Résumé
The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by EBRA (Einzel-Bild-Roentgen-Analyse) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 1 milimeter (mm) within the first 2 years after surgery. In this study, we investigated the migration behaviour of an uncemented press-fit cup after 2 years follow-up. Applying a retrospective study design, we reviewed all consecutive patients who received an uncemented press-fit cup at our Department between 2013 and 2018. A total of 484 patients were identified. We reviewed medical histories and performed radiological measurements using EBRA-Cup software. EBRA measurements and statistical investigations were performed by two independent investigators. A total of 165 cups in 159 patients (female: 90; male: 69) met our inclusion criteria. Mean age at surgery was 66.7 (range 18.4-90.5) years. EBRA migration analysis showed a mean total migration of 0.7 mm (range 0.0-6.3) over our follow-up period of 2 years. Of the investigated cups, 53.2% showed less than 1 mm migration in the investigated follow-up period. In conclusion, the Pinnacle cup used in our study provides low mean migration at final follow-up. Based on the assumption of secondary stabilization, good long-term outcome of the Pinnacle cup can be expected. Number: 20181024-1875; Date: 2018-09-20.
Identifiants
pubmed: 33128095
doi: 10.1007/s00402-020-03648-4
pii: 10.1007/s00402-020-03648-4
pmc: PMC7815589
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
149-154Références
Johnsen SP, Sørensen HT, Lucht U, Søballe K, Overgaard S, Pedersen AB (2006) Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms. A nationwide Danish follow-up study including 36,984 patients. J Bone JtSurg Br 88:1303–1308. https://doi.org/10.1302/0301-620X.88B10.17399
doi: 10.1302/0301-620X.88B10.17399
Stocks GW, Freeman MA, Evans SJ (1995) Acetabular cup migration. Prediction of aseptic loosening. J Bone JtSurg Br 77:853–861
doi: 10.1302/0301-620X.77B6.7593094
Ilchmann T, Markovic L, Joshi A, Hardinge K, Murphy J, Wingstrand H (1998) Migration and wear of long-term successful Charnley total hip replacements. J Bone JtSurg Br 80:377–381. https://doi.org/10.1302/0301-620x.80b3.8455
doi: 10.1302/0301-620x.80b3.8455
Wyss T, Kägi P, Mayrhofer P, Nötzli H, Pfluger D, Knahr K (2013) Five-year results of the uncemented RM pressfit cup clinical evaluation and migration measurements by EBRA. J Arthroplasty 28:1291–1296. https://doi.org/10.1016/j.arth.2012.11.004
doi: 10.1016/j.arth.2012.11.004
pubmed: 23523483
Ilchmann T, Neher S, Maurer F, Weise K (2007) Modes of failure of a threaded acetabular cup: a radiographic study with EBRA of 42 revised cups. Int Orthop 31:211–216. https://doi.org/10.1007/s00264-006-0155-2
doi: 10.1007/s00264-006-0155-2
pubmed: 16761152
Meek RM, Michos J, Grigoris P, Hamblen DL (2002) Mid-term results and migration behaviour of a ti-alloy cemented stem. Int Orthop 26:356–360. https://doi.org/10.1007/s00264-002-0386-9
doi: 10.1007/s00264-002-0386-9
pubmed: 12466868
pmcid: 3620970
Krismer M, Stöckl B, Fischer M, Bauer R, Mayrhofer P, Ogon M (1996) Early migration predicts late aseptic failure of hip sockets. J Bone JtSurg Br 78:422–426
doi: 10.1302/0301-620X.78B3.0780422
Mjöberg B (1991) Fixation and loosening of hip prostheses. A review. Acta OrthopScand 62:500–508. https://doi.org/10.3109/17453679108996658
doi: 10.3109/17453679108996658
Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225–1236. https://doi.org/10.1016/0021-9290(94)00177-6
doi: 10.1016/0021-9290(94)00177-6
pubmed: 8550641
Abrahams JM, Callary SA, Jang SW, Hewitt J, Howie DW, Solomon LB (2020) Accuracy of EBRA-cup measurements after reconstruction of severe acetabular defects at revision THR. J Orthop Res. https://doi.org/10.1002/jor.24623
doi: 10.1002/jor.24623
pubmed: 32039492
Biedermann R, Krismer M, Stöckl B, Mayrhofer P, Ornstein E, Franzén H (1999) Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse-femoral component analysis. J Bone JtSurg Br 81:266–272. https://doi.org/10.1302/0301-620x.81b2.8842
doi: 10.1302/0301-620x.81b2.8842
Ochsner PE (1998) Measurement of the acetabular migration by using standard A.P. radiographs (EBRA): technique, results and practical applications in clinical works. J Bone JtSurg Br 80:33
Registry AOANJR (2020) Annual Report 2019. https://aoanjrr.sahmri.com/documents/10180/668596/Hip%2C+Knee+%26+Shoulder+Arthroplasty/c287d2a3-22df-a3bb-37a2-91e6c00bfcf0 . Accessed 10 May 2020
DePuy Synthes (2018) Pinnacle hip solutions. https://www.corailpinnacle.net/sites/default/files/2018-10/DSEMJRC05181044%20PINNACLE%20Surgical%20Technique.pdf . Accessed 10 May 2020.
DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res (121):20–32
Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R (2008) Migration of the Duraloc cup after 5 years. Int Orthop 32:791–794. https://doi.org/10.1007/s00264-007-0405-y
doi: 10.1007/s00264-007-0405-y
pubmed: 17609953
Takatori Y, Ninomiya S, Umeyama T, Yamamoto M, Moro T, Nakamura K (2002) Bipolar revision arthroplasty for failed threaded acetabular components: radiographic evaluation of cup migration. J Orthop Sci 7:467–471. https://doi.org/10.1007/s007760200081
doi: 10.1007/s007760200081
pubmed: 12181661
Ilchmann T, Franzén H, Mjöberg B, Wingstrand H (1992) Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 7:121–127. https://doi.org/10.1016/0883-5403(92)90004-a
doi: 10.1016/0883-5403(92)90004-a
pubmed: 1613517
Phillips NJ, Stockley I, Wilkinson JM (2002) Direct plain radiographic methods versus EBRA-digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 17:917–925. https://doi.org/10.1054/arth.2002.34529
doi: 10.1054/arth.2002.34529
pubmed: 12375253
Stihsen C, Rath C, Radl R, Saalabian AA, Materna W, Rehak P, Windhager R (2013) Early migration characteristics of a 180° porous-coated cup with 1-mm press fit. Arch Orthop Trauma Surg 133:707–712. https://doi.org/10.1007/s00402-013-1713-x
doi: 10.1007/s00402-013-1713-x
pubmed: 23475053
Stöckl B, Sandow M, Krismer M, Biedermann R, Wimmer C, Frischhut B (1999) Migration of the Duraloc cup at two years. J Bone JtSurg Br 81:51–53. https://doi.org/10.1302/0301-620x.81b1.9036
doi: 10.1302/0301-620x.81b1.9036
Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R (2005) Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop 29:14–17. https://doi.org/10.1007/s00264-004-0600-z
doi: 10.1007/s00264-004-0600-z
pubmed: 15490162
Krismer M, Biedermann R, Stöckl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone JtSurg Br 81:273–280. https://doi.org/10.1302/0301-620x.81b2.8840
doi: 10.1302/0301-620x.81b2.8840