Development and clinical validation of a simple and fast UPLC-ESI-MS/MS method for simultaneous quantification of nine kinase inhibitors and two antiandrogen drugs in human plasma: Interest for their therapeutic drug monitoring.
Antiandrogens
Kinase inhibitors
Liquid chromatography
Mass spectrometry
Oral targeted therapies
Therapeutic drug monitoring
Journal
Journal of pharmaceutical and biomedical analysis
ISSN: 1873-264X
Titre abrégé: J Pharm Biomed Anal
Pays: England
ID NLM: 8309336
Informations de publication
Date de publication:
15 Apr 2021
15 Apr 2021
Historique:
received:
23
10
2020
revised:
04
01
2021
accepted:
09
02
2021
pubmed:
23
2
2021
medline:
22
6
2021
entrez:
22
2
2021
Statut:
ppublish
Résumé
Kinase inhibitors (KIs) and antiandrogen drugs (AAs) are oral anticancer drugs with narrow therapeutic index that exhibit high inter- and intra-individual variability. We describe here a UPLC-MS/MS method for the simultaneous quantification of nine KIs: cobimetinib, dasatinib, ibrutinib, imatinib, nilotinib, palbociclib, ruxolitinib, sorafenib and vemurafenib; two active metabolites of them: N-desmethyl imatinib, N-oxide sorafenib; and two AAs: abiraterone and enzalutamide; with short pre-treatment and run time in order to be easily used in clinical practice for their therapeutic drug monitoring (TDM) and facilitating pharmacokinetics and pharmacokinetics/pharmacodynamics studies. Plasma samples were prepared by a single-step protein precipitation. Analytes were separated on a Waters Acquity UPLC® T3 HSS C18 column by non-linear gradient elution; with subsequent detection by Xevo® TQD triple quadrupole tandem mass spectrometer in a positive ionization mode. Analysis time was 2.8 min per run, and all analytes eluted within 1.46-1.97 minutes. The analytical performance of the method in terms of specificity, sensitivity, linearity, precision, accuracy, matrix effect, extraction recovery, limit of quantification, dilution integrity and stability of analytes under different conditions met all criteria for a bioanalytical method for the quantification of drugs. The calibration curves were linear over the range of 1-500 ng/mL for abiraterone, dasatinib and ibrutinib; 5-500 ng/mL for cobimetinib and palbociclib; 10-5,000 ng/mL for imatinib, N-desmethyl imatinib, nilotinib, sorafenib, N-oxide sorafenib and ruxolitinib; 100-50,000 ng/mL for enzalutamide and 100-100,000 ng/mL for vemurafenib with coefficient of correlation above 0.995 for all analytes. This novel method was successfully applied to TDM in clinical practice.
Identifiants
pubmed: 33618135
pii: S0731-7085(21)00080-7
doi: 10.1016/j.jpba.2021.113968
pii:
doi:
Substances chimiques
Androgen Antagonists
0
Pharmaceutical Preparations
0
Protein Kinase Inhibitors
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
113968Informations de copyright
Copyright © 2021 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.