Transradial Crossover Balloon Occlusion Technique for Primary Access Hemostasis During Transcatheter Aortic Valve Replacement: Initial Experience With the Oceanus 140 cm and 200 cm Balloon Catheters.


Journal

The Journal of invasive cardiology
ISSN: 1557-2501
Titre abrégé: J Invasive Cardiol
Pays: United States
ID NLM: 8917477

Informations de publication

Date de publication:
Aug 2020
Historique:
entrez: 2 8 2020
pubmed: 2 8 2020
medline: 21 8 2021
Statut: ppublish

Résumé

The crossover balloon occlusion technique (CBOT) facilitates primary access hemostasis in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). The CBOT is usually performed through the contralateral femoral artery. The aim of this study was to evaluate, in patients undergoing TAVR, the safety and feasibility of transradial CBOT using the new Oceanus balloon dilatation catheter (iVascular). This multicenter study included 104 patients (mean age, 81 ± 7 years; 43% women) undergoing transfemoral TAVR. A modified CBOT through the radial artery was performed in all patients with the Oceanus balloon catheter. Data regarding transradial CBOT, balloon performance, vascular complications, and 30-day clinical events were recorded. Up to 21% of patients had a height >170 cm and 17% presented with severe aortic/iliofemoral tortuosity. The transradial CBOT (left radial 74%, right radial 26%) was performed using either the 140 cm Oceanus (37.5%) or the 200 cm Oceanus (62.5%) balloon catheter. The balloon reached the femoral artery in all patients, and balloon inflation achieved an appropriate vessel closure in 98%. There were no complications related to the balloon catheter, and only 1 patient (1.0%) suffered a minor vascular complication related to the secondary radial access. The 30-day rates of primary access major vascular complications and death were 3.8% and 1.9%, respectively. In patients undergoing transfemoral TAVR, transradial CBOT with the Oceanus balloon dilatation catheter was feasible and safe. A balloon length up to 200 cm allowed the use of this technique (from right or left radial access) in all patients regardless of patient height or the presence of a challenging vascular anatomy.

Identifiants

pubmed: 32737263

Types de publication

Journal Article Multicenter Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

283-288

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH