SBRT treatment of abdominal and pelvic oligometastatic lymph nodes using ring-mounted Halcyon Linac.


Journal

Journal of applied clinical medical physics
ISSN: 1526-9914
Titre abrégé: J Appl Clin Med Phys
Pays: United States
ID NLM: 101089176

Informations de publication

Date de publication:
Jun 2021
Historique:
revised: 18 03 2021
received: 10 11 2020
accepted: 14 04 2021
pubmed: 26 5 2021
medline: 22 6 2021
entrez: 25 5 2021
Statut: ppublish

Résumé

This work seeks to evaluate the plan quality, treatment delivery efficiency, and accuracy of single-isocenter volumetric modulated arc therapy (VMAT) of abdominal/pelvic oligometastatic lymph nodes (LNs) stereotactic body radiation therapy (SBRT) on Halcyon Linac. After completing the in-house multitarget end-to-end phantom testing and independent dose verification using MD Anderson's single-isocenter/multi-target (lung and spine target inserts) thorax phantom, eight patients with two to three abdominal/pelvic oligometastatic LNs underwent highly conformal single-isocenter VMAT-SBRT treatment using the Halcyon Linac 6MV flattening filter free (FFF) beam. Targets were identified using an Axumin PET/CT scan co-registered with planning CT images and a single-isocenter was placed between/among the targets. Doses between 25 and 36.25 Gy in 5 fractions were delivered. Patients were treated every other day. Plans were calculated in Eclipse with advanced AcurosXB algorithm for heterogeneity corrections. For comparison, Halcyon VMAT-SBRT plans were retrospectively generated for SBRT-dedicated TrueBeam with a 6MV-FFF beam using identical planning geometry and objectives. Target coverage, conformity index (CI), dose to 2 cm away from each target (D2cm) and dose to adjacent organs-at-risk (OAR) were evaluated. Additionally, various treatment delivery parameters including beam-on time were recorded. Phantom measurements showed acceptable spatial accuracy of conebeam CT-guided Halcyon SBRT treatments including compliance with MD Anderson's single-isocenter/multi-targets phantom credentialing results. For patients, the mean isocenter to tumor center distance was 3.4 ± 1.2 cm (range, 1.5-4.8 cm). The mean combined PTV was 18.9 ± 10.9 cc (range, 5.6-39.5 cc). There was no clinically significant difference in dose to LNs, CI, D2cm and maximal doses to OAR between single-isocenter Halcyon and Truebeam VMAT-SBRT plans, although, Halcyon plans provided preferably lower maximal dose to adjacent OAR. Additionally, total monitor units, beam-on time and overall treatment time was lower with Halcyon plans. Halcyon's portal dosimetry demonstrated a high pass rate of 98.1 ± 1.6% for clinical gamma passing criteria of 2%/2 mm. SBRT treatment of abdominal/pelvic oligometastatic LNs with single-isocenter VMAT on Halcyon was dosimetrically equivalent to TrueBeam. Faster treatment delivery to oligometastatic LNs via single-isocenter Halcyon VMAT can improve clinic workflow and patient compliance, potentially reducing intrafraction motion errors for well-suited patients. Clinical follow-up of these patients is ongoing.

Identifiants

pubmed: 34032367
doi: 10.1002/acm2.13268
pmc: PMC8200515
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

162-171

Informations de copyright

© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of American Association of Physicists in Medicine.

Références

J Appl Clin Med Phys. 2014 Jul 08;15(4):4737
pubmed: 25207400
J Appl Clin Med Phys. 2020 Jul;21(7):39-48
pubmed: 32368862
J Appl Clin Med Phys. 2019 Oct;20(10):111-117
pubmed: 31553525
Tumori. 2013 Sep-Oct;99(5):611-6
pubmed: 24362866
Int J Radiat Oncol Biol Phys. 2016 Dec 1;96(5):1078-1086
pubmed: 27742541
J Appl Clin Med Phys. 2019 Jul;20(7):58-67
pubmed: 31183967
Med Phys. 2018 Apr;45(4):e53-e83
pubmed: 29443390
Cancer Invest. 2020 Nov;38(10):599-607
pubmed: 32715780
J Appl Clin Med Phys. 2019 Aug;20(8):47-55
pubmed: 31294923
J Radiat Oncol. 2018;7(4):357-366
pubmed: 30595810
Cureus. 2020 Oct 30;12(10):e11267
pubmed: 33274143
J Radiosurg SBRT. 2017;4(4):265-273
pubmed: 29296451
Radiother Oncol. 2020 May;146:118-125
pubmed: 32146257
Oncologist. 2012;17(8):1100-7
pubmed: 22723509
J Appl Clin Med Phys. 2016 Nov 08;17(6):292-304
pubmed: 27929502
Med Phys. 2017 Jun;44(6):2115-2123
pubmed: 28382761
Phys Med Biol. 2010 Feb 7;55(3):581-98
pubmed: 20057008
Int J Radiat Oncol Biol Phys. 2012 Feb 1;82(2):889-97
pubmed: 21277113
Phys Med Biol. 2010 Aug 21;55(16):N433-40
pubmed: 20679696
Radiat Oncol. 2017 Jun 21;12(1):105
pubmed: 28637480
J Appl Clin Med Phys. 2019 Nov;20(11):111-120
pubmed: 31660682
Med Phys. 2020 Aug;47(8):3669-3674
pubmed: 32367534
Int J Radiat Oncol Biol Phys. 2015 Nov 1;93(3):540-6
pubmed: 26460996
Front Oncol. 2015 Oct 06;5:213
pubmed: 26500888
J Nucl Med. 2018 Apr;59(4):557-567
pubmed: 29301928
Radiother Oncol. 2019 May;134:50-54
pubmed: 31005224
Pract Radiat Oncol. 2016 Nov - Dec;6(6):e291-e298
pubmed: 27345129
Clin Transl Radiat Oncol. 2019 Mar 30;18:46-53
pubmed: 31341975
Adv Radiat Oncol. 2019 Jun 19;4(4):649-658
pubmed: 31673658
Radiat Oncol. 2012 Dec 05;7:204
pubmed: 23216821
J Appl Clin Med Phys. 2019 Apr;20(4):106-114
pubmed: 30889312
Med Phys. 2019 Mar;46(3):1355-1370
pubmed: 30675902
Rep Pract Oncol Radiother. 2015 Nov-Dec;20(6):472-83
pubmed: 26696788
Med Phys. 2010 Aug;37(8):4078-101
pubmed: 20879569
J Appl Clin Med Phys. 2019 Jan;20(1):118-127
pubmed: 30548205
Front Oncol. 2019 Jan 22;9:7
pubmed: 30723702
Radiat Oncol. 2013 Jun 24;8:149
pubmed: 23800024
Technol Cancer Res Treat. 2018 Jan 1;17:1533033818803882
pubmed: 30295172
Phys Med. 2019 Dec;68:112-116
pubmed: 31783220
Int J Radiat Oncol Biol Phys. 2011 Nov 1;81(3):831-8
pubmed: 20800375
Adv Radiat Oncol. 2019 Aug 21;5(1):120-126
pubmed: 32051898
Phys Med Biol. 2017 Nov 14;62(23):L41-L50
pubmed: 29135471
Adv Radiat Oncol. 2020 Jan 28;5(3):482-489
pubmed: 32529144

Auteurs

Damodar Pokhrel (D)

Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, KY, USA.

Aaron Webster (A)

Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, KY, USA.

Joseph Stephen (J)

Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, KY, USA.

William St Clair (W)

Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, KY, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH