Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT. We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team. A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials.

Sections du résumé

BACKGROUND
Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT.
METHODS
We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team.
RESULTS
A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm
CONCLUSIONS
In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials.

Identifiants

pubmed: 32633055
doi: 10.1002/ccd.29104
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

E411-E417

Informations de copyright

© 2020 Wiley Periodicals LLC.

Références

Nishimura RA, Otto CM, Bonow RO, et al. 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the Management of Patients with Valvular Heart Disease: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines. J Am Coll Cardiol. 2017;70(2):252-289.
Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2017;38(36):2739-2791.
Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597-1607.
Leon MB, Smith CR, Mack MJ, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374(17):1609-1620.
Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 2019;380(18):1695-1705.
Grover FL, Vemulapalli S, Carroll JD, et al. 2016 annual report of the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. JACC (J Am Coll Cardiol). 2016;69(10):1215-1230.
Kundi H, Strom JB, Valsdottir LR, et al. Trends in isolated surgical aortic valve replacement according to hospital-based Transcatheter aortic valve replacement volumes. J Am Coll Cardiol Intv. 2018;11(21):2148-2156.
Chakravarty T, Søndergaard L, Friedman J, et al. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study. The Lancet. 2017;389(10087):2383-2392.
Makkar RR, Fontana G, Jilaihawi H, et al. Possible subclinical leaflet thrombosis in bioprosthetic aortic valves. N Engl J Med. 2015;373(21):2015-2024.
Overtchouk P, Guedeney P, Rouanet S, et al. Long-term mortality and early valve dysfunction according to anticoagulation use: the France TAVI registry. J Am Coll Cardiol. 2019;73(1):13-21.
Dangas GD, Tijssen JGP, Wöhrle J, et al. A controlled trial of rivaroxaban after Transcatheter aortic-valve replacement. N Engl J Med. 2020;382(2):120-129.
Zamorano JL, Badano LP, Bruce C, et al. EAE/ASE recommendations for the use of echocardiography in new Transcatheter interventions for Valvular heart disease. J Am Soc Echocardiogr. 2011;24(9):937-965.
Yanagisawa R, Tanaka M, Yashima F, et al. Early and late leaflet thrombosis after Transcatheter aortic valve replacement: a multicenter initiative from the OCEAN-TAVI registry. Circ Cardiovasc Interv. 2019;12(2):e007349.
Yanagisawa R, Hayashida K, Yamada Y, et al. Incidence, predictors, and mid-term outcomes of possible leaflet thrombosis after TAVR. J Am Coll Cardiol Img. 2016;10(1):1-11.
Pibarot P, Weissman NJ, Stewart WJ, et al. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort-a analysis. J Am Coll Cardiol. 2014;64(13):1323-1334.
van der Boon RM, Nuis R, Van Mieghem NM, et al. New conduction abnormalities after TAVI-frequency and causes. Nat Rev Cardiol. 2012;9(8):454-463.
Blanke P, Reinöhl J, Schlensak C, et al. Prosthesis oversizing in balloon-expandable Transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv. 2012;5(4):540-548.
Ducci A, Tzamtzis S, Mullen MJ, Burriesci G. Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI). J Heart Valve Dis. 2013;22(5):688.

Auteurs

Timothy F Simpson (TF)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Craig V Tuohy (CV)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Katherine Rajotte (K)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Harsh Golwala (H)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Cristina Fuss (C)

Department of Diagnostic Radiology, Oregon Health & Science University, Portland, Oregon, USA.

Howard K Song (HK)

Division of Cardiothoracic Surgery, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Firas Zahr (F)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Scott M Chadderdon (SM)

Division of Cardiovascular Medicine, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH