Résumé
Retrospective case series. The purpose of this study was to assess the diagnostic yield of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) for surgical site infection (SSI) after spine surgery. Diagnosis of SSI in the spine based on F-18 FDG PET/CT requires experienced nuclear medical physicians for a detailed analysis of F-18 FDG distribution pattern. It has also been reported that increases in the maximal standardized uptake values of F-18 FDG (SUVmax) closely correlated with SSI, suggesting potential of more objective and quantitative diagnosis. We assessed the diagnostic yield of F-18 FDG PET/CT (pattern-based diagnosis by nuclear medical physicians and SUVmax-based diagnosis) for SSI in 52 subjects who underwent spine surgery. The 52 subjects included 11 nonimplant and 41 implant cases. F-18 FDG PET/CT was performed in 33 and 19 cases in early (≤12 weeks after the surgery) and late (>12 weeks) phases, respectively. The final diagnosis of SSI was based on the results of pathogen identification, plain radiography, and CT and/or magnetic resonance imaging or response to antibiotics and/or reoperation. SUVmax-based diagnosis was performed with a cut off value of 5.0 as determined by receiver operating characteristic analysis. Both pattern-based and SUVmax-based diagnoses demonstrated excellent diagnostic yields with high sensitivity (97% and 90%), specificity (100% and 100%), and accuracy (98% and 94%). High diagnostic yields (accuracy of ≥90%) were consistently observed irrespective of presence or absence of implantation or interval between surgery and F-18 FDG PET/CT. F-18 FDG PET/CT can be the procedure of choice for investigation of SSI in the spine when other imaging fails to provide a definitive diagnosis.Level of Evidence: 4.
Sections du résumé
STUDY DESIGN
METHODS
Retrospective case series.
OBJECTIVE
OBJECTIVE
The purpose of this study was to assess the diagnostic yield of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) for surgical site infection (SSI) after spine surgery.
SUMMARY OF BACKGROUND DATA
BACKGROUND
Diagnosis of SSI in the spine based on F-18 FDG PET/CT requires experienced nuclear medical physicians for a detailed analysis of F-18 FDG distribution pattern. It has also been reported that increases in the maximal standardized uptake values of F-18 FDG (SUVmax) closely correlated with SSI, suggesting potential of more objective and quantitative diagnosis.
METHODS
METHODS
We assessed the diagnostic yield of F-18 FDG PET/CT (pattern-based diagnosis by nuclear medical physicians and SUVmax-based diagnosis) for SSI in 52 subjects who underwent spine surgery. The 52 subjects included 11 nonimplant and 41 implant cases. F-18 FDG PET/CT was performed in 33 and 19 cases in early (≤12 weeks after the surgery) and late (>12 weeks) phases, respectively. The final diagnosis of SSI was based on the results of pathogen identification, plain radiography, and CT and/or magnetic resonance imaging or response to antibiotics and/or reoperation.
RESULTS
RESULTS
SUVmax-based diagnosis was performed with a cut off value of 5.0 as determined by receiver operating characteristic analysis. Both pattern-based and SUVmax-based diagnoses demonstrated excellent diagnostic yields with high sensitivity (97% and 90%), specificity (100% and 100%), and accuracy (98% and 94%). High diagnostic yields (accuracy of ≥90%) were consistently observed irrespective of presence or absence of implantation or interval between surgery and F-18 FDG PET/CT.
CONCLUSION
CONCLUSIONS
F-18 FDG PET/CT can be the procedure of choice for investigation of SSI in the spine when other imaging fails to provide a definitive diagnosis.Level of Evidence: 4.
Identifiants
pubmed: 33290366
pii: 00007632-202105150-00014
doi: 10.1097/BRS.0000000000003847
doi:
Substances chimiques
Radiopharmaceuticals
0
Fluorodeoxyglucose F18
0Z5B2CJX4D
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
E602-E610Informations de copyright
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
Références
Chahoud J, Kanafani Z, Kanj SS. Surgical site infections following spine surgery: eliminating the controversies in the diagnosis. Front Med (Lausanne) 2014; 1:7.
Kawabata A, Sakai K, Sato H, et al. Methicillin-resistant staphylococcus aureus nasal swab and suction drain tip cultures in 4573 spinal surgeries: efficacy in management of surgical site infections. Spine (Phila Pa 1976) 2018; 43:E430–E435.
Lemans JVC, Wijdicks SPJ, Boot W, et al. Intrawound treatment for prevention of surgical site infections in instrumented spinal surgery: a systematic comparative effectiveness review and meta-analysis. Global Spine J 2019; 9:219–230.
Jo JE, Miller AO, Cohn MR, et al. Evaluating the diagnostic yield of computed tomography-guided aspirations in suspected post-operative spine infections. HSS J 2016; 12:119–124.
Epstein NE. Preoperative measures to prevent/minimize risk of surgical site infection in spinal surgery. Surg Neurol Int 2018; 9:251.
Meredith DS, Kepler CK, Huang RC, et al. Postoperative infections of the lumbar spine: presentation and management. Int orthop 2012; 36:439–444.
