COMPARISON OF CONVENTIONAL HAND EXAMINATION ON SIX OPTIMISED DR SYSTEMS.


Journal

Radiation protection dosimetry
ISSN: 1742-3406
Titre abrégé: Radiat Prot Dosimetry
Pays: England
ID NLM: 8109958

Informations de publication

Date de publication:
31 May 2021
Historique:
received: 06 01 2021
revised: 23 03 2021
accepted: 13 04 2021
pubmed: 11 5 2021
medline: 24 6 2021
entrez: 10 5 2021
Statut: ppublish

Résumé

The purpose of this study was to investigate the challenges in comparing digital radiography (DR) systems from different vendors for various combinations of exposure factors in posterior-anterior hand radiographs. Image quality was evaluated for a range of tube voltages and tube current-time products using a technical contrast-detail (CDRAD) phantom and an anthropomorphic hand phantom. 900 technical CDRAD images were analysed providing quality figures of merit (IQFinv) and two experienced reporting radiographers using visual grading analysis (VGA) scored 108 anthropomorphic images. This study demonstrates the differences between the DR systems included. When compensating for variations in dose, Canon showed superior results for technical image quality and Fuji for visual image quality for a standard dose point at DR hand examination (ln(DAP) 1.1, 50 kV and 2.5 mAs).

Identifiants

pubmed: 33969425
pii: 6272656
doi: 10.1093/rpd/ncab067
pmc: PMC8808537
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

27-35

Informations de copyright

© The Author(s) 2021. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Références

Acta Radiol Open. 2016 Dec 01;5(12):2058460116684884
pubmed: 28405477
Radiat Prot Dosimetry. 2005;114(1-3):45-52
pubmed: 15933080
Eur Radiol. 2018 Jul;28(7):2951-2959
pubmed: 29460076
Med Phys. 2020 Sep;47(9):3935-3944
pubmed: 32427360
Br J Radiol. 2018 Sep;91(1089):20180317
pubmed: 29906239
Radiat Prot Dosimetry. 2016 Jun;169(1-4):303-7
pubmed: 26535003
Radiography (Lond). 2019 Oct;25 Suppl 1:S14-S18
pubmed: 31481182
Dentomaxillofac Radiol. 2016;45(4):20150402
pubmed: 26891747
Radiography (Lond). 2018 May;24(2):137-141
pubmed: 29605110
Biometrics. 1977 Mar;33(1):159-74
pubmed: 843571
Ann ICRP. 2004;34(1):1-73
pubmed: 15302167
Radiography (Lond). 2020 May;26(2):e31-e37
pubmed: 32052778
Radiography (Lond). 2019 May;25(2):143-147
pubmed: 30955687
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):26-36
pubmed: 20147386
Semin Musculoskelet Radiol. 2012 Nov;16(5):401-9
pubmed: 23212875
J Neurosurg Sci. 2017 Dec;61(6):597-602
pubmed: 28984431
Phys Med Biol. 2011 Feb 21;56(4):979-99
pubmed: 21248386
J Appl Clin Med Phys. 2019 Jul;20(7):151-159
pubmed: 31152576
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):42-51
pubmed: 20200105
Br J Hosp Med (Lond). 2006 Mar;67(3):M48-52
pubmed: 16562439

Auteurs

Helle Precht (H)

Health Sciences Research Centre, UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.
Department of Radiology, Kolding, Lillebaelt Hospital, University Hospitals of Southern Denmark, Sygehusvej 24, 6000 Kolding, Denmark.
Department of Regional Health Research, University of Southern Denmark, J.B. Winsløws Vej 19, 3., 5000 Odense C, Denmark.

Claus Bjørn Outzen (CB)

Health Sciences Research Centre, UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.

Martin Weber Kusk (MW)

Department of Radiology and Nuclear Medicine, University Hospital of Southwest Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.

Malene Bisgaard (M)

Health Sciences Research Centre, UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.

Dag Waaler (D)

Department of Health Sciences, Gjøvik, Norwegian University of Science and Technology, Teknologiveien 22, 2803 Gjøvik, Norway.

Articles similaires

Humans Magnetic Resonance Imaging Phantoms, Imaging Infant, Newborn Signal-To-Noise Ratio

Failed radial head arthroplasty treated by removal of the implant.

Juan Ameztoy Gallego, Blanca Diez Sanchez, Afonso Vaquero-Picado et al.
1.00
Humans Male Female Middle Aged Range of Motion, Articular
Humans Shoulder Fractures Tomography, X-Ray Computed Neural Networks, Computer Female
China Cities Humans Economic Development Commerce

Classifications MeSH