CAD/CAM complete dentures have increased in popularity and a wide variety of systems are currently available. These prostheses present many advantages for clinicians, technicians and patients. Subtractive manufacturing is used by most of the available systems while a few manufacturers use an additive manufacturing technique. This article describes the currently available systems and materials available for the fabrication of CAD/CAM complete dentures and reviews the literature relative to their physical properties. A comprehensive review of the literature was completed to enumerate the currently available techniques to fabricate CAD/CAM complete dentures and discuss their physical properties. A search of English language peer-reviewed literature was undertaken using MEDLINE and PubMed on research articles published between 2000 and 2019. A hand search of relevant dental journals was also completed. The literature indicates the physical properties of CAD/CAM milled poly(methylmethacrylate) or PMMA as it is commonly described is superior to conventionally processed PMMA for the fabrication of complete dentures. The incorporation of CAD/CAM technology into complete denture design and fabrication streamlines the clinical and laboratory processes and provides improved physical properties that enhance denture quality.

Identifiants

pubmed: 32844510
doi: 10.1111/jopr.13243
doi:

Substances chimiques

Methylmethacrylate 196OC77688

Types de publication

Journal Article Review

Langues

eng

Pagination

113-124

Informations de copyright

© 2020 by the American College of Prosthodontists.

Références

Rekow D: Computer-aided design and manufacturing in dentistry: a review of the state of the art. J Prosthet Dent 1987;58:512-516
Al Mardini M, Ercoli C, Graser GN: A technique to produce a mirror-image wax pattern of an ear using rapid prototyping technology. J Prosthet Dent 2005;94:195-198
Sarment DP, Sukovic P, Clinthorne N: Accuracy of implant placement with stereolithographic surgical guide. Int J Oral Maxillofac Implants 2003;18:571-577
Mörmann WH: The origin of the Cerec method: a personal review of the first 5 years. Int J Comput Dent 2004;7:11-24
Ettinger RL, Beck JD, Jakobsen J: Removable prosthodontic treatment needs: a survey. J Prosthet Dent 1984;51:419-427
Grant GT, Campbell SD, Masri RM: The American College of Prosthodontists Digital Dentistry Glossary Development Task Force. Glossary of digital dental terms. J Prosthodont 2016;25:S2-S9
Bahman AS, Ianuzzo F: Computer-aided engineering simulations in Wide Bandgap Power Semiconductor Packaging. United Kingdom, Woodhead Publishing, 2018, pp 199-223
Maeda Y, Minoura M, Tsutsumi S, et al: A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994;7:17-21
Kawahata N, Ono H, Nishi Y, et al: Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil 1997;24:540-548
Sun Y, Lü P, Wang Y: Study on CAD&RP for removable complete denture. Comput Methods Prog Biomed 2009;93:266-272
Wu J, Gao B, Tan H, et al: A feasibility study on laser rapid forming of a complete titanium denture base plate. Lasers Med Sci 2010;25:309-315
Kanazawa M, Inokoshi M, Minakuchi S, et al: Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-96
Goodacre CJ, Garbacea A, Naylor WP, et al: CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46
Inokoshi M, Kanazawa M, Minakuchi S: Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J 2012;31:40-46
Bilgin MS, Erdem A, Aglarci OS, et al: Fabricating complete dentures with CAD/CAM and RP technologies. J Prosthodont 2015;24:576-579
Baba NZ, Goodacre CJ, Kattadiyil MT: CAD/CAM removable prosthodontics. In: Masri R, Driscoll CF (eds): Clinical Applications of Digital Technology, Hoboken, NJ: John Wiley & Sons, Inc. 2015
Baba NZ: Materials and processes for CAD/CAM complete denture fabrication. Curr Oral Health Rep 2016;3:203-208
Baba NZ, AlRumaih HS, Goodacre BJ, et al: Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64:23-28
Steinmassl PA, Klaunzer F, Steinmassl O, et al: Evaluation of currently available CAD/CAM denture systems. Int J Prosthodont 2017;30:116-122
Schiffman P: Relation of the maxillary canines to the incisive papilla. J Prosthet Dent 1964;14:469-447
Martone AL: Clinical applications of concepts of functional anatomy and speech science to complete denture prosthodontics. Part VIII. The final phases of denture construction. J Prosthet Dent 1962;12:817-834
Vig RG: The denture look. J Prosthet Dent 1961;11:9-15
