Prolonged Continuous Electrocardiographic Monitoring Prior to Transcatheter Aortic Valve Replacement: The PARE Study.
Action Potentials
Aged
Aged, 80 and over
Aortic Valve Stenosis
/ diagnostic imaging
Arrhythmias, Cardiac
/ diagnosis
Clinical Decision-Making
Electrocardiography, Ambulatory
Female
Heart Conduction System
/ physiopathology
Heart Rate
Humans
Male
Predictive Value of Tests
Prospective Studies
Risk Assessment
Risk Factors
Transcatheter Aortic Valve Replacement
/ adverse effects
Treatment Outcome
ambulatory electrocardiographic
aortic valve stenosis
arrhythmia
monitoring
pacemaker
transcatheter aortic valve replacement
Journal
JACC. Cardiovascular interventions
ISSN: 1876-7605
Titre abrégé: JACC Cardiovasc Interv
Pays: United States
ID NLM: 101467004
Informations de publication
Date de publication:
10 08 2020
10 08 2020
Historique:
received:
22
01
2020
revised:
16
03
2020
accepted:
24
03
2020
pubmed:
20
7
2020
medline:
1
4
2021
entrez:
20
7
2020
Statut:
ppublish
Résumé
This study sought to determine, using continuous electrocardiographic monitoring (CEM) pre-transcatheter aortic valve replacement (TAVR), the incidence and type of unknown pre-existing arrhythmic events (AEs) in TAVR candidates, and to evaluate the occurrence and impact of therapeutic changes secondary to the detection of AEs pre-TAVR. Scarce data exist on the arrhythmic burden of TAVR candidates (pre-procedure). This was a prospective study including 106 patients with severe aortic stenosis and no prior permanent pacemaker screened for TAVR. A prolonged (1 week) CEM was implanted within the 3 months pre-TAVR. Following heart team evaluation, 90 patients underwent elective TAVR. New AEs were detected by CEM in 51 (48.1%) patients, leading to a treatment change in 14 of 51 (27.5%) patients. Atrial fibrillation or tachycardia was detected in 8 of 79 (10.1%) patients without known atrial fibrillation or tachycardia, and nonsustained ventricular arrhythmias were detected in 31 (29.2%) patients. Significant bradyarrhythmias were observed in 22 (20.8%) patients, leading to treatment change and permanent pacemaker in 8 of 22 (36.4%) and 4 of 22 (18.2%) patients, respectively. The detection of bradyarrhythmias increased up to 30% and 47% among those patients with pre-existing first-degree atrioventricular block and right bundle branch block, respectively. Chronic renal failure, higher valve calcification, and left ventricular dysfunction determined (or tended to determine) an increased risk of AEs pre-TAVR (p = 0.028, 0.052, and 0.069, respectively). New onset AEs post-TAVR occurred in 22.1% of patients, and CEM pre-TAVR allowed early arrhythmia diagnosis in one-third of them. Prolonged CEM in TAVR candidates allowed identification of previously unknown AEs in nearly one-half of the patients, leading to prompt therapeutic measures (pre-TAVR) in about one-fourth of them. Pre-existing conduction disturbances (particularly right bundle branch block) and chronic renal failure were associated with a higher burden of AEs.
Sections du résumé
OBJECTIVES
This study sought to determine, using continuous electrocardiographic monitoring (CEM) pre-transcatheter aortic valve replacement (TAVR), the incidence and type of unknown pre-existing arrhythmic events (AEs) in TAVR candidates, and to evaluate the occurrence and impact of therapeutic changes secondary to the detection of AEs pre-TAVR.
BACKGROUND
Scarce data exist on the arrhythmic burden of TAVR candidates (pre-procedure).
METHODS
This was a prospective study including 106 patients with severe aortic stenosis and no prior permanent pacemaker screened for TAVR. A prolonged (1 week) CEM was implanted within the 3 months pre-TAVR. Following heart team evaluation, 90 patients underwent elective TAVR.
RESULTS
New AEs were detected by CEM in 51 (48.1%) patients, leading to a treatment change in 14 of 51 (27.5%) patients. Atrial fibrillation or tachycardia was detected in 8 of 79 (10.1%) patients without known atrial fibrillation or tachycardia, and nonsustained ventricular arrhythmias were detected in 31 (29.2%) patients. Significant bradyarrhythmias were observed in 22 (20.8%) patients, leading to treatment change and permanent pacemaker in 8 of 22 (36.4%) and 4 of 22 (18.2%) patients, respectively. The detection of bradyarrhythmias increased up to 30% and 47% among those patients with pre-existing first-degree atrioventricular block and right bundle branch block, respectively. Chronic renal failure, higher valve calcification, and left ventricular dysfunction determined (or tended to determine) an increased risk of AEs pre-TAVR (p = 0.028, 0.052, and 0.069, respectively). New onset AEs post-TAVR occurred in 22.1% of patients, and CEM pre-TAVR allowed early arrhythmia diagnosis in one-third of them.
CONCLUSIONS
Prolonged CEM in TAVR candidates allowed identification of previously unknown AEs in nearly one-half of the patients, leading to prompt therapeutic measures (pre-TAVR) in about one-fourth of them. Pre-existing conduction disturbances (particularly right bundle branch block) and chronic renal failure were associated with a higher burden of AEs.
Identifiants
pubmed: 32682674
pii: S1936-8798(20)30816-5
doi: 10.1016/j.jcin.2020.03.031
pii:
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1763-1773Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright © 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.