Does actively enlarging socket volume during resting facilitate residual limb fluid volume recovery in trans-tibial prosthesis users?


Journal

Clinical biomechanics (Bristol, Avon)
ISSN: 1879-1271
Titre abrégé: Clin Biomech (Bristol, Avon)
Pays: England
ID NLM: 8611877

Informations de publication

Date de publication:
08 2020
Historique:
received: 14 11 2019
revised: 12 03 2020
accepted: 23 03 2020
pubmed: 4 7 2020
medline: 23 4 2021
entrez: 4 7 2020
Statut: ppublish

Résumé

Residual limb volume loss is a source of prosthetic socket fit problems in people with lower-limb amputation. The aim of this study was to investigate a novel volume recovery strategy for people with trans-tibial amputation. Test sockets for people with trans-tibial amputation were created that allowed panels of an adjustable socket and the underlying elastomeric liner to be pulled radially outward, using small motors mounted to the socket. One Control and one Intervention session were conducted with each participant. During Intervention sessions, panel-pull was executed during the sits of a multi-cycle sit/walk protocol. No panel-pull was executed during the Control sessions. Residual limb fluid volume was monitored in anterior and posterior regions using bioimpedance analysis. Results from 12 participants demonstrated that short-term (12 min after the intervention was applied) median posterior residual limb fluid volume change for Intervention (0.44%) was higher than that for Control (-0.02%) (P = .015). Long-term (40 min after the intervention was applied) median posterior residual limb fluid volume change for Intervention (0.95%) was higher than that for Control (-0.26%) (P = .002). If a panel-pull mechanism that was easy to assemble and operate could be created, then panel-pull may be an effective accommodation strategy to reduce daily limb volume loss in trans-tibial prosthesis users.

Sections du résumé

BACKGROUND
Residual limb volume loss is a source of prosthetic socket fit problems in people with lower-limb amputation. The aim of this study was to investigate a novel volume recovery strategy for people with trans-tibial amputation.
METHODS
Test sockets for people with trans-tibial amputation were created that allowed panels of an adjustable socket and the underlying elastomeric liner to be pulled radially outward, using small motors mounted to the socket. One Control and one Intervention session were conducted with each participant. During Intervention sessions, panel-pull was executed during the sits of a multi-cycle sit/walk protocol. No panel-pull was executed during the Control sessions. Residual limb fluid volume was monitored in anterior and posterior regions using bioimpedance analysis.
FINDINGS
Results from 12 participants demonstrated that short-term (12 min after the intervention was applied) median posterior residual limb fluid volume change for Intervention (0.44%) was higher than that for Control (-0.02%) (P = .015). Long-term (40 min after the intervention was applied) median posterior residual limb fluid volume change for Intervention (0.95%) was higher than that for Control (-0.26%) (P = .002).
INTERPRETATION
If a panel-pull mechanism that was easy to assemble and operate could be created, then panel-pull may be an effective accommodation strategy to reduce daily limb volume loss in trans-tibial prosthesis users.

Identifiants

pubmed: 32619870
pii: S0268-0033(20)30110-8
doi: 10.1016/j.clinbiomech.2020.105001
pii:
doi:

Types de publication

Journal Article Research Support, U.S. Gov't, Non-P.H.S.

Langues

eng

Sous-ensembles de citation

IM

Pagination

105001

Informations de copyright

Copyright © 2020 Elsevier Ltd. All rights reserved.

Auteurs

Brian G Larsen (BG)

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Jake B McLean (JB)

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Jacob T Brzostowski (JT)

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Ryan Carter (R)

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Katheryn J Allyn (KJ)

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Brian J Hafner (BJ)

Department of Rehabilitation Medicine, University of Washington, Seattle, WA, USA.

Joseph L Garbini (JL)

Department of Mechanical Engineering, University of Washington, Seattle, WA, USA.

Joan E Sanders (JE)

Department of Bioengineering, University of Washington, Seattle, WA, USA. Electronic address: jsanders@u.washington.edu.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH