Restorative CAD/CAM materials in dentistry: analysis of their fluorescence properties and the applicability of the fluorescence-aided identification technique (FIT).

CAD/CAM technology Ceramics Dental materials Fluorescence Fluorescence-aided identification technique Resin-based composites

Journal

Clinical oral investigations
ISSN: 1436-3771
Titre abrégé: Clin Oral Investig
Pays: Germany
ID NLM: 9707115

Informations de publication

Date de publication:
Jul 2021
Historique:
received: 22 06 2020
accepted: 30 12 2020
pubmed: 16 1 2021
medline: 28 7 2021
entrez: 15 1 2021
Statut: ppublish

Résumé

This study investigated the fluorescence properties of the most commonly used fluorescent CAD/CAM materials for monolithic dental restorations and their suitability to perform the fluorescence-aided identification technique (FIT). A total of 175 different color shades (n = 1) from 13 CAD/CAM material brands were analyzed with a monochromator-based microplate reader. Additionally, dentin, enamel, and combined dentin-enamel specimens (respectively, n = 11) were analyzed for comparison purposes. The maximum fluorescence intensity, the corresponding excitation and emission wavelength, and the total fluorescence for the wavelength spectrum λ All assessed CAD/CAM ceramics showed virtually no total fluorescence for the wavelength spectrum λ Apart from the mentioned exceptions, all CAD/CAM materials assessed could be suitable for the FIT, either because they are more fluorescent than hard tooth substances or because they do not fluoresce at all at the respective wavelength of λ This study provides insight into the not yet well-known fluorescent properties of dental CAD/CAM materials. This knowledge is not only necessary to reproduce the fluorescence properties of natural teeth but also for the applicability of diagnostic fluorescence inducing techniques.

Identifiants

pubmed: 33447911
doi: 10.1007/s00784-020-03772-w
pii: 10.1007/s00784-020-03772-w
doi:

Substances chimiques

Composite Resins 0
Dental Materials 0
Dental Porcelain 12001-21-7

Types de publication

Journal Article

Langues

eng

Pagination

4579-4589

Informations de copyright

© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.

Références

Rekow D (1987) Computer-aided design and manufacturing in dentistry: a review of the state of the art. J Prosthet Dent 58(4):512–516. https://doi.org/10.1016/0022-3913(87)90285-x
doi: 10.1016/0022-3913(87)90285-x pubmed: 3312586
Moore GE (1965) Cramming more components onto integrated circuits. Electronics 38(8):114–117
Zaruba M, Mehl A (2017) Chairside systems: a current review. Int J Comput Dent 20(2):123–149
pubmed: 28630955
Chochlidakis KM, Papaspyridakos P, Geminiani A, Chen CJ, Feng IJ, Ercoli C (2016) Digital versus conventional impressions for fixed prosthodontics: a systematic review and meta-analysis. J Prosthet Dent 116(2):184–190.e112. https://doi.org/10.1016/j.prosdent.2015.12.017
doi: 10.1016/j.prosdent.2015.12.017 pubmed: 26946916
Gallardo YR, Bohner L, Tortamano P, Pigozzo MN, Lagana DC, Sesma N (2018) Patient outcomes and procedure working time for digital versus conventional impressions: a systematic review. J Prosthet Dent 119(2):214–219. https://doi.org/10.1016/j.prosdent.2017.07.007
doi: 10.1016/j.prosdent.2017.07.007 pubmed: 28967407
Barenghi L, Barenghi A, Cadeo C, Di Blasio A (2019) Innovation by computer-aided design/computer-aided manufacturing technology: a look at infection prevention in dental settings. Biomed Res Int 2019:6092018–6092015. https://doi.org/10.1155/2019/6092018
doi: 10.1155/2019/6092018 pubmed: 31467901 pmcid: 6699473
Bajraktarova-Valjakova E, Korunoska-Stevkovska V, Kapusevska B, Gigovski N, Bajraktarova-Misevska C, Grozdanov A (2018) Contemporary dental ceramic materials, a review: chemical composition, physical and mechanical properties, indications for use. Open Access Maced J Med Sci 6(9):1742–1755. https://doi.org/10.3889/oamjms.2018.378
doi: 10.3889/oamjms.2018.378 pubmed: 30338002 pmcid: 6182519
Blatz MB, Conejo J (2019) The current state of chairside digital dentistry and materials. Dent Clin N Am 63(2):175–197. https://doi.org/10.1016/j.cden.2018.11.002
doi: 10.1016/j.cden.2018.11.002 pubmed: 30825985
Spitznagel FA, Boldt J, Gierthmuehlen PC (2018) CAD/CAM ceramic restorative materials for natural teeth. J Dent Res 97(10):1082–1091. https://doi.org/10.1177/0022034518779759
doi: 10.1177/0022034518779759 pubmed: 29906206
Krejci I, Lieber CM, Lutz F (1995) Time required to remove totally bonded tooth-colored posterior restorations and related tooth substance loss. Dent Mater 11(1):34–40. https://doi.org/10.1016/0109-5641(95)80006-9
doi: 10.1016/0109-5641(95)80006-9 pubmed: 7498606
Szep S, Baum C, Alamouti C, Schmidt D, Gerhardt T, Heidemann D (2002) Removal of amalgam, glass-ionomer cement and compomer restorations: changes in cavity dimensions and duration of the procedure. Oper Dent 27(6):613–620
pubmed: 12413228
Dörter C, Yildiz E, Erdemir U (2003) Effect of operators’ skills on increase in cavity volume of restorations. Quintessence Int 34(1):27–30
pubmed: 12674355
Hunter AR, Treasure ET, Hunter AJ (1995) Increases in cavity volume associated with the removal of class 2 amalgam and composite restorations. Oper Dent 20(1):2–6
pubmed: 8700763
Carson DO, Orihara Y, Sorbie JL, Pounder DJ (1997) Detection of white restorative dental materials using an alternative light source. Forensic Sci Int 88(2):163–168
doi: 10.1016/S0379-0738(97)00115-1
Clark DH, Ruddick RF (1985) Post mortem detection of tooth coloured dental restorations by ultra violet radiation. Acta Med Leg Soc 35(1):278–284
Pretty IA, Smith PW, Edgar WM, Higham SM (2002) The use of quantitative light-induced fluorescence (QLF) to identify composite restorations in forensic examinations. J Forensic Sci 47(4):831–836
doi: 10.1520/JFS15468J
Bush MA, Hermanson AS, Yetto RJ, Wieczkowski G Jr (2010) The use of ultraviolet LED illumination for composite resin removal: an in vitro study. Gen Dent 58(5):e214–e218
pubmed: 20829156
Hermanson AS, Bush MA, Miller RG, Bush PJ (2008) Ultraviolet illumination as an adjunctive aid in dental inspection. J Forensic Sci 53(2):408–411. https://doi.org/10.1111/j.1556-4029.2008.00657.x
doi: 10.1111/j.1556-4029.2008.00657.x pubmed: 18366574
Lim YK, Lee YK (2007) Fluorescent emission of varied shades of resin composites. Dent Mater 23(10):1262–1268. https://doi.org/10.1016/j.dental.2006.11.022
doi: 10.1016/j.dental.2006.11.022 pubmed: 17196645
Tani K, Watari F, Uo M, Morita M (2003) Discrimination between composite resin and teeth using fluorescence properties. Dent Mater J 22(4):569–580
doi: 10.4012/dmj.22.569
Meller C, Klein C (2012) Fluorescence properties of commercial composite resin restorative materials in dentistry. Dent Mater J 31(6):916–923
doi: 10.4012/dmj.2012-079
Meller C, Klein C (2015) Fluorescence of composite resins: a comparison among properties of commercial shades. Dent Mater J 34(6):754–765. https://doi.org/10.4012/dmj.2014-219
doi: 10.4012/dmj.2014-219 pubmed: 26632224
Kiran R, Chapman J, Tennant M, Forrest A, Walsh LJ (2019) Detection of tooth-colored restorative materials for forensic purposes based on their optical properties: an in vitro comparative study. J Forensic Sci 64(1):254–259. https://doi.org/10.1111/1556-4029.13851
doi: 10.1111/1556-4029.13851 pubmed: 29989157
Meller C, Connert T, Löst C, ElAyouti A (2017) Reliability of a fluorescence-aided identification technique (FIT) for detecting tooth-colored restorations: an ex vivo comparative study. Clin Oral Investig 21(1):347–355. https://doi.org/10.1007/s00784-016-1797-0
doi: 10.1007/s00784-016-1797-0 pubmed: 27005811
Salomao FM, Rocha RS, Franco LM, Sundfeld RH, Bresciani E, Fagundes TC (2019) Auxiliary UV light devices for removal of fluorescent resin residues after bracket debonding. J Esthet Restor Dent 31(1):58–63. https://doi.org/10.1111/jerd.12412
doi: 10.1111/jerd.12412 pubmed: 30194909
Schott TC, Meller C (2018) A new fluorescence-aided identification technique (FIT) for optimal removal of resin-based bracket bonding remnants after orthodontic debracketing. Quintessence Int 49(10):809–813. https://doi.org/10.3290/j.qi.a41171
doi: 10.3290/j.qi.a41171 pubmed: 30264058
Stadler O, Dettwiler C, Meller C, Dalstra M, Verna C, Connert T (2019) Evaluation of a fluorescence-aided identification technique (FIT) to assist clean-up after orthodontic bracket debonding. Angle Orthod 89(6):876–882. https://doi.org/10.2319/100318714.1
doi: 10.2319/100318714.1 pubmed: 31206307 pmcid: 8109158
Saccardin F, Ortiz V, Dettwiler C, Connert T, Filippi A (2019) Removal of composite-bonded trauma splints using the fluorescence-aided identification technique (FIT). Quintessence Int 50(6):456–460
pubmed: 31111124
Dettwiler C, Meller C, Eggmann F, Saccardin F, Kuhl S, Filippi A, Krastl G, Weiger R, Connert T (2018) Evaluation of a fluorescence-aided identification technique (FIT) for removal of composite bonded trauma splints. Dent Traumatol 34(5):353–359. https://doi.org/10.1111/edt.12425
doi: 10.1111/edt.12425 pubmed: 29983006
Kiran R, Chapman J, Tennant M, Forrest A, Walsh LJ (2019) Fluorescence-aided selective removal of resin-based composite restorative materials: an in vitro comparative study. J Esthet Restor Dent 32:310–316. https://doi.org/10.1111/jerd.12536
doi: 10.1111/jerd.12536 pubmed: 31618521
Dettwiler C, Eggmann F, Matthisson L, Meller C, Weiger R, Connert T (2019) Fluorescence-aided composite removal in directly restored permanent posterior teeth. Oper Dent 45:62–70. https://doi.org/10.2341/19-032-l
doi: 10.2341/19-032-l pubmed: 31373886
Klein C, Babai A, von Ohle C, Herz M, Wolff D, Meller C (2019) Minimally invasive removal of tooth-colored restorations: evaluation of a novel handpiece using the fluorescence-aided identification technique (FIT). Clin Oral Investig 24:2735–2743. https://doi.org/10.1007/s00784-019-03135-0
doi: 10.1007/s00784-019-03135-0 pubmed: 31712984
Stockman A, Jägle H, Pirzer M, Sharpe LT (2008) The dependence of luminous efficiency on chromatic adaptation. J Vis 8(16):1-1-26. https://doi.org/10.1167/8.16.1
doi: 10.1167/8.16.1 pubmed: 19146268
Sharpe LT, Stockman A, Jagla W, Jägle H (2005) A luminous efficiency function, V*(λ), for daylight adaptation. J Vis 5(11):948–968. https://doi.org/10.1167/5.11.3
doi: 10.1167/5.11.3 pubmed: 16441195
Stockman A, Sharpe LT (2000) The spectral sensitivities of the middle- and long-wavelength-sensitive cones derived from measurements in observers of known genotype. Vis Res 40(13):1711–1737. https://doi.org/10.1016/S0042-6989(00)00021-3
doi: 10.1016/S0042-6989(00)00021-3 pubmed: 10814758
Mazur-Koczorowska A, Sikorska E, Krawczyk A, Khmelinskii I, Sikorski M, Koczorowski R, Stopa J (2008) Luminescence of selected dental composites in vitro. Dent Mater 24(10):1329–1335. https://doi.org/10.1016/j.dental.2008.02.014
doi: 10.1016/j.dental.2008.02.014 pubmed: 18405961
Gawriołek M, Sikorska E, Ferreira LFV, Costa AI, Khmelinskii I, Krawczyk A, Sikorski M, Koczorowski PR (2012) Color and luminescence stability of selected dental materials in vitro. J Prosthodont 21(2):112–122. https://doi.org/10.1111/j.1532-849X.2011.00808.x
doi: 10.1111/j.1532-849X.2011.00808.x pubmed: 22380646
Antonov M, Lenhardt L, Manojlovic D, Milicevic B, Zekovic I, Dramicanin MD (2016) Changes of color and fluorescence of resin composites immersed in beer. J Esthet Restor Dentist 28(5):330–338. https://doi.org/10.1111/jerd.12232
doi: 10.1111/jerd.12232
Laurila UR, Mancewicz SA, Forziati AF (1960) Isolation and partial fractiontion of fluorescence material from human teeth. J Dent Res 39(4):714 Abstr. No. 175. https://doi.org/10.1177/00220345600390040301
doi: 10.1177/00220345600390040301
Armstrong WG (1963) Fluorescence characteristics of sound and carious human dentine preparations. Arch Oral Biol 8(2):79–90. https://doi.org/10.1016/0003-9969(63)90045-1
doi: 10.1016/0003-9969(63)90045-1
Spitzer D, Bosch JJ (1976) The total luminescence of bovine and human dental enamel. Calcif Tissue Res 2:201–208
doi: 10.1007/BF02546408
Monsénego G, Burdairon G, Porte C, Naud C (1990) Étude de la fluorescence de la porcelaine dentaire: Matériel et méthodes. Cah Prothese 70:79–85
Monsénego G, Burdairon G, Clerjaud B (1993) Fluorescence of dental porcelain. J Prosthet Dent 69(1):106–113
doi: 10.1016/0022-3913(93)90249-N
Rattle CN, Bush MA (2009) Fluorescence and structural degradation in composite resins as a function of temperature. J Forensic Sci 54(2):433–438. https://doi.org/10.1111/j.1556-4029.2008.00968.x
doi: 10.1111/j.1556-4029.2008.00968.x pubmed: 19187454
Park MY, Lee YK, Lim BS (2007) Influence of fluorescent whitening agent on the fluorescent emission of resin composites. Dent Mater 23(6):731–735. https://doi.org/10.1016/j.dental.2006.06.028
doi: 10.1016/j.dental.2006.06.028 pubmed: 16911821
Baran GR, O'Brien WJ, Tien TY (1977) Colored emission of rare earth ions in a potassium feldspar glass. J Dent Res 56(11):1323–1329. https://doi.org/10.1177/00220345770560110401
doi: 10.1177/00220345770560110401 pubmed: 274451
Peplinski DR, Wozniak WT, Moser JB (1980) Spectral studies of new luminophors for dental porcelain. J Dent Res 59(9):1501–1506. https://doi.org/10.1177/00220345800590090801
doi: 10.1177/00220345800590090801 pubmed: 6931128
Meller C, Schott T (2018) Integrity testing of a smooth surface resin sealant around orthodontic brackets using a new fluorescence-aided identification technique (FIT). Angle Orthod 88(6):765–770. https://doi.org/10.2319/110217-748.1
doi: 10.2319/110217-748.1 pubmed: 30004785 pmcid: 8174085
Lennon AM (2003) Fluorescence-aided caries excavation (FACE) compared to conventional method. Oper Dent 28(4):341–345
pubmed: 12877417
Walsh LJ (2018) Caries diagnosis aided by fluorescence. In: Akarslan Z (ed) Dental caries - diagnosis, prevention and management. IntechOpen Limited, London. https://doi.org/10.5772/intechopen.71994
doi: 10.5772/intechopen.71994
Judd DB (1951) Report of U.S. secretariat committee on colorimetry and artificial daylight, proceedings of the twelfth session of the CIE, Stockholm. Bureau Central de la CIE, Paris, p 11
Vos JJ (1978) Colorimetric and photometric properties of a 2° fundamental observer. Color Res Appl 3(3):125–128. https://doi.org/10.1002/col.5080030309
doi: 10.1002/col.5080030309
Güth JF, Magne P (2016) Optical integration of CAD/CAM materials. Int J Esthet Dent 11(3):394–409
pubmed: 27433552

Auteurs

Christian Klein (C)

Department of Conservative Dentistry, Periodontology and Endodontology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr. 2-8, 72076, Tübingen, Germany. Christian.Klein@med.uni-tuebingen.de.
Private practice Meller Zahngesundheit, Waiblingen, Germany. Christian.Klein@med.uni-tuebingen.de.

Matthias Krespach (M)

Department of Conservative Dentistry, Periodontology and Endodontology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr. 2-8, 72076, Tübingen, Germany.

Sebastian Spintzyk (S)

Section Medical Materials Science & Technology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Tübingen, Germany.

Diana Wolff (D)

Department of Conservative Dentistry, Periodontology and Endodontology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr. 2-8, 72076, Tübingen, Germany.

Christiane von Ohle (C)

Department of Conservative Dentistry, Periodontology and Endodontology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr. 2-8, 72076, Tübingen, Germany.

Christian Meller (C)

Department of Conservative Dentistry, Periodontology and Endodontology, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr. 2-8, 72076, Tübingen, Germany.

Articles similaires

Hemiarthroplasty in young patients.

Hazimah Mahmud, Dong Wang, Andra Topan-Rat et al.
1.00
Humans Male Hemiarthroplasty Middle Aged Aged
Silicon Dioxide Water Hot Temperature Compressive Strength X-Ray Diffraction
1.00
Sudan Archaeology Humans History, Ancient Animals
Nitriles Tensile Strength Materials Testing Gloves, Protective Product Packaging

Classifications MeSH