Diagnostic Characteristics of 3-Parameter and 2-Parameter Equations for the Calculation of a Combined Indicator of Vitamin B12 Status to Predict Cobalamin Deficiency in a Large Mixed Patient Population.


Journal

Clinical laboratory
ISSN: 1433-6510
Titre abrégé: Clin Lab
Pays: Germany
ID NLM: 9705611

Informations de publication

Date de publication:
01 Oct 2020
Historique:
entrez: 19 10 2020
pubmed: 20 10 2020
medline: 22 6 2021
Statut: ppublish

Résumé

A combined indicator for the determination of vitamin B12 status (4cB12) that employs four markers of vitamin B12 status (i.e., holotranscobalamin, HoloTC; vitamin B12, B12; methyl malonic acid, MMA; and homocysteine, Hcy) has been proposed for the comprehensive assessment of B12 status. We aimed to compare recently published 2- (2cB12) and 3-parameter (3cB12) cB12 equations missing one or two markers of B12 status with the established four-parameter cB12 (4cB12). In 3,614 routine samples in which HoloTC, B12, MMA, Hcy and serum folate were measured, cB12 was assessed with 4cB12, as well as with four 3cB12 and six 2cB12 equations. Diagnostic accuracy (AUC) curves were calculated by receiver operating characteristic (ROC) curve analysis with the four-parameter equation (4cB12) as an index. Furthermore, we investigated whether calculating cB12 in addition to a 2-step algorithm employing the same parameters would add diagnostic value for the diagnosis of vitamin B12 deficiency. HoloTC showed the highest diagnostic accuracy among the single markers (AUC = 0.94). The cB12 equation using HoloTC and MMA (2cB12HoloTC/MMA) had the highest AUC among the 2-parameter equations (0.98). Among the 3-parameter equations, 3cB12HoloTC/MMA/Hcy and 3cB12HoloTC/B12/MMA revealed an AUC of 0.99, which was significantly higher than that of 2cB12HoloTC/MMA (p < 0.01). Calculating 2cB12HoloTC/MMA in addition to using a stepwise algorithm employing HoloTC and MMA for diagnosis of vitamin B12 deficiency increased the positive likelihood ratio from 12.1 to 42.6. cB12 calculated with two or three markers of B12 status provides a good approximation of the 4cB12 equation. A 2cB12 equation employing the same parameters improved diagnostic accuracy compared to the use of a 2-step diagnostic algorithm alone. Our results suggest, that laboratories should consider enriching their reports by additionally reporting a corresponding 2cB12 or 3cB12 to results obtained in stepwise diagnostic algorithms.

Sections du résumé

BACKGROUND BACKGROUND
A combined indicator for the determination of vitamin B12 status (4cB12) that employs four markers of vitamin B12 status (i.e., holotranscobalamin, HoloTC; vitamin B12, B12; methyl malonic acid, MMA; and homocysteine, Hcy) has been proposed for the comprehensive assessment of B12 status. We aimed to compare recently published 2- (2cB12) and 3-parameter (3cB12) cB12 equations missing one or two markers of B12 status with the established four-parameter cB12 (4cB12).
METHODS METHODS
In 3,614 routine samples in which HoloTC, B12, MMA, Hcy and serum folate were measured, cB12 was assessed with 4cB12, as well as with four 3cB12 and six 2cB12 equations. Diagnostic accuracy (AUC) curves were calculated by receiver operating characteristic (ROC) curve analysis with the four-parameter equation (4cB12) as an index. Furthermore, we investigated whether calculating cB12 in addition to a 2-step algorithm employing the same parameters would add diagnostic value for the diagnosis of vitamin B12 deficiency.
RESULTS RESULTS
HoloTC showed the highest diagnostic accuracy among the single markers (AUC = 0.94). The cB12 equation using HoloTC and MMA (2cB12HoloTC/MMA) had the highest AUC among the 2-parameter equations (0.98). Among the 3-parameter equations, 3cB12HoloTC/MMA/Hcy and 3cB12HoloTC/B12/MMA revealed an AUC of 0.99, which was significantly higher than that of 2cB12HoloTC/MMA (p < 0.01). Calculating 2cB12HoloTC/MMA in addition to using a stepwise algorithm employing HoloTC and MMA for diagnosis of vitamin B12 deficiency increased the positive likelihood ratio from 12.1 to 42.6.
CONCLUSIONS CONCLUSIONS
cB12 calculated with two or three markers of B12 status provides a good approximation of the 4cB12 equation. A 2cB12 equation employing the same parameters improved diagnostic accuracy compared to the use of a 2-step diagnostic algorithm alone. Our results suggest, that laboratories should consider enriching their reports by additionally reporting a corresponding 2cB12 or 3cB12 to results obtained in stepwise diagnostic algorithms.

Identifiants

pubmed: 33073953
doi: 10.7754/Clin.Lab.2020.200130
doi:

Substances chimiques

Biomarkers 0
Transcobalamins 0
Homocysteine 0LVT1QZ0BA
Methylmalonic Acid 8LL8S712J7
Vitamin B 12 P6YC3EG204

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH