Quality of Colonoscopy Is Associated With Adenoma Detection and Postcolonoscopy Colorectal Cancer Prevention in Lynch Syndrome.
Colonoscopy
Colonoscopy Quality
Colorectal Neoplasms
HNPCC
Hereditary Colorectal Cancer
Hereditary Nonpolyposis Colorectal Cancer
Lynch Syndrome
Journal
Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association
ISSN: 1542-7714
Titre abrégé: Clin Gastroenterol Hepatol
Pays: United States
ID NLM: 101160775
Informations de publication
Date de publication:
03 2022
03 2022
Historique:
received:
07
07
2020
revised:
28
10
2020
accepted:
01
11
2020
pubmed:
7
11
2020
medline:
17
3
2022
entrez:
6
11
2020
Statut:
ppublish
Résumé
Colonoscopy reduces colorectal cancer (CRC) incidence and mortality in Lynch syndrome (LS) carriers. However, a high incidence of postcolonoscopy CRC (PCCRC) has been reported. Colonoscopy is highly dependent on endoscopist skill and is subject to quality variability. We aimed to evaluate the impact of key colonoscopy quality indicators on adenoma detection and prevention of PCCRC in LS. We conducted a multicenter study focused on LS carriers without previous CRC undergoing colonoscopy surveillance (n = 893). Incident colorectal neoplasia during surveillance and quality indicators of all colonoscopies were analyzed. We performed an emulated target trial comparing the results from the first and second surveillance colonoscopies to assess the effect of colonoscopy quality indicators on adenoma detection and PCCRC incidence. Risk analyses were conducted using a multivariable logistic regression model. The 10-year cumulative incidence of adenoma and PCCRC was 60.6% (95% CI, 55.5%-65.2%) and 7.9% (95% CI, 5.2%-10.6%), respectively. Adequate bowel preparation (odds ratio [OR], 2.07; 95% CI, 1.06-4.3), complete colonoscopies (20% vs 0%; P = .01), and pan-chromoendoscopy use (OR, 2.14; 95% CI, 1.15-3.95) were associated with significant improvement in adenoma detection. PCCRC risk was significantly lower when colonoscopies were performed during a time interval of less than every 3 years (OR, 0.35; 95% CI, 0.14-0.97). We observed a consistent but not significant reduction in PCCRC risk for a previous complete examination (OR, 0.16; 95% CI, 0.03-1.28), adequate bowel preparation (OR, 0.64; 95% CI, 0.17-3.24), or previous use of high-definition colonoscopy (OR, 0.37; 95% CI, 0.02-2.33). Complete colonoscopies with adequate bowel preparation and chromoendoscopy use are associated with improved adenoma detection, while surveillance intervals of less than 3 years are associated with a reduction of PCCRC incidence. In LS, high-quality colonoscopy surveillance is of utmost importance for CRC prevention.
Sections du résumé
BACKGROUND & AIMS
Colonoscopy reduces colorectal cancer (CRC) incidence and mortality in Lynch syndrome (LS) carriers. However, a high incidence of postcolonoscopy CRC (PCCRC) has been reported. Colonoscopy is highly dependent on endoscopist skill and is subject to quality variability. We aimed to evaluate the impact of key colonoscopy quality indicators on adenoma detection and prevention of PCCRC in LS.
METHODS
We conducted a multicenter study focused on LS carriers without previous CRC undergoing colonoscopy surveillance (n = 893). Incident colorectal neoplasia during surveillance and quality indicators of all colonoscopies were analyzed. We performed an emulated target trial comparing the results from the first and second surveillance colonoscopies to assess the effect of colonoscopy quality indicators on adenoma detection and PCCRC incidence. Risk analyses were conducted using a multivariable logistic regression model.
RESULTS
The 10-year cumulative incidence of adenoma and PCCRC was 60.6% (95% CI, 55.5%-65.2%) and 7.9% (95% CI, 5.2%-10.6%), respectively. Adequate bowel preparation (odds ratio [OR], 2.07; 95% CI, 1.06-4.3), complete colonoscopies (20% vs 0%; P = .01), and pan-chromoendoscopy use (OR, 2.14; 95% CI, 1.15-3.95) were associated with significant improvement in adenoma detection. PCCRC risk was significantly lower when colonoscopies were performed during a time interval of less than every 3 years (OR, 0.35; 95% CI, 0.14-0.97). We observed a consistent but not significant reduction in PCCRC risk for a previous complete examination (OR, 0.16; 95% CI, 0.03-1.28), adequate bowel preparation (OR, 0.64; 95% CI, 0.17-3.24), or previous use of high-definition colonoscopy (OR, 0.37; 95% CI, 0.02-2.33).
CONCLUSIONS
Complete colonoscopies with adequate bowel preparation and chromoendoscopy use are associated with improved adenoma detection, while surveillance intervals of less than 3 years are associated with a reduction of PCCRC incidence. In LS, high-quality colonoscopy surveillance is of utmost importance for CRC prevention.
Identifiants
pubmed: 33157315
pii: S1542-3565(20)31514-7
doi: 10.1016/j.cgh.2020.11.002
pii:
doi:
Types de publication
Journal Article
Multicenter Study
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
611-621.e9Informations de copyright
Copyright © 2022 AGA Institute. Published by Elsevier Inc. All rights reserved.