An off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time.
CSPAMM
MICSR
cardiac MRI
off-resonance insensitive
tagging
Journal
Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245
Informations de publication
Date de publication:
12 2021
12 2021
Historique:
revised:
25
05
2021
received:
09
04
2021
accepted:
15
06
2021
pubmed:
14
7
2021
medline:
1
2
2022
entrez:
13
7
2021
Statut:
ppublish
Résumé
To develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half of the acquisition time. Phantom and mid-level left ventricle short-axis tagged images were acquired using CSPAMM, ORI-CSPAMM, O-CSPAMM, and the proposed ORI-O-CPAMM sequences to interrogate and compare its behavior under off-resonance effects produced by vegetable oil and subcutaneous and epicardial fat. The images were compared in terms of signal and the capacity to obtain complex difference and MICSR images. Like ORI-CSPAMM, the proposed ORI-O-CSPAMM sequence removed almost completely the off-resonance artifacts produced during the tagging preparation. Tagging grids without DC components were obtained with ORI-O-CSPAMM using complex difference and MICSR from only two complementary images, which reduced the scan time to a half compared to CSPAMM and ORI-CSPAMM. The removal of off-resonance effects and the capacity to obtain MICSR images are advantages of ORI-O-CSPAMM over the O-CSPAMM sequence. We developed a novel and fast tagging sequence designed to remove off-resonance effects during the tagging preparation, and to obtain complex difference and MICSR grids in half of the scan time compared to CSPAMM and ORI-CSPAMM sequences, which could allow its application to clinical protocols.
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
3022-3033Informations de copyright
© 2021 International Society for Magnetic Resonance in Medicine.
Références
Ibrahim E-SH. Myocardial tagging by Cardiovascular Magnetic Resonance: evolution of techniques-pulse sequences, analysis algorithms, and applications. J Cardiovasc Magn Reson. 2011;13:36.
Axel L, Montillo A, Kim D. Tagged magnetic resonance imaging of the heart: a survey. Med Image Anal. 2005;9:376-393.
Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology. 1989;171:841-845.
Fischer SE, McKinnon GC, Maier SE, Boesiger P. Improved myocardial tagging contrast. Magn Reson Med. 1993;30:191-200.
Osman NF, Kerwin WS, McVeigh ER, Prince JL. Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magn Reson Med. 1999;42:1048-1060.
Osman NF, McVeigh ER, Prince JL. Imaging heart motion using harmonic phase MRI. IEEE Trans Med Imaging. 2000;19:186-202.
Tecelão SRR, Zwanenburg JJM, Kuijer JPA, Marcus JT. Extended harmonic phase tracking of myocardial motion: improved coverage of myocardium and its effect on strain results. J Magn Reson Imaging. 2006;23:682-690.
Liu X, Prince JL. Shortest path refinement for motion estimation from tagged MR images. IEEE Trans Med Imaging. 2010;29:1560-1572.
Liu X, Murano E, Stone M, Prince JL. HARP tracking refinement using seeded region growing. 2007 4th IEEE Int. Symp. Biomed. Imaging From Nano to Macro - Proc. 2007, pp. 372-375.
Mella H, Mura J, Wang H, et al. HARP-I: a harmonic phase interpolation method for the estimation of motion from tagged MR images. IEEE Trans Med Imaging. 2021;40:1240-1252.
Arts T, Prinzen FW, Delhaas T, Milles JR, Rossi AC, Clarysse P. Mapping displacement and deformation of the heart with local sine-wave modeling. IEEE Trans Med Imaging. 2010;29:1114-1123.
Wang H, Amini AA. Cardiac deformation analysis using 3D SinMod from 3D CSPAMM tagged MRI. In: Proceedings Volume 8672, Medical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging. Vol. 8672. 2013. p. 86720B.
Wang H, Amini AA. Cardiac motion tracking with multilevel B-splines and SinMod from tagged MRI. In: Weaver JB, Molthen RC, editors. Vol. 7965. International Society for Optics and Photonics; 2011. p. 796520.
Qian Z, Metaxas DN, Axel L. Extraction and tracking of MRI tagging sheets using a 3D gabor filter bank. Annu. Int. Conf. IEEE Eng. Med. Biol. - Proc. 2006, pp. 711-714.
Chen T, Axel L. Using gabor filter banks and temporal-spatial constraints to compute 3D myocardium strain. Annu. Int. Conf. IEEE Eng. Med. Biol. - Proc. 2006, pp. 4755-4758.
NessAiver M, Prince JL. Magnitude image CSPAMM reconstruction (MICSR). Magn Reson Med. 2003;50:331-342.
Fahmy AS, Basha TA, Osman NF. Inherent fat cancellation in complementary spatial modulation of magnetization. Magn Reson Med. 2009;61:234-238.
Reyhan M, Natsuaki Y, Ennis DB. Off-resonance insensitive complementary SPAtial modulation of magnetization (ORI-CSPAMM) for quantification of left ventricular twist. J Magn Reson Imaging. 2014;39:339-345.
Wang H, Kadbi M, Kotys M, et al. Orthogonal CSPAMM (OCSPAMM) MR tagging for imaging ventricular wall motion. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011. pp. 535-538.
Wang H, Kadbi M, Alshaher M, Kotys-Traughber M, Fischer S, Amini A. Cardiac deformation analysis from orthogonal CSPAMM (OCSPAMM) tagged MRI. J Cardiovasc Magn Reson. 2012;14:1-2.
Lefebvre T, Petitclerc L, Hébert M, et al. MRI cine-tagging of cardiac-induced motion for noninvasive staging of liver fibrosis. J Magn Reson Imaging. 2020;51:1570-1580.
Axel L, Dougherty L. Heart wall motion: improved method for spatial modulation of magnetization for MR imaging. Radiology. 1989;172:349-350.
Feinberg DA, Hale JD, Watts JC, Kaufman L, Mark A. Halving MR imaging time by conjugation: demonstration at 3.5 kG. Radiology. 1986;161:527-531.
MacFall JR, Pelc NJ, Vavrek RM. Correction of spatially dependent phase shifts for partial Fourier imaging. Magn Reson Imaging. 1988;6:143-155.
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999;42:952-962.
Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med. 2007;58:1182-1195.
Ahn CB, Kim JH, Cho ZH. High-speed spiral-scan echo planar NMR imaging-I. IEEE Trans Med Imaging. 1986;5:2-7.
Börnert P, Schomberg H, Aldefeld B, Groen J. Improvements in spiral MR imaging. Magma Magn Reson Mater Physics Biol Med. 1999;9:29-41.
Fischer SE, McKinnon GC, Scheidegger MB, Prins W, Meier D, Boesiger P. True myocardial motion tracking. Magn Reson Med. 1994;31:401-413.
Smiseth OA, Torp H, Opdahl A, Haugaa KH, Urheim S. Myocardial strain imaging: how useful is it in clinical decision making? Eur Heart J. 2016;37:1196-1207.
Wu L, Germans T, Güçlü A, Heymans MW, Allaart CP, Van Rossum AC. Feature tracking compared with tissue tagging measurements of segmental strain by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2014;16:10.
Amzulescu MS, De Craene M, Langet H, et al. Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. Eur Hear J Cardiovasc Imaging. 2019;20:605-619.
Aletras AH, Ding S, Balaban RS, Wen H. DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson. 1999;137:247-252.
Osman NF, Sampath S, Atalar E, Prince JL. Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI. Magn Reson Med. 2001;46:324-334.
Neizel M, Lossnitzer D, Korosoglou G, et al. Strain-encoded (SENC) magnetic resonance imaging to evaluate regional heterogeneity of myocardial strain in healthy volunteers: comparison with conventional tagging. J Magn Reson Imaging. 2009;29:99-105.
Bucius P, Erley J, Tanacli R, et al. Comparison of feature tracking, fast-SENC, and myocardial tagging for global and segmental left ventricular strain. ESC Hear Fail. 2020;7:523-532.
Haggerty CM, Kramer SP, Binkley CM, et al. Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice. J Cardiovasc Magn Reson. 2013;15:71.