Effect of surface treatment and cleaning on the bond strength to polymer-infiltrated ceramic network CAD-CAM material.
Journal
The Journal of prosthetic dentistry
ISSN: 1097-6841
Titre abrégé: J Prosthet Dent
Pays: United States
ID NLM: 0376364
Informations de publication
Date de publication:
Nov 2021
Nov 2021
Historique:
received:
10
07
2018
revised:
06
08
2020
accepted:
07
08
2020
pubmed:
31
10
2020
medline:
10
11
2021
entrez:
30
10
2020
Statut:
ppublish
Résumé
Optimal composite resin bonds to polymer-infiltrated ceramic network (PICN) computer-aided design and computer-aided manufacturing (CAD-CAM) materials are essential for clinical success. However, comparative bond strength studies on the influence of different etching and cleaning methods on these materials are lacking. The purpose of this in vitro study was to measure and compare the microshear bond strength (μSBS) of a composite resin cement with that of a PICN material after different surface treatment and cleaning methods. Seventy specimens of a CAD-CAM PICN were divided into 7 groups (n=10): no treatment (control), hydrofluoric acid etching for 20 seconds (HF20), 60 seconds (HF60), 120 seconds (HF120), HF20 + phosphoric acid for 60 seconds and ultrasonic bath for 5 minutes, HF60 + PH, and HF120 + PH. After surface treatment, a silane coupling agent and composite resin cement were applied. Microshear bond strength was determined, and data were analyzed with 1-way ANOVA and Tukey post hoc multiple comparison tests (α=.05). All HF acid treatments resulted in a significant increase in bond strength to the polymer-infiltrated ceramic network material (P=.02). Bond strength values for HF etching for 20 seconds were significantly lower than those for 60 seconds and 120 seconds (P=.034). No difference was found between 60 seconds and 120 seconds of HF etching time (P=.986). Additional surface treatment with phosphoric acid 60 seconds and ultrasonic bath 5 minutes did not improve the bond strength beyond values obtained by hydrofluoric acid treatment only (P=.834). Most failures were cohesive. Acid etching and surface treatment have significant effects on composite resin bond strength to a PICN CAD-CAM material. HF etching for 60 seconds or 120 seconds provides the highest bond strengths. Cleaning methods after etching did not have any significant effect on bond strength.
Identifiants
pubmed: 33121822
pii: S0022-3913(20)30475-3
doi: 10.1016/j.prosdent.2020.08.016
pii:
doi:
Substances chimiques
Polymers
0
Resin Cements
0
Silanes
0
Dental Porcelain
12001-21-7
Hydrofluoric Acid
RGL5YE86CZ
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
698-702Informations de copyright
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.