Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit.
capacitive coupling electrodes
dry electrodes
electronic interfaces and embedded sensor systems for biomedical application
electronics for biosignals and biopotentials
wearable healthcare electrocardiography
wearable monitoring systems
wearable sensors and devices
wireless ECG monitoring systems
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
15 Apr 2021
15 Apr 2021
Historique:
received:
24
03
2021
revised:
12
04
2021
accepted:
13
04
2021
entrez:
30
4
2021
pubmed:
1
5
2021
medline:
4
5
2021
Statut:
epublish
Résumé
The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.
Identifiants
pubmed: 33920787
pii: s21082777
doi: 10.3390/s21082777
pmc: PMC8071160
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Ministero dell'Istruzione, dell'Università e della Ricerca
ID : FLAG-ERA CONVERGENCE
Références
J Neuroeng Rehabil. 2012 Apr 20;9:21
pubmed: 22520559
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:1250-3
pubmed: 21095911
IEEE Trans Biomed Eng. 2000 Feb;47(2):155-62
pubmed: 10721622
Med Biol Eng Comput. 1990 Sep;28(5):389-97
pubmed: 2277538
Sensors (Basel). 2020 Sep 10;20(18):
pubmed: 32927651
Curr Opin Biomed Eng. 2019 Sep;11:58-67
pubmed: 32582870
Med Biol Eng Comput. 2012 Feb;50(2):135-44
pubmed: 22194020
Biomed Eng Online. 2010 Aug 19;9:39
pubmed: 20723232
Sensors (Basel). 2020 Mar 18;20(6):
pubmed: 32197444
BMC Med Inform Decis Mak. 2019 Dec 30;19(1):285
pubmed: 31888608
Sensors (Basel). 2019 Oct 10;19(20):
pubmed: 31658713
IEEE Trans Biomed Eng. 2011 May;58(5):1200-7
pubmed: 21193371
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:3818-21
pubmed: 18002830
IEEE Trans Biomed Eng. 2007 Apr;54(4):759-66
pubmed: 17405385
IEEE Trans Biomed Eng. 2015 Sep;62(9):2269-2278
pubmed: 25879836
Sensors (Basel). 2017 Oct 28;17(11):
pubmed: 29143768
Int J Med Inform. 2009 Mar;78(3):193-8
pubmed: 18760959
IEEE Trans Biomed Eng. 2007 Apr;54(4):718-25
pubmed: 17405379
Annu Rev Med. 2021 Jan 27;72:459-471
pubmed: 32886543
IEEE Rev Biomed Eng. 2010;3:106-19
pubmed: 22275204
IEEE Trans Biomed Eng. 2011 Nov;58(11):3112-20
pubmed: 21824839
IEEE Trans Inf Technol Biomed. 2011 May;15(3):416-27
pubmed: 20952340
J R Soc Med. 2016 Oct;109(10):372-380
pubmed: 27729595
Sensors (Basel). 2020 Mar 09;20(5):
pubmed: 32182907
IEEE Trans Biomed Eng. 2019 Mar;66(3):749-758
pubmed: 30004869
IEEE Trans Biomed Eng. 1983 Jan;30(1):62-6
pubmed: 6826188
IEEE Trans Biomed Eng. 2013 Aug;60(8):2142-52
pubmed: 23475330
Physiol Meas. 2000 May;21(2):271-83
pubmed: 10847194