The effect of the design of a mandibular implant-supported zirconia prosthesis on stress distribution.


Journal

The Journal of prosthetic dentistry
ISSN: 1097-6841
Titre abrégé: J Prosthet Dent
Pays: United States
ID NLM: 0376364

Informations de publication

Date de publication:
Mar 2021
Historique:
received: 28 02 2020
revised: 19 05 2020
accepted: 19 05 2020
pubmed: 8 9 2020
medline: 11 3 2021
entrez: 7 9 2020
Statut: ppublish

Résumé

Prosthetic complications have been frequently reported in implant-supported complete-arch prosthesis. Prosthetic restorations designed with an all-on-four treatment concept and fabricated from zirconia ceramic may be used to overcome these problems. The purpose of this biomechanical study was to evaluate the effects of cantilever length and inclination of implant on the stress distribution in bone tissue, implant, and a monolithic zirconia ceramic-lithium disilicate glass-ceramic superstructure for all-on-four prosthesis. All-on-four mandibular prosthesis fabricated from a zirconia and lithium disilicate glass-ceramic (LDGC) superstructure was designed with cantilever lengths of either 5 mm or 9 mm and posterior implants with a distal tilt of either 15 or 30 degrees. Stresses were evaluated with a simulated application of a static load of 600 N. Increasing implant inclination from 15 to 30 degrees led to a decrease in maximum principal stress (MaxPS) values of approximately 4 to 7 MPa in cortical bone around all implants except the right anterior implant in the designs with short cantilevers and an increase in MaxPS values (approximately 3 to 19 MPa) in the same places in the designs with the long cantilevers. Increasing cantilever length from 5 to 9 mm resulted in an increase in minimum principal stress (MinPS) values of approximately 3 to 13 MPa in the cortical bone surrounding all posterior implants. In the designs with the long cantilever, MaxPS values increased approximately 3 to 4 MPa in spongy bone adjacent to the right posterior implant. An increase in cantilever length also led to higher vMS values at the first and second implant grooves in the right posterior implant in the design with the 15-degree implant tilt. An increase in implant inclination in the design with the short cantilever resulted in lower vMS values at the apex and all grooves of the left posterior implant, whereas in the design with the long cantilever, an increase in implant inclination resulted in lower stress values in the first and second grooves of the same implant. An increase in implant inclination led to in an increase in vMS values in the core structure. In zirconia ceramic restorations by using an all-on-four design with an LDGC superstructure, short cantilevers may be preferable because they result in a more favorable distribution of stress than long cantilevers. An increase in implant angulation from 15 to 30 degrees decreased MaxPS values in cortical bone.

Identifiants

pubmed: 32893017
pii: S0022-3913(20)30427-3
doi: 10.1016/j.prosdent.2020.05.027
pii:
doi:

Substances chimiques

Dental Implants 0
Zirconium C6V6S92N3C
zirconium oxide S38N85C5G0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

502.e1-502.e11

Informations de copyright

Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Auteurs

Perihan Oyar (P)

Associate Professor, Dental Prosthetics Technology, Health Services Vocational School, Hacettepe University, Ankara, Turkey. Electronic address: poyar73@gmail.com.

Rukiye Durkan (R)

Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Afyon Kocatepe University, Afyonkarahisar, Turkey.

Gonca Deste (G)

Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey.

Articles similaires

Calcium Carbonate Sand Powders Construction Materials Materials Testing

Characterization of 3D printed composite for final dental restorations.

Lucas Eigi Borges Tanaka, Camila da Silva Rodrigues, Manassés Tércio Vieira Grangeiro et al.
1.00
Composite Resins Materials Testing Printing, Three-Dimensional Surface Properties Flexural Strength
Humans Male Female Transcatheter Aortic Valve Replacement Finite Element Analysis

Classifications MeSH