In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array.
Halbach array
gradient design
low-field MRI
permanent magnets
sustainable imaging
Journal
Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245
Informations de publication
Date de publication:
01 2021
01 2021
Historique:
received:
07
02
2020
revised:
31
05
2020
accepted:
04
06
2020
pubmed:
7
7
2020
medline:
15
5
2021
entrez:
7
7
2020
Statut:
ppublish
Résumé
To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time. A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom-built gradient coils, RF coil, gradient amplifiers, and RF amplifier were integrated and tested on both phantoms and in vivo. Phantom results showed that the gradient nonlinearity in the y-direction and z-direction was less than 5% over a 15-cm FOV and did not need correcting. For the x-direction, it was significantly greater, but could be partially corrected in postprocessing. Three-dimensional in vivo scans of the brain of a healthy volunteer using a turbo spin-echo sequence were acquired at a spatial resolution of 4 × 4 × 4 mm in a time of about 2 minutes. The T This work has shown that it is possible to construct a low-field MRI unit with hardware components costing less than 10 000 Euros, which is able to acquire human images in vivo within a reasonable data-acquisition time. The system has a high degree of portability with magnet weight of approximately 75 kg, gradient and RF amplifiers each 15 kg, gradient coils 10 kg, and spectrometer 5 kg.
Identifiants
pubmed: 32627235
doi: 10.1002/mrm.28396
pmc: PMC7689769
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
495-505Informations de copyright
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
Références
MAGMA. 2002 Jan;13(3):177-85
pubmed: 11755094
J Magn Reson. 2008 Aug;193(2):274-85
pubmed: 18550402
Indian J Pediatr. 2019 Oct;86(10):952-960
pubmed: 31077004
Magn Reson Med. 2007 Feb;57(2):308-18
pubmed: 17260370
Magn Reson Med. 2015 Feb;73(2):872-83
pubmed: 24668520
Magn Reson Med. 2019 Nov;82(5):1946-1960
pubmed: 31231885
Magn Reson Med. 2021 Jan;85(1):495-505
pubmed: 32627235
Magn Reson Imaging. 2012 Oct;30(8):1134-42
pubmed: 22817958
J Magn Reson. 2014 Jan;238:52-62
pubmed: 24316186
J Magn Reson. 2017 Apr;277:143-148
pubmed: 28285144
J Magn Reson. 2019 Oct;307:106578
pubmed: 31470234
Childs Nerv Syst. 2011 Oct;27(10):1543-62
pubmed: 21928020
Neuroimage. 2018 Mar;168:59-70
pubmed: 27915120
Sensors (Basel). 2018 Jun 06;18(6):
pubmed: 29882810
MAGMA. 2018 Oct;31(5):665-676
pubmed: 29644479
Magn Reson Med. 1996 Oct;36(4):527-36
pubmed: 8892203
IEEE Trans Magn. 2018 Jan;54(1):
pubmed: 29749974
J Magn Reson. 2010 Nov;207(1):134-9
pubmed: 20864367
Acad Radiol. 2008 Jun;15(6):728-39
pubmed: 18486009
Sci Rep. 2019 Jul 18;9(1):10402
pubmed: 31320653
Magn Reson Med. 1997 May;37(5):785-92
pubmed: 9126954
Sci Rep. 2015 Oct 15;5:15177
pubmed: 26469756
Magn Reson Med. 2015 Mar;73(3):1120-4
pubmed: 24753306
Magn Reson Med. 1993 Aug;30(2):221-30
pubmed: 8366803
Tree Physiol. 2015 Apr;35(4):366-75
pubmed: 25595754
Med Phys. 1984 Jul-Aug;11(4):425-48
pubmed: 6482839
J Magn Reson Imaging. 2019 Jun;49(6):1528-1542
pubmed: 30637943