Three-dimensional reconstruction image by biplanar stereoradiography reflects pulmonary functional states inadolescent idiopathic scoliosis.
3D reconstructions
Adolescent idiopathic scoliosis
Biplanar stereoradiography
Pulmonary function test
Rib cage parameter
Journal
Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia
ISSN: 1532-2653
Titre abrégé: J Clin Neurosci
Pays: Scotland
ID NLM: 9433352
Informations de publication
Date de publication:
Jun 2021
Jun 2021
Historique:
received:
21
12
2020
revised:
23
03
2021
accepted:
27
03
2021
entrez:
16
5
2021
pubmed:
17
5
2021
medline:
23
6
2021
Statut:
ppublish
Résumé
This study investigated whether the rib cage parameters estimated based on reconstructed three-dimensional (3D) images with biplanar stereoradiography reflect pulmonary functional states in adolescent idiopathic scoliosis (AIS) patients. A total of 67 Lenke type 1 or 2 AIS patients (59 females and 8 males, mean age 14.4 years) were enrolled. All patients underwent preoperative pulmonary functional tests (PFT) and biplanar stereoradiography. Vital capacity (VC) and forced vital capacity (FVC) pulmonary functional data were collected. Rib-cage parameters (maximum thickness, maximum width, thoracic index (TI), rib hump (RH), rib-cage volume (RCV), spinal penetration index (SPI), endothoracic hump ratio (EHR), vertebra-sternum angle (VSA), rib vertebral angle difference (RVAD), and vertebral lateral decentering (VLD)) were quantified from 3D images. Patients were divided into two groups: restrictive lung disorder (RLD) (%FVC < 80%) and non-RLD (%FVC ≥ 80%). The maximum width and RCV were significantly correlated with VC (p < 0.0001), and FVC (p < 0.0001). RH, EHR, and VSA were negatively correlated with %FVC (p < 0.01). TI, SPI, and RVAD were not correlated with any pulmonary parameters. The maximum widths of RLD patients were significantly shorter than those of the non-RLD patients (218.3 mm vs. 229.7 mm, p < 0.01). The RCV of RLD patients was significantly smaller than that of the non-RLD patients (3.94 L vs. 4.49 L, p < 0.0001). The maximum width and RCV measured by 3D images with biplanar stereoradiography reflected pulmonary functional variables in patients with AIS.
Identifiants
pubmed: 33992181
pii: S0967-5868(21)00153-3
doi: 10.1016/j.jocn.2021.03.043
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
178-184Informations de copyright
Copyright © 2021 Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.