:29-37.
Armstrong WF, Ryan T. Feigenbaum's Echocardiography, 7th edn. Philadelphia, PA: Lippincott Williams & Wilkins; 2010.
Nakanishi K, Fukuda S, Watanabe H, et al. The utility of fully automated real-time three-dimensional echocardiography in the evaluation of left ventricular diastolic function. J Cardiol. 2015;66:50-56.
Tashiro H, Aoki T, Sadamatsu K, Ooe K, Yamawaki T, Sagara S. Evaluation of the left ventricular diastolic function using three-dimensional echocardiography. Echocardiography. 2008;25:968-973.
Yodwut C, Lang RM, Weinert L, Ahmad H, Mor-Avi V. Three-dimensional echocardiographic quantitative evaluation of left ventricular diastolic function using analysis of chamber volume and myocardial deformation. Int J Cardiovasc Imaging. 2013;29:285-293.

Auteurs

Luigi P Badano (LP)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.
Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.

Denisa Muraru (D)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.
Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.

Francesca Ciambellotti (F)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.

Sergio Caravita (S)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.
Department of Management, Information and Production Engineering, University of Bergamo, Dalmine, Italy.

Valentina Guida (V)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.

Michele Tomaselli (M)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.

Gianfranco Parati (G)

Department of Cardiological, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, San Luca Hospital, Milan, Italy.
Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH