An asymmetrical whole-body birdcage RF coil without RF shield for hyperpolarized


Journal

Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245

Informations de publication

Date de publication:
12 2021
Historique:
revised: 15 06 2021
received: 23 12 2020
accepted: 15 06 2021
pubmed: 17 7 2021
medline: 1 2 2022
entrez: 16 7 2021
Statut: ppublish

Résumé

This study describes the development and testing of an asymmetrical xenon-129 ( The The asymmetrical birdcage produced a homogeneous A large asymmetrical birdcage for homogenous

Identifiants

pubmed: 34268802
doi: 10.1002/mrm.28915
doi:

Substances chimiques

Protons 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

3373-3381

Subventions

Organisme : Medical Research Council
ID : MR/M008894/1
Pays : United Kingdom

Informations de copyright

© 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Références

Ebert M, Grossmann T, Heil W, et al. Nuclear magnetic resonance imaging with hyperpolarised helium-3. Lancet. 1996;347:1297-1299.
Albert MS, Cates GD, Driehuys B, et al. Biological magnetic resonance imaging using laser-polarized 129Xe. Nature. 1994;370:199-201.
Walkup LL, Thomen RP, Akinyi TG, et al. Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis. Pediatr Radiol. 2016;46:1651-1662.
Lutey BA, Lefrak SS, Woods JC, et al. Hyperpolarized 3 He MR imaging: physiologic monitoring observations and safety considerations in 100 consecutive subjects. Radiology. 2008;248:655-661.
Kirby M, Parraga G. Pulmonary functional imaging using hyperpolarized noble gas MRI. Six years of start-up experience at a single site. Acad Radiol. 2013;20:1344-1356.
Woodhouse N, Wild JM, van Beek EJR, Hoggard N, Barker N, Taylor CJ. Assessment of hyperpolarized 3 He lung MRI for regional evaluation of interventional therapy: a pilot study in pediatric cystic fibrosis. J Magn Reson Imaging. 2009;30:981-988.
Swift AJ, Wild JM, Fichele S, et al. Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI. Eur J Radiol. 2005;54:352-358.
van Beek EJR, Wild JM, Kauczor H-U, Schreiber W, Mugler JP, de Lange EE. Functional MRI of the lung using hyperpolarized 3-helium gas. J Magn Reson Imaging. 2004;20:540-554.
Xu X, Norquay G, Parnell SR, et al. Hyperpolarized 129 Xe gas lung MRI-SNR and T2* comparisons at 1.5 T and 3 T. Magn Reson Med. 2012;68:1900-1904.
Narazaki M, Kimura A, Wakayama T, Imai H, Fujiwara H. Origin of dissolved-phase hyperpolarized 129Xe signal in the mouse chest based on experimental evidence from extensive magnetic resonance measurements. Magn Reson Med Sci. 2011;10:149-154.
Kaushik SS, Freeman MS, Cleveland ZI, et al. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging. J Appl Physiol. 2013;115:850-860.
Cleveland ZI, Cofer GP, Metz G, et al. Hyperpolarized 129Xe MR imaging of alveolar gas uptake in humans. PLoS One. 2010;5:e12192.
Wang JM, Robertson SH, Wang Z, et al. Using hyperpolarized 129Xe MRI to quantify regional gas transfer in idiopathic pulmonary fibrosis. Thorax. 2018;73:21-28.
Chacon Caldera J, Maunder A, Rao M, et al. Dynamic MRI of hyperpolarized Xenon-129 uptake in the human kidney using a dedicated transmission-only-reception-only array at 3 Tesla. In Proceedings of the 26th Annual Meeting of ISMRM, Paris, France, 2018. Abstract 4470.
Chacon-Caldera J, Maunder A, Rao M, et al. Dissolved hyperpolarized xenon-129 MRI in human kidneys. Magn Reson Med. 2020;83:262-270.
Miller G, Cates G, Keder D, et al. Dynamic spectroscopy of dissolved-phase xenon-129 in the human kidney. In Proceedings of the 25th Annual Meeting of ISMRM, Honolulu, HI, 2017. Abstract 1182.
Rao M, Stewart NJ, Norquay G, Griffiths PD, Wild JM. High resolution spectroscopy and chemical shift imaging of hyperpolarized 129 Xe dissolved in the human brain in vivo at 1.5 Tesla. Magn Reson Med. 2016;75:2227-2234.
Rao M, Stewart NJ, Griffiths PD, Norquay G, Wild JM. Imaging human brain perfusion with inhaled hyperpolarized 129Xe MR imaging. Radiology. 2018;286:659-665. doi: 10.1148/radiol.2017162881.
Hane F, Li T, Plata J-A, Hassan A, Granberg K, Albert M. Inhaled xenon washout as a biomarker of Alzheimer’s disease. Diagnostics (Basel). 2018;8:41.
De Zanche N, Chhina N, Teh K, Randell C, Pruessmann KP, Wild JM. Asymmetric quadrature split birdcage coil for hyperpolarized 3He lung MRI at 1.5T. Magn Reson Med. 2008;60:431-438.
Wetterling F, Corteville DM, Kalayciyan R, et al. Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer. Phys Med Biol. 2012;57:4555-4567.
Farag A, Peterson JC, Szekeres T, et al. Unshielded asymmetric transmit-only and endorectal receive-only radiofrequency coil for 23Na MRI of the prostate at 3 Tesla. J Magn Reson Imaging. 2015;42:436-445.
Deppe MH, Parra-Robles J, Marshall H, Lanz T, Wild JM. A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T. Magn Reson Med. 2011;66:1788-1797.
Dregely I, Ruset IC, Wiggins G, et al. 32-channel phased-array receive with asymmetric birdcage transmit coil for hyperpolarized xenon-129 lung imaging. Magn Reson Med. 2013;70:576-583.
De Zanche N, Chhina N, Teh K, Randell C, Wild JM. Optimized asymmetric quadrature split birdcage coil for hyperpolarized 3 He lung MRI at 1.5T. In Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany, 2007. p. 240.
Collins CM, Smith MB. Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med. 2001;45:692-699.
Horn FC, Rao M, Stewart NJ, Wild JM. Multiple breath washout of hyperpolarized 129 Xe and 3 He in human lungs with three-dimensional balanced steady-state free-precession imaging. Magn Reson Med. 2017;77:2288-2295.
Walker TG, Happer W. Spin-exchange optical pumping of noble-gas nuclei. Rev Mod Phys. 1997;69:629-642.
Norquay G, Collier GJ, Rao M, Stewart NJ, Wild JM. 129Xe-Rb spin-exchange optical pumping with high photon efficiency. Phys Rev Lett. 2018;15:121.
Deoni SCL. High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI). J Magn Reson Imaging. 2007;26:1106-1111.
Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med. 1995;34:910-914.
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med. 1990;16:192-225.
McKenzie CA, Yeh EN, Ohliger MA, Price MD, Sodickson DK. Self-calibrating parallel imaging with automatic coil sensitivity extraction. Magn Reson Med. 2002;47:529-538.
Weiger M, Pruessmann KP, Boesiger P. 2D SENSE for faster 3D MRI. MAGMA. 2002;14:10-19.
Wang J, Mao W, Qiu M, Smith MB, Constable RT. Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities. Magn Reson Med. 2006;56:463-468.
Wild JM, Teh K, Woodhouse N, et al. Steady-state free precession with hyperpolarized 3He: experiments and theory. J Magn Reson. 2006;183:13-24.
Bieri O, Scheffler K. Fundamentals of balanced steady state free precession MRI. J Magn Reson Imaging. 2013;38:2-11.
Mugler JP, Altes TA. Hyperpolarized 129 Xe MRI of the human lung. J Magn Reson Imaging. 2013;37:313-331.
Farag A, Wang J, Ouriadov A, Parraga G, Santyr G. Unshielded and asymmetric RF transmit coil for hyperpolarized 129Xe human lung imaging at 3.0 T. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 1361.
International Electrotechnical Commission (IEC). IEC 60601-2-33:2010 Medical Electrical Equipment - Part 2-33: Particular Requirements for the Basic Safety and Essential Performance of Magnetic Resonance Equipment for Medical Diagnosis. https://webstore.iec.ch/publication/2647. Accessed October 31, 2020.
Rao M, Robb F, Wild JM. Dedicated receiver array coil for 1H lung imaging with same-breath acquisition of hyperpolarized 3He and 129Xe gas. Magn Reson Med. 2015;74:291-299.

Auteurs

Claudio Puddu (C)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Madhwesha Rao (M)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Xiaojun Xu (X)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Martin H Deppe (MH)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Guilhem Collier (G)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Adam Maunder (A)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Ho-Fung Chan (HF)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Nicola De Zanche (N)

Department of Medical Physics, Cross Cancer Institute and University of Alberta, Alberta, Canada.

Fraser Robb (F)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
GE Healthcare, Aurora, Ohio, USA.

Jim M Wild (JM)

POLARIS, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.

Articles similaires

Humans Ketamine Propofol Pulmonary Atelectasis Female
Humans Magnetic Resonance Imaging Phantoms, Imaging Infant, Newborn Signal-To-Noise Ratio
1.00
Humans Magnetic Resonance Imaging Brain Infant, Newborn Infant, Premature
Respiratory Syncytial Virus Infections Humans Animals Mice STAT3 Transcription Factor

Classifications MeSH