Kouijzer IJE, Scheper H, de Rooy JWJ, et al. The diagnostic value of 18F-FDG-PET/CT and MRI in suspected vertebral osteomyelitis - a prospective study. Eur J Nucl Med Mol Imaging 2018; 45:798–805.
Smids C, Kouijzer IJ, Vos FJ, et al. A comparison of the diagnostic value of MRI and 18F-FDG-PET/CT in suspected spondylodiscitis. Infection 2017; 45:41–49.
Kloiber R, Koslowsky IL, Tchajkov I, et al. Pattern-based interpretation criteria for 18F-fludeoxyglucose positron emission tomography/computed tomography in the assessment of pyogenic spine infection. Can Assoc Radiol J 2018; 69:397–408.
Gemmel F, Rijk PC, Collins JM, et al. Expanding role of 18F-fluoro-D-deoxyglucose PET and PET/CT in spinal infections. Eur Spine J 2010; 19:540–551.
Ohtori S, Suzuki M, Koshi T, et al. 18F-fluorodeoxyglucose-PET for patients with suspected spondylitis showing Modic change. Spine (Phila Pa 1976) 2010; 35:E1599–E1603.
De Winter F, Gemmel F, Van De Wiele C, et al. 18-Fluorine fluorodeoxyglucose positron emission tomography for the diagnosis of infection in the postoperative spine. Spine (Phila Pa 1976) 2003; 28:1314–1319.
De Winter F, van de Wiele C, Vogelaers D, et al. Fluorine-18 fluorodeoxyglucose-position emission tomography: a highly accurate imaging modality for the diagnosis of chronic musculoskeletal infections. J Bone Joint Surg Am 2001; 83:651–660.
Wenter V, Muller JP, Albert NL, et al. The diagnostic value of [(18)F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection. Eur J Nucl Med Mol Imaging 2016; 43:749–761.
Yu GJ, Koslowsky IL, Riccio SA, et al. Diagnostic challenges in pyogenic spinal infection: an expanded role for FDG-PET/CT. Eur J Clin Microbiol Infect Dis 2018; 37:501–509.
Fuster D, Tomas X, Mayoral M, et al. Prospective comparison of whole-body (18)F-FDG PET/CT and MRI of the spine in the diagnosis of haematogenous spondylodiscitis. Eur J Nucl Med Mol Imaging 2015; 42:264–271.
Wang Y, Cheung JP, Cheung KM. Use of PET/CT in the early diagnosis of implant related wound infection and avoidance of wound debridement. Eur Spine J 2016; 25: (suppl 1): 38–43.
Brown TL, Spencer HJ, Beenken KE, et al. Evaluation of dynamic [18F]-FDG-PET imaging for the detection of acute post-surgical bone infection. PLoS One 2012; 7:e41863.
Bouter C, Meller B, Sahlmann CO, et al. 68Ga-Pentixafor PET/CT imaging of chemokine receptor CXCR4 in chronic infection of the bone: first insights. J Nucl Med 2018; 59:320–326.
Inanami H, Oshima Y, Iwahori T, et al. Role of 18F-fluoro-D-deoxyglucose PET/CT in diagnosing surgical site infection after spine surgery with instrumentation. Spine (Phila Pa 1976) 2015; 40:109–113.
Silber JS, Anderson DG, Vaccaro AR, et al. Management of postprocedural discitis. Spine J 2002; 2:279–287.
Jevtic V. Vertebral infection. Eur Radiol 2004; 14: (suppl 3): E43–52.
Vaccaro AR, Shah SH, Schweitzer ME, et al. MRI description of vertebral osteomyelitis, neoplasm, and compression fracture. Orthopedics 1999; 22:67–73.
Djukic S, Genant HK, Helms CA, et al. Magnetic resonance imaging of the postoperative lumbar spine. Radiol Clin North Am 1990; 28:341–360.
Djukic S, Lang P, Morris J, et al. The postoperative spine. Magnetic resonance imaging. Orthop Clin North Am 1990; 21:603–624.
Mangram AJ, Horan TC, Pearson ML, et al. Guideline for prevention of suigical site infection, 1999. (Available at: https://stacks.cdc.gov/view/cdc/7160 ).
Moskowitz CS, Pepe MS. Comparing the predictive values of diagnostic tests: sample size and analysis for paired study designs. Clin Trials 2006; 3:272–279.
Tokuda Y, Oshima H, Araki Y, et al. Detection of thoracic aorta prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography. Eur J Cardiothorac Surg 2013; 43:11837–11847.
Mitra A, Pencharz D, Davis M, et al. Determining the diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in detecting prosthetic aortic graft infection. Ann Vasc Surg 2018; 1–8.
Matsuo Y, Ogawa T, Yamamoto M, et al. Evaluation of peri-implant bone metabolism under immediate loading using high-resolution Na18F-PET. Clin Oral Investig 2017; 21:2029–2037.
Yamamoto M, Ogawa T, Yokoyama M, et al. Na18F accumulates on the compressive side of peri-implant bone under immediate loading. Odontology 2018; 106:232–237.
Nanni C, Boriani L, Salvadori C, et al. FDG PET/CT is useful for the interim evaluation of response to therapy in patients affected by haematogenous spondylodiscitis. Eur J Nucl Med Mol Imaging 2012; 39:1538–1544.