Radiation exposure in computed tomography (CT) is automatically modulated by automatic exposure control (AEC) mainly based on scout images. To simulate the whole-body positron emission tomography/CT, CT images of a phantom were obtained using the posteroanterior scout image alone (PA scout) or the posteroanterior and lateral images (PA + Lat scout). Old and new versions of the AEC software were compared. Using the old version of the software and the PA scout, a markedly high dose at the top of the head was observed, which varied depending on the position of the phantom. This issue was resolved in the new version of the software. Radiation dose in the shoulder region was much higher using the PA scout than using the PA + Lat scout, even with the new version of the software. AEC may cause unreasonably high radiation exposure locally, and the appropriateness of the dose modulation pattern should be examined at each facility.

Identifiants

pubmed: 33302289
pii: 6030106
doi: 10.1093/rpd/ncaa197
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

69-74

Informations de copyright

© The Author(s) 2020. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Auteurs

Yusuke Inoue (Y)

Department of Diagnostic Radiology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Mizuho Adachi (M)

Department of Diagnostic Radiology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Hirokazu Shimizu (H)

Department of Diagnostic Radiology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Kazunori Nagahara (K)

Department of Radiology, Kitasato University Hospital, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Hiroyasu Itoh (H)

Department of Radiology, Kitasato University Hospital, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Makoto Takano (M)

Department of Radiology, Kitasato University Hospital, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Koji Jinguji (K)

Department of Radiology, Kitasato University Hospital, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, Japan.

Articles similaires

Humans Magnetic Resonance Imaging Phantoms, Imaging Infant, Newborn Signal-To-Noise Ratio
Humans Shoulder Fractures Tomography, X-Ray Computed Neural Networks, Computer Female
Humans Arthroplasty, Replacement, Knee Osteoarthritis, Knee Awards and Prizes Biomechanical Phenomena
Humans Range of Motion, Articular Arthroplasty, Replacement, Shoulder Posture Female

Classifications MeSH