Anterior Locking Plate Osteosynthesis of Patellar Factures - Analysis of Complications and Functional Outcome.
Die winkelstabile Plattenosteosynthese der Patellafraktur – Komplikationsanalyse und funktionelles Ergebnis.
Journal
Zeitschrift fur Orthopadie und Unfallchirurgie
ISSN: 1864-6743
Titre abrégé: Z Orthop Unfall
Pays: Germany
ID NLM: 101308227
Informations de publication
Date de publication:
10 2022
10 2022
Historique:
pubmed:
20
4
2021
medline:
30
9
2022
entrez:
19
4
2021
Statut:
ppublish
Résumé
Tension band wiring is the standard procedure for patellar fractures, but is associated with a high rate of implant related complications and implant failure. Tension band wiring may fail, especially with multifragmentary and comminuted fractures. Plate fixation of complex patellar fractures seems to be superior to wiring, both clinically and biomechanically. The aim of this study was to evaluate complications after locking plate fixation in patellar fractures two years after surgery and to access the functional outcome. As part of a prospective case series, all patients who had received locking plate fixation of a patellar fracture between April 2013 and May 2018 were clinically examined two years postoperatively and potential complications were evaluated. A total of 38 patients aged 19 - 87 years were included. Complications occurred in a total of five patients (13%), including one reactive prepatellar bursitis, one chronic infection and loss of reduction due to a dislocated pole fragment in three cases. The average active range of motion of the affected knee joint two years postoperatively was 133°. The Tegner activity scale score reached 3 points, the Lysholm score 95 points and the Kujala score 95 points. With an overall relatively low complication rate and good clinical outcome, dislocated distal pole fragments are a common complication after plate fixation of patellar fractures. If preoperative diagnostic testing shows a pole fragment, a modified hook-plate can be used, with the possibility of fixing the pole fragment. Die Zuggurtungsosteosynthese als Standardverfahren von Patellafrakturen ist mit einer hohen Rate an implantatbezogenen Komplikationen und einer hohen Versagensrate assoziiert. Insbesondere mehrfragmentäre und Trümmerfrakturen können nicht adäquat versorgt werden. Die Plattenosteosynthese bei komplexen Patellafrakturen scheint biomechanisch und klinisch der Zuggurtung überlegen. Ziel der Studie war es, Komplikationen nach winkelstabiler Plattenosteosynthese bei Patellafraktur 2 Jahre postoperativ auszuwerten. Zudem wurde das funktionelle Ergebnis erfasst. Im Rahmen einer prospektiven Fallserie wurden alle Patienten, die zwischen April 2013 und Mai 2018 eine winkelstabile Plattenosteosynthese einer Patellafraktur erhalten hatten, 2 Jahre postoperativ klinisch untersucht sowie potenzielle Komplikationen ausgewertet. 38 Patienten im Alter von 19 – 87 Jahren konnten eingeschlossen werden. Bei insgesamt 5 Patienten (13%) kam es zu Komplikationen, darunter eine reaktive Bursitis praepatellaris, ein chronischer Infekt und 3 Repositionsverluste bei proximalem oder distalem Polausriss. Der aktive Bewegungsumfang des betroffenen Kniegelenkes lag 2 Jahre postoperativ durchschnittlich bei 133°. Der Tegner-Aktivitätsscore erreichte 3 Punkte der Lysholm-Score lag bei 95 Punkten und der Kujala-Score erreichte 95 Punkte. Bei vergleichbar niedriger Komplikationsrate und gutem funktionellen Outcome sind distale Polausrisse eine häufige Komplikation nach Plattenosteosynthese von Patellafrakturen. Wird präoperativ ein Polfragment erkannt, kann eine modifizierte Platte mit Haken zur Fixation eines Polfragmentes gewählt werden.
Sections du résumé
BACKGROUND
Tension band wiring is the standard procedure for patellar fractures, but is associated with a high rate of implant related complications and implant failure. Tension band wiring may fail, especially with multifragmentary and comminuted fractures. Plate fixation of complex patellar fractures seems to be superior to wiring, both clinically and biomechanically. The aim of this study was to evaluate complications after locking plate fixation in patellar fractures two years after surgery and to access the functional outcome.
MATERIAL AND METHODS
As part of a prospective case series, all patients who had received locking plate fixation of a patellar fracture between April 2013 and May 2018 were clinically examined two years postoperatively and potential complications were evaluated.
RESULTS
A total of 38 patients aged 19 - 87 years were included. Complications occurred in a total of five patients (13%), including one reactive prepatellar bursitis, one chronic infection and loss of reduction due to a dislocated pole fragment in three cases. The average active range of motion of the affected knee joint two years postoperatively was 133°. The Tegner activity scale score reached 3 points, the Lysholm score 95 points and the Kujala score 95 points.
CONCLUSION
With an overall relatively low complication rate and good clinical outcome, dislocated distal pole fragments are a common complication after plate fixation of patellar fractures. If preoperative diagnostic testing shows a pole fragment, a modified hook-plate can be used, with the possibility of fixing the pole fragment.
HINTERGRUND
UNASSIGNED
Die Zuggurtungsosteosynthese als Standardverfahren von Patellafrakturen ist mit einer hohen Rate an implantatbezogenen Komplikationen und einer hohen Versagensrate assoziiert. Insbesondere mehrfragmentäre und Trümmerfrakturen können nicht adäquat versorgt werden. Die Plattenosteosynthese bei komplexen Patellafrakturen scheint biomechanisch und klinisch der Zuggurtung überlegen. Ziel der Studie war es, Komplikationen nach winkelstabiler Plattenosteosynthese bei Patellafraktur 2 Jahre postoperativ auszuwerten. Zudem wurde das funktionelle Ergebnis erfasst.
MATERIAL UND METHODE
UNASSIGNED
Im Rahmen einer prospektiven Fallserie wurden alle Patienten, die zwischen April 2013 und Mai 2018 eine winkelstabile Plattenosteosynthese einer Patellafraktur erhalten hatten, 2 Jahre postoperativ klinisch untersucht sowie potenzielle Komplikationen ausgewertet.
ERGEBNISSE
UNASSIGNED
38 Patienten im Alter von 19 – 87 Jahren konnten eingeschlossen werden. Bei insgesamt 5 Patienten (13%) kam es zu Komplikationen, darunter eine reaktive Bursitis praepatellaris, ein chronischer Infekt und 3 Repositionsverluste bei proximalem oder distalem Polausriss. Der aktive Bewegungsumfang des betroffenen Kniegelenkes lag 2 Jahre postoperativ durchschnittlich bei 133°. Der Tegner-Aktivitätsscore erreichte 3 Punkte der Lysholm-Score lag bei 95 Punkten und der Kujala-Score erreichte 95 Punkte.
DISKUSSION
CONCLUSIONS
Bei vergleichbar niedriger Komplikationsrate und gutem funktionellen Outcome sind distale Polausrisse eine häufige Komplikation nach Plattenosteosynthese von Patellafrakturen. Wird präoperativ ein Polfragment erkannt, kann eine modifizierte Platte mit Haken zur Fixation eines Polfragmentes gewählt werden.
Autres résumés
Type: Publisher
(ger)
Die Zuggurtungsosteosynthese als Standardverfahren von Patellafrakturen ist mit einer hohen Rate an implantatbezogenen Komplikationen und einer hohen Versagensrate assoziiert. Insbesondere mehrfragmentäre und Trümmerfrakturen können nicht adäquat versorgt werden. Die Plattenosteosynthese bei komplexen Patellafrakturen scheint biomechanisch und klinisch der Zuggurtung überlegen. Ziel der Studie war es, Komplikationen nach winkelstabiler Plattenosteosynthese bei Patellafraktur 2 Jahre postoperativ auszuwerten. Zudem wurde das funktionelle Ergebnis erfasst.
Types de publication
Journal Article
Langues
eng
ger
Sous-ensembles de citation
IM
Pagination
549-558Informations de copyright
Thieme. All rights reserved.
Déclaration de conflit d'intérêts
The authors declare that they have no conflict of interest./Die Autorinnen/Autoren geben an, dass kein Interessenkonflikt besteht.