Novel use of an adjustable single 8-0 polypropylene suture of scleral fixation without conjunctival dissection.
8–0 polypropylene suture
Adjustable
Transscleral suture fixation
Without conjunctival dissection
Journal
BMC ophthalmology
ISSN: 1471-2415
Titre abrégé: BMC Ophthalmol
Pays: England
ID NLM: 100967802
Informations de publication
Date de publication:
25 Jul 2020
25 Jul 2020
Historique:
received:
01
11
2019
accepted:
07
07
2020
entrez:
27
7
2020
pubmed:
28
7
2020
medline:
15
5
2021
Statut:
epublish
Résumé
This report serves to describe the use of a novel adjustable single 8-0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach. In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8-0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8-0 polypropylene sutures were inserted into the eye guided by 10-0 polypropylene sutures of a long straight needle. The 8-0 suture was then used to fix the haptic IOs. Finally, these 8-0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence. For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR (p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up. An adjustable single 8-0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation. Retrospective case series study, not applicable. NCT04476264 .
Sections du résumé
BACKGROUND
BACKGROUND
This report serves to describe the use of a novel adjustable single 8-0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach.
METHODS
METHODS
In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8-0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8-0 polypropylene sutures were inserted into the eye guided by 10-0 polypropylene sutures of a long straight needle. The 8-0 suture was then used to fix the haptic IOs. Finally, these 8-0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence.
RESULTS
RESULTS
For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR (p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up.
CONCLUSIONS
CONCLUSIONS
An adjustable single 8-0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation.
TRIAL REGISTRATION
BACKGROUND
Retrospective case series study, not applicable. NCT04476264 .
Identifiants
pubmed: 32711502
doi: 10.1186/s12886-020-01558-y
pii: 10.1186/s12886-020-01558-y
pmc: PMC7382057
doi:
Substances chimiques
Polypropylenes
0
Banques de données
ClinicalTrials.gov
['NCT04476264']
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
304Références
Adv Med Sci. 2019 Mar;64(1):100-103
pubmed: 30580205
Br J Ophthalmol. 2016 May;100(5):638-43
pubmed: 26319945
Arch Ophthalmol. 1985 Dec;103(12):1816-21
pubmed: 3907604
Int Ophthalmol. 2019 Feb;39(2):455-460
pubmed: 29327291
BMC Ophthalmol. 2018 Apr 23;18(1):108
pubmed: 29688848
J Cataract Refract Surg. 2006 Nov;32(11):1907-12
pubmed: 17081894
Graefes Arch Clin Exp Ophthalmol. 2019 Jan;257(1):125-134
pubmed: 30413876
J Cataract Refract Surg. 2004 Apr;30(4):854-7
pubmed: 15093650
Surv Ophthalmol. 2005 Sep-Oct;50(5):429-62
pubmed: 16139038
BMC Ophthalmol. 2015 Oct 02;15:127
pubmed: 26432550
Ophthalmic Surg Lasers Imaging. 2004 Sep-Oct;35(5):379-82
pubmed: 15497548
J Cataract Refract Surg. 2016 Jul;42(7):955-60
pubmed: 27492091
Int Ophthalmol. 1986 May;9(2-3):151-60
pubmed: 3522455
J Cataract Refract Surg. 2018 Dec;44(12):1421-1425
pubmed: 30314754
Ophthalmology. 2014 Jan;121(1):61-66
pubmed: 24148655
Am J Ophthalmol. 2018 Nov;195:36-42
pubmed: 30071212
Am J Ophthalmol. 2006 Feb;141(2):308-312
pubmed: 16458685
J Cataract Refract Surg. 1997 Nov;23(9):1289-94
pubmed: 9423897
Indian J Ophthalmol. 2019 Jan;67(1):64-68
pubmed: 30574895
Jpn J Ophthalmol. 2018 May;62(3):365-372
pubmed: 29464488
J Cataract Refract Surg. 2006 Feb;32(2):200-2
pubmed: 16564993
J Cataract Refract Surg. 2014 Apr;40(4):609-17
pubmed: 24560552