Large medial proximal tibial angles cause excessively medial tibiofemoral contact forces and abnormal knee kinematics following open-wedge high tibial osteotomy.
Knee kinematics
Medial collateral ligament tension
Medial proximal tibial angle
Open-wedge high tibial osteotomy
Tibiofemoral contact force
Journal
Clinical biomechanics (Bristol, Avon)
ISSN: 1879-1271
Titre abrégé: Clin Biomech (Bristol, Avon)
Pays: England
ID NLM: 8611877
Informations de publication
Date de publication:
12 2020
12 2020
Historique:
received:
22
05
2020
revised:
26
08
2020
accepted:
28
09
2020
pubmed:
15
10
2020
medline:
24
4
2021
entrez:
14
10
2020
Statut:
ppublish
Résumé
Recurrent varus deformity and poor outcome sometimes occur following open-wedge high tibial osteotomy, but the mechanism remains unclear. The hypothesis of this study was that an excessively large medial proximal tibial angle with lateral joint surface inclination can worsen postoperative knee biomechanics. A computer-simulated knee model was validated based on a volunteer knee. Osteotomy models with medial proximal tibial angles ranging from 90° to 97° in 1° increments were developed. Varus alignment correction of the distal femur was performed in each model to maintain identical coronal alignment passing through a point 62.5% lateral to the tibial plateau. The peak tibiofemoral contact forces and knee kinematics were compared in each model during walking and squatting. All the osteotomy models demonstrated higher peak contact forces on the lateral tibiofemoral joints than on the medial tibiofemoral joints during walking. However, larger medial proximal tibial angles caused excessive increases in medial tibiofemoral contact forces, and the dominant tibiofemoral contact forces shifted to the medial side. Increased medial proximal tibial angles also caused progressive medial collateral ligament tension in knee flexion, but partial medial collateral ligament release effectively reduced medial tibiofemoral contact forces. Models with large medial proximal tibial angles showed nonphysiological roll-forward of the lateral femoral condyle during squatting and no screw-home movement around knee extension. Excessively large medial proximal tibial angles following open-wedge high tibial osteotomy resulted in increased medial tibiofemoral contact forces and abnormal knee kinematics during knee flexion due to medial joint line elevation and ligament imbalance.
Sections du résumé
BACKGROUND
Recurrent varus deformity and poor outcome sometimes occur following open-wedge high tibial osteotomy, but the mechanism remains unclear. The hypothesis of this study was that an excessively large medial proximal tibial angle with lateral joint surface inclination can worsen postoperative knee biomechanics.
METHODS
A computer-simulated knee model was validated based on a volunteer knee. Osteotomy models with medial proximal tibial angles ranging from 90° to 97° in 1° increments were developed. Varus alignment correction of the distal femur was performed in each model to maintain identical coronal alignment passing through a point 62.5% lateral to the tibial plateau. The peak tibiofemoral contact forces and knee kinematics were compared in each model during walking and squatting.
FINDINGS
All the osteotomy models demonstrated higher peak contact forces on the lateral tibiofemoral joints than on the medial tibiofemoral joints during walking. However, larger medial proximal tibial angles caused excessive increases in medial tibiofemoral contact forces, and the dominant tibiofemoral contact forces shifted to the medial side. Increased medial proximal tibial angles also caused progressive medial collateral ligament tension in knee flexion, but partial medial collateral ligament release effectively reduced medial tibiofemoral contact forces. Models with large medial proximal tibial angles showed nonphysiological roll-forward of the lateral femoral condyle during squatting and no screw-home movement around knee extension.
INTERPRETATION
Excessively large medial proximal tibial angles following open-wedge high tibial osteotomy resulted in increased medial tibiofemoral contact forces and abnormal knee kinematics during knee flexion due to medial joint line elevation and ligament imbalance.
Identifiants
pubmed: 33053468
pii: S0268-0033(20)30309-0
doi: 10.1016/j.clinbiomech.2020.105190
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
105190Informations de copyright