Mavroskoufis F, Ritchie GM: Nasal width and incisive papilla as guides for the selection and arrangement of maxillary anterior teeth. J Prosthet Dent 1981;45:592-597
Goodacre BJ, Goodacre CJ, Baba NZ: Using intraoral scanning to capture complete denture impressions, tooth positions, and centric relation records. Int J Prosthodont 2018;31(4):377-381
Alammari MR: The influence of polishing techniques on pre-polymerized CAD/CAM acrylic resin denture bases. Electron Phys 2017;25:5452-5458
Steinmassl O, Dumfarht H, Grunert I, et al: Influence of CAD/CAM fabrication on denture surface properties. J Oral Rehabil 2018;45:406-413
Arslan M, Murat S, Alp G, et al: Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures. Int J Comput Dent 2018;21:31-40
Sipahi C, Anil N, Bayramli E: The Effect of acquired salivary pellicle on the surface free energy and wettability of different denture base materials. J Dent 2001;29:197-204
Gesser HD, Castaldi CR: The preparation and evaluation of wetting dentures for adhesion and retention. J Prosthet Dent 1971;25:236-243
Monsénégo P, Proust J: Complete denture retention. Part I: Physical analysis of the mechanism. Hysteresis of the solid-liquid contact angle. J Prosthet Dent 1989;62:189-196
Al-Fouzan A, Al-mejrad LA, Albarrag AM: Adherence of Candida to complete denture surfaces: a comparison of conventional and CAD/CAM complete dentures. J Adv Prosthodont 2017;9:402-408
Steinmassl O, Dumfarht H, Grunert I, et al: CAD/CAM procedures dentures with improved fit. Clin Oral Investig 2018 Nov;22:2829-2835
Alp G, Johnston WM, Yilmaz B: Optical properties and surface roughness or prepolymerized poly(methyl methacrylate) denture base materials. J Prosthet Dent 2019;121:347-352
Austin AT, Basker RM: The level of residual monomer in acrylic denture base materials with particular reference to a modified method of analysis. Br Dent J 1980;149:281-286
Bettencourt AF, Neves CB, de Almeida MS, et al: Biodegradation of acrylic based resins: a review. Dent Mater 2010;26(5):e171-80
Singh RD, Gautam R, Siddhartha R, et al: High performance liquid chromatographic determination od residual monomer released from heat-cured acrylic resin. An in vitro study. J Prosthodont 2013;22:358-361
Murakami N, Wakabayashi N, Matsushima R, et al: Effect of high-pressure polymerization on mechanical properties of PMMA denture base resin. J Mech Behav Biomed Mater 2013;20:98-104
Ayman AD: The residual monomer content and mechanical properties of CAD/CAM resins used in the fabrication of complete dentures as compared to heat cured resins. Electron Physician 2017;9:4766-4722
Ali IL, Yunus N, Abu-Hassan MI: Hardness, flexural strength, and flexural modulus comparisons of three differently cured denture base systems. J Prosthodont 2008;17:545-549
Steinmassl PA, Wiedemair V, Huck C, et al: Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig 2017;21:1697-1705
Berger JC, Driscoll CF, Romberg E, et al: Surface roughness of denture base acrylic resins after processing and after polishing. J Prosthodont 2006;15:180-186
Bollen CM, Lambrechts P, Quirynen M: Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater 1997;13:258-269
Morgan TD, Wilson M: The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermentor. J Appl Microbiol 2001;91:47-53
Srinivasan M, Gjengedal H, Cattani-Lorente M, et al: CAD/CAM milled complete removable dental prostheses: an in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent Mater J 2018;37:526-533
Woelfel JB, Paffenbarger GC, Sweeney WT: Dimensional changes occurring in dentures during processing. J AM Dent Assoc 1960;61:413-430
Wong DM, Cheng LY, Chow TW, et al: Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures. J Prosthet Dent 1999;81:300-304
Goodacre BJ, Goodacre CJ, Baba NZ, et al: Comparison of base adaptation between CAD/CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-256
Srinivasan M, Cantin Y, Mehl A, et al: CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig 2017;21:2007-2019
Kalberer N, Mehl A, Schimmel M, et al: CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness. J Prosthet Dent 2019;121:637-643
Lee S, Hong SJ, Paek J, et al: Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method. J Adv Prosthodont 2019;11:55-64
Yoon HI, Hwang HJ, Ohkubo C, et al: Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing. J Prosthet Dent 2018;120:919-926
Hwang HJ, Lee SJ, Park EJ, et al: Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using light processing. J Prosthet Dent 2019;121:110-117
Tasaka A, Matsunaga S, Odaka K, et al: Accuracy and retention of denture base fabricated by heat curing and additive manufacturing. J Prosthodont Res 2019;63:85-89
McLaughlin JB, Ramos V Jr, Dickinson DP: Comparison of fit of dentures fabricated by traditional techniques versus CAD/CAM technology. J Prosthodont 2019;28:428-435
AlHelal A, AlRumaih HS, Kattadiyil MT, et al: Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent 2017;117:233-238
AlRumaih HS, AlHelal A, Baba NZ, et al: Effects of denture adhesive on the retention of milled and heat-activated maxillary denture base: a clinical study. J Prosthet Dent 2018;120:361-366
Atkinson HF, Grant AA: An investigation into tooth movement during the packing and polymerizing of acrylic resin denture base materials. Aust Dent J 1962;7:101-108
Grant AA: Effect of the investment procedure on tooth movement. J Prosthet Dent 1962;12:1053-1058
Wimmer T, Eichberger M, Lümkemann N, et al: Accuracy of digitally fabricated trial dentures. J Prosthet Dent 2018;119:942-947
Yamamoto S, Kanazawa M, Iwaki M, et al: Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014;52:1-7
Yamamoto S, Kanazawa M, Hirayama D, et al: In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures. Comput Biol Med 2016;68:84-89
Goodacre BJ, Goodacre CJ, Baba NZ, et al: Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2018;119:108-115
Imirzalioglu P, Karacaer O, Yilmaz B, et al: Color stability of denture acrylic resins and a soft lining material against tea, coffee, and nicotine. J Prosthodont 2010;19:118-124
Zuo W, Feng D, Song A, et al: Effects of organic-inorganic hybrid coating on the color stability of denture base resins. J Prosthet Dent 2016;115:103-108
Al-Qarni FD, Goodacre CJ, Kattadiyil MT, et al: Stainability of acrylic resin materials used in CAD/CAM and conventional complete dentures. J Prosthet Dent 2020;123(6):880-887
Steinmassl O, Offermans V, Stöckl W, et al: In vitro analysis of the fracture resistance of CAD/CAM denture base resins. Materials (Basel) 2018 Mar 8;11(3). pii: E401. https://doi.org/10.3390/ma11030401
Koike T, Ishizaki K, Ogami K, et al: Influence of anterior palatal coverage on perception and retention in complete dentures. J Prosthet Dent 2011;105:272-279
Pacquet W, Benoit A, Hatège-Kimana C, et al: Mechanical properties of CAD/CAM denture base resins. Int J Prosthodont 2019;32:104-106
Al-Dwairi ZN, Tahboub KY, Baba NZ, et al: A comparison of the flexural and impact strengths and flexural modulus of CAD/CAM and conventional heat-cured polymathy methacrylate (PMMA). J Prosthodont 2018;29(4):341-349
Park J-M, Ahn J-S, Cha H-S, et al: Wear resistance of 3D printing resin material opposing zirconia and metal antagonists. Materials (Basel) 2018;11:1043; https://doi.org/10.3390/ma11061043
Chung Y-J, Park J-M, Kim T-H, et al: 3D printing of resin material for denture artificial teeth: chipping and indirect tensile fracture resistance. Materials (Basel) 2018;11:1798; https://doi.org/10.3390/ma11101798
Kattadiyil MT, Jekki R, Goodacre CJ, et al: Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent 2015;114:818-825
Bidra AS, Farrell K, Burnham D, et al: Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent 2016;115:578-586
Saponaro PC, Yilmaz B, Heshmati RH, et al: Clinical performance of CAD-CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent 2016;116:431-435
Saponaro PC, Yilmaz B, Johnston W, et al: Evaluation of patient experience and satisfaction with CAD-CAM-fabricated complete dentures: a retrospective survey study. J Prosthet Dent 2016;116:524-528
Schlenz MA, Schmidt A, Wöstmann B, et al: Clinical performance of computer-engineered complete dentures: a retrospective pilot study. Quintessence Int 2019;50(9):706-711
Srinivasan M, Schimmel M, Naharro M, et al: CAD/CAM milled removable complete dentures: time and cost estimation study. J Dent 2019;8:75-79
Bilgin MS, Baytaroğlu EN, Erdem A et al: A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication. Eur J Dent 2016;10:286-291

Auteurs

Nadim Z Baba (NZ)

Advanced Education Program in Implant Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA.

Brian J Goodacre (BJ)

Division of General Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA.

Charles J Goodacre (CJ)

Advanced Education in Implant Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA.

Frauke Müller (F)

Clinique Universitaire de Médecine Dentaire, Division de Gérodontologie et Prothèse adjointe, Université de Genève, Switzerland.

Stephen Wagner (S)

Private Practice of Prosthodontics, Albuquerque, NM.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH