An Electro-Oculogram Based Vision System for Grasp Assistive Devices-A Proof of Concept Study.
artificial vision
brain–computer interface
electrooculogram
grasp assistive device
inexpensive imaging
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
01 Jul 2021
01 Jul 2021
Historique:
received:
16
02
2021
revised:
06
05
2021
accepted:
12
05
2021
entrez:
20
7
2021
pubmed:
21
7
2021
medline:
22
7
2021
Statut:
epublish
Résumé
Humans typically fixate on objects before moving their arm to grasp the object. Patients with ALS disorder can also select the object with their intact eye movement, but are unable to move their limb due to the loss of voluntary muscle control. Though several research works have already achieved success in generating the correct grasp type from their brain measurement, we are still searching for fine controll over an object with a grasp assistive device (orthosis/exoskeleton/robotic arm). Object orientation and object width are two important parameters for controlling the wrist angle and the grasp aperture of the assistive device to replicate a human-like stable grasp. Vision systems are already evolved to measure the geometrical attributes of the object to control the grasp with a prosthetic hand. However, most of the existing vision systems are integrated with electromyography and require some amount of voluntary muscle movement to control the vision system. Due to that reason, those systems are not beneficial for the users with brain-controlled assistive devices. Here, we implemented a vision system which can be controlled through the human gaze. We measured the vertical and horizontal electrooculogram signals and controlled the pan and tilt of a cap-mounted webcam to keep the object of interest in focus and at the centre of the picture. A simple 'signature' extraction procedure was also utilized to reduce the algorithmic complexity and system storage capacity. The developed device has been tested with ten healthy participants. We approximated the object orientation and the size of the object and determined an appropriate wrist orientation angle and the grasp aperture size within 22 ms. The combined accuracy exceeded 75%. The integration of the proposed system with the brain-controlled grasp assistive device and increasing the number of grasps can offer more natural manoeuvring in grasp for ALS patients.
Identifiants
pubmed: 34282770
pii: s21134515
doi: 10.3390/s21134515
pmc: PMC8271916
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Engineering and Physical Sciences Research Council
ID : EP/M025977/1
Organisme : Engineering and Physical Sciences Research Council
ID : EP/R004242/1
Organisme : INSPIRE Fellowship, Ministry of Science and Technology, Government of India.
ID : DST/ INSPIRE Fellow-432ship/ 2014/[249]
Références
J Neural Eng. 2017 Jun;14(3):036025
pubmed: 28467317
J Vis. 2012 Jan 04;12(1):
pubmed: 22219310
IEEE Trans Biomed Eng. 2015 Nov;62(11):2576-2587
pubmed: 26111386
Artif Organs. 2011 Jan;35(1):37-48
pubmed: 20618232
J Neural Eng. 2015 Dec;12(6):066022
pubmed: 26529274
IEEE Trans Neural Syst Rehabil Eng. 2020 Sep;28(9):2090-2099
pubmed: 32746315
Hum Mov Sci. 2002 Sep;21(3):349-76
pubmed: 12381393
Front Neurosci. 2015 Apr 09;9:121
pubmed: 25914616
J Neuroeng Rehabil. 2010 Aug 23;7:42
pubmed: 20731834
J Neural Eng. 2014 Aug;11(4):046001
pubmed: 24891493
J Neural Eng. 2018 Oct;15(5):056028
pubmed: 30063469
J Neural Eng. 2010 Aug;7(4):046002
pubmed: 20489239
Hum Mov Sci. 2018 Oct;61:189-196
pubmed: 30170261
Acta Neuropathol. 2013 Jan;125(1):95-109
pubmed: 23143228
Medicine (Baltimore). 2017 Mar;96(13):e6444
pubmed: 28353574
Ergonomics. 1998 May;41(5):670-7
pubmed: 9613227
J Exp Psychol Hum Percept Perform. 1990 May;16(2):248-67
pubmed: 2142197
Med Biol Eng Comput. 2018 Nov;56(11):2095-2107
pubmed: 29777505